| 12725.1 |
26 Ga. Perma-Lok |
26 Ga. Perma-Lok over 15/32" plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-63.5PSF Other: -63.5 psf @ 5 3/16” O.C. fastener Spacing. Install per manufacturer's details. Not for use in HVHZ Zones. |
Installation Instructions FL12725_R4_II_12725.1 Perma-Lok 26 ga. over 15-32 Plywood Roof_sealed.pdf Verified By: Johnathan E Green, P.E. 88223 Created by Independent Third Party: Yes Evaluation Reports FL12725_R4_AE_12725.1 Perma-Lok 26 ga. over 15-32 Plywood Roof_sealed.pdf Created by Independent Third Party: Yes |
|
|
| 12725.2 |
26 Ga. Residential |
26 Ga. Residential over 15/32" Plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-146.0PSF Other: -69.25 psf @ 24" o.c. fastener spacing. -146.0 psf @ 12" o.c. fastener spacing. Install per manufacturer's details. Not for use in HVHZ Zones. |
Installation Instructions FL12725_R4_II_12725.2 26 Ga. Residential Panel over 15-32Plywood NON HVHZ_sealed.pdf Verified By: Johnathan E Green, P.E. 88223 Created by Independent Third Party: Yes Evaluation Reports FL12725_R4_AE_12725.2 26 Ga. Residential Panel over 15-32Plywood NON HVHZ_sealed.pdf Created by Independent Third Party: Yes |
|
|
| 12725.3 |
26 Ga. Residential |
26 Ga. Residential over 1x4 Wood Purlins |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-123.5PSF Other: -109.25 psf @ 24" o.c. fastener spacing. -123.5 psf @ 24" o.c. fastener spacing. Install per manufacuturers details. Not for use in HVHZ Zones. |
Installation Instructions FL12725_R4_II_12725.3 26 Ga. Residential Panel over 1x4 NON HVHZ Roof_sealed.pdf Verified By: Johnathan E Green, P.E. 88223 Created by Independent Third Party: Yes Evaluation Reports FL12725_R4_AE_12725.3 26 Ga. Residential Panel over 1x4 NON HVHZ Roof_sealed.pdf Created by Independent Third Party: Yes |
|
|
| 12725.4 |
29 Ga. Residential |
29 Ga. Residential over 15/32" plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-146.0PSF Other: -71.75 psf @ 24” o.c. fastener spacing.-146.0 psf @ 12” o.c. fastener spacing. Install per manufacturer's details. Not for use in HVHZ Zones. |
Installation Instructions FL12725_R4_II_12725.4 29 Ga. Residential Panel over .5 Plywood NON HVHZ_sealed.pdf Verified By: Johnathan E Green, P.E. 88223 Created by Independent Third Party: Yes Evaluation Reports FL12725_R4_AE_12725.4 29 Ga. Residential Panel over .5 Plywood NON HVHZ_sealed.pdf Created by Independent Third Party: Yes |
|
|
| 12725.5 |
29 Ga. Residential |
29 Ga. Residential over
1 x 4 Wood Purlins |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-123.5PSF Other: -76.75 psf @ 24” o.c. fastener spacing. -123.5 psf @ 24" o.c. fastener spacing. Install per manufacturer's details. Not for HVHZ Zones. |
Installation Instructions FL12725_R4_II_12725.5 29 Ga. Residential Panel over 1x4 NON HVHZ_sealed.pdf Verified By: Johnathan E Green, P.E. 88223 Created by Independent Third Party: Yes Evaluation Reports FL12725_R4_AE_12725.5 29 Ga. Residential Panel over 1x4 NON HVHZ_sealed.pdf Created by Independent Third Party: Yes |