| 46831.1 |
a. TRIMLITE Fiberglass Door |
6'8 "Non-Impact" Opaque Fiberglass Single Door - Inswing/Outswing (X – Configuration) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: N/A Other: See INST 46831.1 for Design Pressure Ratings, any additional use limitations, installation instructions and product particulars. Fasteners & connectors in areas within 3000 ft (914 m) of a saltwater coastline shall comply with FBC Sections 1711.1 or R332.1. |
Installation Instructions FL46831_R2_II_(d) Inst 46831.1.pdf Verified By: Lyndon F. Schmidt, P.E. 43409 Created by Independent Third Party: Yes Evaluation Reports FL46831_R2_AE_(d) Eval 46831.1.pdf Created by Independent Third Party: Yes |
|
|
| 46831.2 |
b. TRIMLITE Fiberglass Door |
6'8 "Non-Impact" Opaque Fiberglass Single Door with Sidelite(s) - Boxed Construction - Inswing/Outswing (OX or XO, OXO – Configurations) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: N/A Other: See INST 46831.2 for Design Pressure Ratings, any additional use limitations, installation instructions and product particulars. Fasteners & connectors in areas within 3000 ft (914 m) of a saltwater coastline shall comply with FBC Sections 1711.1 or R332.1. |
Installation Instructions FL46831_R2_II_(d) Inst 46831.2.pdf Verified By: Lyndon F. Schmidt, P.E. 43409 Created by Independent Third Party: Yes Evaluation Reports FL46831_R2_AE_(d) Eval 46831.2.pdf Created by Independent Third Party: Yes |
|
|
| 46831.3 |
c. TRIMLITE Fiberglass Door |
6'8 "Non-Impact" Opaque Fiberglass Double Door - Inswing/Outswing (XX – Configuration) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: N/A Other: See INST 46831.3 for Design Pressure Ratings, any additional use limitations, installation instructions and product particulars. Fasteners & connectors in areas within 3000 ft (914 m) of a saltwater coastline shall comply with FBC Sections 1711.1 or R332.1. |
Installation Instructions FL46831_R2_II_(d) Inst 46831.3.pdf Verified By: Lyndon F. Schmidt, P.E. 43409 Created by Independent Third Party: Yes Evaluation Reports FL46831_R2_AE_(d) Eval 46831.3.pdf Created by Independent Third Party: Yes |
|
|
| 46831.4 |
d. TRIMLITE Fiberglass Door |
6'8 "Non-Impact" Glazed Fiberglass Single Door - Inswing/Outswing (X – Configuration) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: N/A Other: See INST 46831.4 for Design Pressure Ratings, any additional use limitations, installation instructions and product particulars. Fasteners & connectors in areas within 3000 ft (914 m) of a saltwater coastline shall comply with FBC Sections 1711.1 or R332.1. |
Installation Instructions FL46831_R2_II_(d) Inst 46831.4.pdf Verified By: Lyndon F. Schmidt, P.E. 43409 Created by Independent Third Party: Yes Evaluation Reports FL46831_R2_AE_(d) Eval 46831.4.pdf Created by Independent Third Party: Yes |
|
|
| 46831.5 |
e. TRIMLITE Fiberglass Door |
6'8 "Non-Impact" Glazed Fiberglass Single Door with Sidelite(s) - Boxed Construction - Inswing/Outswing (OX or XO, OXO – Configurations) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: N/A Other: See INST 46831.5 for Design Pressure Ratings, any additional use limitations, installation instructions and product particulars. Fasteners & connectors in areas within 3000 ft (914 m) of a saltwater coastline shall comply with FBC Sections 1711.1 or R332.1. |
Installation Instructions FL46831_R2_II_(d) Inst 46831.5.pdf Verified By: Lyndon F. Schmidt, P.E. 43409 Created by Independent Third Party: Yes Evaluation Reports FL46831_R2_AE_(d) Eval 46831.5.pdf Created by Independent Third Party: Yes |
|
|
| 46831.6 |
f. TRIMLITE Fiberglass Door |
6'8 "Non-Impact" Glazed Fiberglass Double Door with and without Sidelites - Boxed Construction - Inswing/Outswing (XX, OXXO – Configurations) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: N/A Other: See INST 46831.6 for Design Pressure Ratings, any additional use limitations, installation instructions and product particulars. Fasteners & connectors in areas within 3000 ft (914 m) of a saltwater coastline shall comply with FBC Sections 1711.1 or R332.1. |
Installation Instructions FL46831_R2_II_(d) Inst 46831.6.pdf Verified By: Lyndon F. Schmidt, P.E. 43409 Created by Independent Third Party: Yes Evaluation Reports FL46831_R2_AE_(d) Eval 46831.6.pdf Created by Independent Third Party: Yes |