| 46817.1 |
SNAP-CLAD (.032" min.) |
.032" (min.) x 12" thru 18" Wide Aluminum Panel over Steel Deck |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-174.25 Other: |
Certification Agency Certificate FL46817_R1_C_CAC_25-0506.06 Snap-Clad 0.032in (min.) x 12in thru 18in Wide Aluminum Panel over Steel Deck.pdf Quality Assurance Contract Expiration Date 06/19/2030 Installation Instructions FL46817_R1_II_25-0506.06 Snap-Clad 0.032in (min.) x 12in thru 18in Wide Aluminum Panel over Steel Deck.pdf Verified By: Miami-Dade BCCO - CER Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 46817.2 |
SNAP-CLAD (.040" min.) |
.040" (min.) x 12" thru 18" Wide Aluminum Panel over Plywood Deck |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-174.25 Other: |
Certification Agency Certificate FL46817_R1_C_CAC_25-0506.08 Snap-Clad 0.040in (min.) x 12in thru 18in Wide Aluminum Panel over Wood Deck.pdf Quality Assurance Contract Expiration Date 06/19/2030 Installation Instructions FL46817_R1_II_25-0506.08 Snap-Clad 0.040in (min.) x 12in thru 18in Wide Aluminum Panel over Wood Deck.pdf Verified By: Miami-Dade BCCO - CER Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 46817.3 |
SNAP-CLAD (24 ga. min.) |
24 ga. (min.) x 12" thru 18" Wide Steel Panel over Steel Deck |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-181.75 Other: |
Certification Agency Certificate FL46817_R1_C_CAC_25-0506.07 Snap-Clad 24 ga. (min.) x 12in thru 18in Wide Steel Panel over Steel Deck.pdf Quality Assurance Contract Expiration Date 06/19/2030 Installation Instructions FL46817_R1_II_25-0506.07 Snap-Clad 24 ga. (min.) x 12in thru 18in Wide Steel Panel over Steel Deck.pdf Verified By: Miami-Dade BCCO - CER Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 46817.4 |
Tite-Loc Plus (.032" min.) |
.032" (min.) x 12" thru 18" Wide Aluminum Panel over Plywood Deck |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-174.25 Other: |
Certification Agency Certificate FL46817_R1_C_CAC_25-0506.04 Tite-Loc Plus 0.032in (min.) x 12in thru 18in Wide Aluminum Panel over Wood Deck.pdf Quality Assurance Contract Expiration Date 06/19/2030 Installation Instructions FL46817_R1_II_25-0506.04 Tite-Loc Plus 0.032in (min.) x 12in thru 18in Wide Aluminum Panel over Wood Deck.pdf Verified By: Miami-Dade BCCO - CER Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 46817.5 |
Tite-Loc Plus (.032" min.) |
.032" (min.) x 12" thru 18" Wide Aluminum Panel over Steel Deck |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-204.25 Other: |
Certification Agency Certificate FL46817_R1_C_CAC_25-0506.05 Tite-Loc Plus 0.032in (min.) x 12in thru 18in Wide Aluminum Panel over Steel Deck.pdf Quality Assurance Contract Expiration Date 06/19/2030 Installation Instructions FL46817_R1_II_25-0506.05 Tite-Loc Plus 0.032in (min.) x 12in thru 18in Wide Aluminum Panel over Steel Deck.pdf Verified By: Miami-Dade BCCO - CER Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 46817.6 |
Tite-Loc Plus (24 ga. min.) |
24 ga. (min.) x 12" thru 18" Wide Steel Panel over Steel Deck |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-196.75 Other: |
Certification Agency Certificate FL46817_R1_C_CAC_25-0506.02 Tite-Loc Plus 24 Gage (min.) x 12in thru 18in Wide Steel Panel over Steel Deck.pdf Quality Assurance Contract Expiration Date 06/19/2030 Installation Instructions FL46817_R1_II_25-0506.02 Tite-Loc Plus 24 Gage (min.) x 12in thru 18in Wide Steel Panel over Steel Deck.pdf Verified By: Miami-Dade BCCO - CER Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 46817.7 |
Tite-Loc Plus (24 ga. min.) |
24 ga. (min.) x 12" thru 18" Wide Steel Panel over Plywood Deck |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-204.25 Other: |
Certification Agency Certificate FL46817_R1_C_CAC_25-0506.03 Tite-Loc Plus 24 Gage (min.) x 12in thru 18in Wide Steel Panel over Wood Deck.pdf Quality Assurance Contract Expiration Date 06/19/2030 Installation Instructions FL46817_R1_II_25-0506.03 Tite-Loc Plus 24 Gage (min.) x 12in thru 18in Wide Steel Panel over Wood Deck.pdf Verified By: Miami-Dade BCCO - CER Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |