Florida Building Code Online
Florida Department of Business & Professional Regulation
myFlorida Logo Town Graphic
DBPR Home Button About DBPR Button DBPR Divisions Button Contact DBPR Button
Florida Department of Business & Professional Regulation
Office of the Secretary
Product Approval
USER: Public User
 
Product Approval Menu > Application Detail
 
FL # FL12483-R7
Application Type Revision
Code Version 2023
Application Status Approved
 
Comments
Archived
 
Product Manufacturer CertainTeed, LLC (Siding)
Address/Phone/Email 20 Moores Road
Malvern, PA 19355
(517) 780-3185
neil.j.sexton@saint-gobain.com
 
Authorized Signature Neil Sexton
neil.j.sexton@saint-gobain.com
 
Technical Representative Neil Sexton
Address/Phone/Email 803 Belden Road
Jackson, MI 49203
(517) 780-3185
neil.j.sexton@saint-gobain.com
 
Quality Assurance Representative Ken Berkowitz
Address/Phone/Email 750 E. Swedesford Road
Vallye Forge, PA 19482
ken.j.berkowitz@saint-gobain.com
 
Category Panel Walls
Subcategory Siding
 
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Evaluation Report - Hardcopy Received
 
Florida Engineer or Architect Name who developed the Evaluation Report Robert Nieminen
Florida License PE-59166
Quality Assurance Entity Intertek Testing Services NA, Inc. - QA Entity
Quality Assurance Contract Expiration Date 12/31/2026
Validated By John W. Knezevich, PE
  Validation Checklist - Hardcopy Received
 
Certificate of Independence FL12483_R7_COI_2023_07_COI_NIEMINEN.pdf
 
Referenced Standard and Year (of Standard)
StandardYear
ASTM D36792017
 
Equivalence of Product Standards
Certified By

 
Sections from the Code
 
 
 
Product Approval Method Method 1 Option D
 
Date Submitted 11/27/2023
Date Validated 11/30/2023
Date Pending FBC Approval 12/05/2023
Date Approved 02/13/2024
Date Revised 08/03/2026
 
Summary of Products
FL # Model, Number or Name Description
12483.1 CertainTeed Vinyl Siding Systems (NON-HVHZ) Vinyl Siding Systems for use in FBC non-HVHZ jurisdictions.
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-116
 Other: 1.) The DP noted in this application pertains to one particular siding system. Refer to PEER Appendix for all systems and design pressures. 2.) Refer to PEER Section 5 for Limits of Use.
Installation Instructions
 FL12483_R7_II_2023_11_27_FINAL_A1_PEER-CTS-001.A_FL12483-R7.pdf
 Verified By: Robert Nieminen PE-59166
 Created by Independent Third Party: Yes
Evaluation Reports
 FL12483_R7_AE_2023_11_27_FINAL_PEER-CTS-001.A_FL12483-R7.pdf
 Created by Independent Third Party: Yes
 
Back   Next
 
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
Product Approval Accepts:
Visa Mastercard Discover eCheck Amex