| 6364.1 |
26 Ga. Express Rib |
26 Ga. Express Rib over 15/32" APA plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-146.0psf Other: Type 1: -86.75 psf @ 2'-0" o.c. fastener pattern. Type 2: -146.0 psf @ 1'-0" o.c. fastener pattern. Install per manufacturers details and in compliance with FBC 2020.
Not for use in HVHZ Zones. |
Installation Instructions FL6364_R5_II_SS 2020 FL 6364 BMP METAL PRODUCTS BESSEMER.pdf Verified By: Locke Bowden, P.E. 15626 Created by Independent Third Party: Yes Evaluation Reports FL6364_R5_AE_SS 2020 FL 6364 BMP METAL PRODUCTS BESSEMER.pdf Created by Independent Third Party: Yes |
|
|
| 6364.2 |
26GA PBR Roof Panel |
26GA PBR Roof Panel over 15/32" APA Plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-56.75 Other: -56.75 PSF 9"-9"-9"-9" fastening pattern @ 24" o.c. Type 1 7"-5"-7"-5"-7"-5" fastening pattern @ 12" o.c. at eave and valley Type 2 |
Installation Instructions FL6364_R5_II_SS 2020 FL 6364 BMP METAL PRODUCTS BESSEMER.pdf Verified By: Locke Bowden, P.E. 15262 Created by Independent Third Party: Yes Evaluation Reports FL6364_R5_AE_SS 2020 FL 6364 BMP METAL PRODUCTS BESSEMER.pdf Created by Independent Third Party: Yes |