| 12786.1 |
8211 ALUM CLAD AWNING (60x36) WITH CASEMENT PICTURE (60"x60") STACKED |
LC-PG55-1511X2413 (60X95) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +55/-55 Other: Awning is 3/4" overall insulated glass comprised of two lites of 3mm (1/8") annealed glass; picture unit is 3/4" O.A. insulated glass comprised of two lites of 3.9mm (5/32") annealed glass. Glass complies with E1300 requirements. |
Certification Agency Certificate FL12786_R12_C_CAC_8211 449-H-017.49 50 51 52.pdf Quality Assurance Contract Expiration Date 06/01/2033 Installation Instructions FL12786_R12_II_85-7807-07 rev 1.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 12786.2 |
8211 ALUM CLAD AWNING MULL |
LC-PG50-3029X1511 (119X60) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +50/-50 Other: 3/4" Overall Insul Glass; produced with two lites of 3mm (1/8") annealed glass. Glass complies with ASTM E1300. |
Certification Agency Certificate FL12786_R12_C_CAC_8211 449-H-017.45 .46 .47 .48.pdf Quality Assurance Contract Expiration Date 06/20/2033 Installation Instructions FL12786_R12_II_85-7808-07 rev 1.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 12786.3 |
8211 ALUM CLAD AWNING SINGLE |
LC-PG50-1511X1511 (60X60) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +50/-50 Other: 3/4" Overall Insul Glass; produced with two lites of 3mm (1/8") annealed glass. Glass complies with ASTM E1300. |
Certification Agency Certificate FL12786_R12_C_CAC_8211 449-H-017.45 .46 .47 .48.pdf Quality Assurance Contract Expiration Date 06/20/2033 Installation Instructions FL12786_R12_II_85-7808-07 rev 1.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 12786.4 |
8211 ALUM CLAD AWNING SINGLE |
LC-PG55-1511X889 (60X36) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +55/-55 Other: 3/4" overall insulated glass comprised of two lites of 3mm (1/8") annealed glass. Glass complies with E1300 requirements. |
Certification Agency Certificate FL12786_R12_C_CAC_8211 449-H-017.49 50 51 52.pdf Quality Assurance Contract Expiration Date 06/01/2033 Installation Instructions FL12786_R12_II_85-7807-07 rev 1.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 12786.5 |
8211 ALUM CLAD AWNING SINGLE w/corner drives |
LC-PG40-1816X1816 (72X72) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +40/-40 Other: 3/4" overall insulated glass comprised of two lites of (3/16") annealed glass. Glass complies with E1300 requirements. |
Certification Agency Certificate FL12786_R12_C_CAC_8211 449-H-017.53 .54.pdf Quality Assurance Contract Expiration Date 07/15/2034 Installation Instructions FL12786_R12_II_85-7808-08 rev 1.PDF Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |