| 30297.1 |
EHV-550D Hurricane Louver |
5" Deep Vertical Blade Louver, Extruded Aluminum, High Velocity Wind Driven Rain Resistant, Impact & Pressure Resistant |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +100/-100 Other: Allowable Stress Design (ASD). Rated for AMCA 540 Enhanced Protection Missile Impact Level E (80 fps) without TAS 203 Cyclic. Rated for TAS 201 Basic Missile Impact Level D (50 fps) with TAS 203 Cyclic. Passed AMCA 550 with Blades Fully Open. Approved for installation into Cracked Concrete Substrate. Substrates Include: Cracked Concrete, Grout Filled CMU, Steel, Aluminum & Wood. |
Installation Instructions FL30297_R3_II_FPA 30297 EHV-550D PE Eval Report 2024-01-08.pdf Verified By: Wayne K Helmila 59092 Created by Independent Third Party: Yes Evaluation Reports FL30297_R3_AE_FPA 30297 EHV-550D PE Eval Report 2024-01-08.pdf Created by Independent Third Party: Yes |