| 46813.1 |
7.2 Wall Panel |
1. 26 ga 7.2 W/ 14.4" fastener sp.
2. 26 ga 7.2 W/ 7.2" fastener sp.
3. 24 ga 7.2 W/ 14.4" fastener sp.
4. 24 ga 7.2 W/ 7.2" fastener sp.
5. 22 ga 7.2 W/ 14.4" fastener sp.
6. 22 ga 7.2 W/ 7.2" fastener sp. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +55.0/-34.1 Other: +55.0 / -34.1 psf allowable load for 26 ga 7.2 panel W/ 14.4" fastener spacing on 5'-0" support spacing. See Evaluation Report for other gauges, fastener spacings and allowable span loads. |
Installation Instructions FL46813_R0_II_7.2 Panel Installation Details.pdf Verified By: Keith Joyce 59081 Created by Independent Third Party: No Evaluation Reports FL46813_R0_AE_7.2 Panel Wall Evaluation Report.pdf Created by Independent Third Party: Yes |
|
|
| 46813.2 |
HL-12 Wall Panel |
1. 26 ga HL-12 Panel
2. 24 ga HL-12 Panel
3. 22 ga HL-12 Panel |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +8.5/-5.4 Other: +8.5 / -5.4 psf allowable load on 5'-0" support spacing. See Evaluation Report for other gauges and support spacing allowable span loads. |
Installation Instructions FL46813_R0_II_HL-12 Panel Installation Drawings.pdf Verified By: Keith Joyce 59081 Created by Independent Third Party: No Evaluation Reports FL46813_R0_AE_HL-12 Wall Evaluation Report.pdf Created by Independent Third Party: Yes |
|
|
| 46813.3 |
HW-120 |
1. 26 ga HW-120 Panel
2. 24 ga HW-120 Panel
3. 22 ga HW-120 Panel |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +11.3/-9.4 Other: +11.3 / -9.4 psf allowable load for 26 gauge HW-120 Panel with support spacing at 5'-0". See Evaluation Report for other gauges and support spacing allowabl span loads. |
Installation Instructions FL46813_R0_II_HW-120 Panel Installation Details.pdf Verified By: Keith Joyce 59081 Created by Independent Third Party: No Evaluation Reports FL46813_R0_AE_HW-120 Wall Evaluation Report.pdf Created by Independent Third Party: Yes |
|
|
| 46813.4 |
PBC Wall Panel |
1. 26 ga PBC W/ 10.68" Fastener Sp.
2. 26 ga PBC W/5.34" Fastener Sp.
3. 24 ga PBC W/ 10.68" Fastener Sp.
4. 24 ga PBC W/5.34" Fastener Sp.
5. 22 ga PBC W/ 10.68" Fastener Sp.
6. 22 ga PBC W/5.34" Fastener Sp. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +41.0/-39.4 Other: +41.0 / -39.4 psf allowable load for 26 gauge W/ 10.68" fastener spacing. See Evaluation Report for other gauges and fastener spacing allowable loads. |
Installation Instructions FL46813_R0_II_PBC Panel Installation Drawings.pdf Verified By: Keith Joyce 59081 Created by Independent Third Party: No Evaluation Reports FL46813_R0_AE_PBC Wall Evaluation Report.pdf Created by Independent Third Party: Yes |
|
|
| 46813.5 |
PBD Wall Panel |
1. 26 ga PBD W/ 10.68" Fastener Sp.
2. 26 ga PBD W/ 5.34" Fastener Sp.
3. 24 ga PBD W/ 10.68" Fastener Sp.
4. 24 ga PBD W/ 5.34" Fastener Sp.
5. 22 ga PBD W/ 10.68" Fastener Sp.
6. 22 ga PBD W/ 5.34" Fastener Sp. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +16.1/-16.1 Other: +16.1 / -16.1 psf allowable load for 26 ga PBD panel W/ 10.68" fastener spacing at 5'-0" spans. See Evaluation Report for other gauge, fastener and span loads. |
Installation Instructions FL46813_R0_II_PBD Installation Details.pdf Verified By: Keith Joyce 59081 Created by Independent Third Party: No Evaluation Reports FL46813_R0_AE_PBD Wall Evaluation Report.pdf Created by Independent Third Party: Yes |
|
|
| 46813.6 |
PBR Wall Panel |
1. 26 ga PBR W/12-12 Fastener Sp.
2. 26 ga PBR W/ 5-7-5 Fastener Sp.
3. 24 ga PBR W/ 12-12 Fastener Sp.
4. 24 ga PBR W/ 5-7-5 Fastener Sp.
5. 22 ga PBR W/ 12-12 Fastener Sp.
6. 22 ga PBR W/ 5-7-5 Fastener Sp. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +31.1/-30.4 Other: +31.1 / -30.4 psf allowable load for 26 gauge PBR for 5-'0" span with 12-12 fastener spacing. See evaluation report for other span load, gauge and fastener spacing allowable loads. |
Installation Instructions FL46813_R0_II_PBR Installation Details.pdf Verified By: Keith Joyce 59081 Created by Independent Third Party: No Evaluation Reports FL46813_R0_AE_PBR Wall Evaluation Report.pdf Created by Independent Third Party: Yes |
|
|
| 46813.7 |
PBU Wall Panel |
1. 26 ga PBU W/ 12-12 Fastener Sp.
2. 26 ga PBU W/ 5-7-5 Fastener Sp.
3. 24 ga PBU W/ 12-12 Fastener Sp.
4. 24 ga PBU W/ 5-7-5 Fastener Sp.
5. 22 ga PBU W/ 12-12 Fastener Sp.
6. 22 ga PBU W/5-7-5 Fastener Sp. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +30.4/-30.5 Other: +30.4 / -30.5 psf allowable load for 26 ga PBU with 12-12 Fastener Spacing. See Evaluation report for other gauges and fastener spacing allowable loads. |
Installation Instructions FL46813_R0_II_PBU Installation Details.pdf Verified By: Keith Joyce 59081 Created by Independent Third Party: No Evaluation Reports FL46813_R0_AE_PBU Wall Evaluation Report.pdf Created by Independent Third Party: Yes |