Florida Building Code Online
Florida Department of Business & Professional Regulation
myFlorida Logo Town Graphic
DBPR Home Button About DBPR Button DBPR Divisions Button Contact DBPR Button
Florida Department of Business & Professional Regulation
Office of the Secretary
Product Approval
USER: Public User
 
Product Approval Menu > Application Detail
 
FL # FL46813
Application Type New
Code Version 2023
Application Status Approved
 
Comments
Archived
 
Product Manufacturer Horizon Structural Systems, Inc.
Address/Phone/Email 1659 W State Hwy 46
New Braunfels, TX
(414) 305-0488
dljohnson.123@gmail.com
 
Authorized Signature Johnson Dennis
dljohnson.123@gmail.com
 
Technical Representative
Address/Phone/Email
 
Quality Assurance Representative
Address/Phone/Email
 
Category Panel Walls
Subcategory Siding
 
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Evaluation Report - Hardcopy Received
 
Florida Engineer or Architect Name who developed the Evaluation Report Keith Joyce
Florida License PE-59081
Quality Assurance Entity Farabaugh Engineering and Testing, LLC
Quality Assurance Contract Expiration Date 08/31/2029
Validated By Dennis Johnson, PE
  Validation Checklist - Hardcopy Received
 
Certificate of Independence FL46813_R0_COI_Certificate of Independence (Horizon).pdf
 
Referenced Standard and Year (of Standard)
 
Equivalence of Product Standards
Certified By

 
Sections from the Code
1404.5
1405.2
 
 
 
Product Approval Method Method 2 Option B
 
Date Submitted 06/12/2024
Date Validated 07/03/2024
Date Pending FBC Approval 07/04/2024
Date Approved 08/13/2024
 
Summary of Products
FL # Model, Number or Name Description
46813.1 7.2 Wall Panel 1. 26 ga 7.2 W/ 14.4" fastener sp. 2. 26 ga 7.2 W/ 7.2" fastener sp. 3. 24 ga 7.2 W/ 14.4" fastener sp. 4. 24 ga 7.2 W/ 7.2" fastener sp. 5. 22 ga 7.2 W/ 14.4" fastener sp. 6. 22 ga 7.2 W/ 7.2" fastener sp.
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +55.0/-34.1
 Other: +55.0 / -34.1 psf allowable load for 26 ga 7.2 panel W/ 14.4" fastener spacing on 5'-0" support spacing. See Evaluation Report for other gauges, fastener spacings and allowable span loads.
Installation Instructions
 FL46813_R0_II_7.2 Panel Installation Details.pdf
 Verified By: Keith Joyce 59081
 Created by Independent Third Party: No
Evaluation Reports
 FL46813_R0_AE_7.2 Panel Wall Evaluation Report.pdf
 Created by Independent Third Party: Yes
46813.2 HL-12 Wall Panel 1. 26 ga HL-12 Panel 2. 24 ga HL-12 Panel 3. 22 ga HL-12 Panel
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +8.5/-5.4
 Other: +8.5 / -5.4 psf allowable load on 5'-0" support spacing. See Evaluation Report for other gauges and support spacing allowable span loads.
Installation Instructions
 FL46813_R0_II_HL-12 Panel Installation Drawings.pdf
 Verified By: Keith Joyce 59081
 Created by Independent Third Party: No
Evaluation Reports
 FL46813_R0_AE_HL-12 Wall Evaluation Report.pdf
 Created by Independent Third Party: Yes
46813.3 HW-120 1. 26 ga HW-120 Panel 2. 24 ga HW-120 Panel 3. 22 ga HW-120 Panel
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +11.3/-9.4
 Other: +11.3 / -9.4 psf allowable load for 26 gauge HW-120 Panel with support spacing at 5'-0". See Evaluation Report for other gauges and support spacing allowabl span loads.
Installation Instructions
 FL46813_R0_II_HW-120 Panel Installation Details.pdf
 Verified By: Keith Joyce 59081
 Created by Independent Third Party: No
Evaluation Reports
 FL46813_R0_AE_HW-120 Wall Evaluation Report.pdf
 Created by Independent Third Party: Yes
46813.4 PBC Wall Panel 1. 26 ga PBC W/ 10.68" Fastener Sp. 2. 26 ga PBC W/5.34" Fastener Sp. 3. 24 ga PBC W/ 10.68" Fastener Sp. 4. 24 ga PBC W/5.34" Fastener Sp. 5. 22 ga PBC W/ 10.68" Fastener Sp. 6. 22 ga PBC W/5.34" Fastener Sp.
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +41.0/-39.4
 Other: +41.0 / -39.4 psf allowable load for 26 gauge W/ 10.68" fastener spacing. See Evaluation Report for other gauges and fastener spacing allowable loads.
Installation Instructions
 FL46813_R0_II_PBC Panel Installation Drawings.pdf
 Verified By: Keith Joyce 59081
 Created by Independent Third Party: No
Evaluation Reports
 FL46813_R0_AE_PBC Wall Evaluation Report.pdf
 Created by Independent Third Party: Yes
46813.5 PBD Wall Panel 1. 26 ga PBD W/ 10.68" Fastener Sp. 2. 26 ga PBD W/ 5.34" Fastener Sp. 3. 24 ga PBD W/ 10.68" Fastener Sp. 4. 24 ga PBD W/ 5.34" Fastener Sp. 5. 22 ga PBD W/ 10.68" Fastener Sp. 6. 22 ga PBD W/ 5.34" Fastener Sp.
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +16.1/-16.1
 Other: +16.1 / -16.1 psf allowable load for 26 ga PBD panel W/ 10.68" fastener spacing at 5'-0" spans. See Evaluation Report for other gauge, fastener and span loads.
Installation Instructions
 FL46813_R0_II_PBD Installation Details.pdf
 Verified By: Keith Joyce 59081
 Created by Independent Third Party: No
Evaluation Reports
 FL46813_R0_AE_PBD Wall Evaluation Report.pdf
 Created by Independent Third Party: Yes
46813.6 PBR Wall Panel 1. 26 ga PBR W/12-12 Fastener Sp. 2. 26 ga PBR W/ 5-7-5 Fastener Sp. 3. 24 ga PBR W/ 12-12 Fastener Sp. 4. 24 ga PBR W/ 5-7-5 Fastener Sp. 5. 22 ga PBR W/ 12-12 Fastener Sp. 6. 22 ga PBR W/ 5-7-5 Fastener Sp.
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +31.1/-30.4
 Other: +31.1 / -30.4 psf allowable load for 26 gauge PBR for 5-'0" span with 12-12 fastener spacing. See evaluation report for other span load, gauge and fastener spacing allowable loads.
Installation Instructions
 FL46813_R0_II_PBR Installation Details.pdf
 Verified By: Keith Joyce 59081
 Created by Independent Third Party: No
Evaluation Reports
 FL46813_R0_AE_PBR Wall Evaluation Report.pdf
 Created by Independent Third Party: Yes
46813.7 PBU Wall Panel 1. 26 ga PBU W/ 12-12 Fastener Sp. 2. 26 ga PBU W/ 5-7-5 Fastener Sp. 3. 24 ga PBU W/ 12-12 Fastener Sp. 4. 24 ga PBU W/ 5-7-5 Fastener Sp. 5. 22 ga PBU W/ 12-12 Fastener Sp. 6. 22 ga PBU W/5-7-5 Fastener Sp.
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +30.4/-30.5
 Other: +30.4 / -30.5 psf allowable load for 26 ga PBU with 12-12 Fastener Spacing. See Evaluation report for other gauges and fastener spacing allowable loads.
Installation Instructions
 FL46813_R0_II_PBU Installation Details.pdf
 Verified By: Keith Joyce 59081
 Created by Independent Third Party: No
Evaluation Reports
 FL46813_R0_AE_PBU Wall Evaluation Report.pdf
 Created by Independent Third Party: Yes
 
Back   Next
 
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
Product Approval Accepts:
Visa Mastercard Discover eCheck Amex