| 15125.1 |
Wood Impact Rated |
Glazed Outswing Doors |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +70/-70 Other: MAX. FRAME: 98.50" X 97.25" MAX. PANEL: 49" X 95.50" RATED FOR WATER INFILTRATION REQUIREMENTS AT THE DESIGN PRESSURE NOTED, SEE DRAWING ETO002 FOR FURTHER DETAILS & LIMITS OF USE |
Installation Instructions FL15125_R5_II_ETO002 SS 2019-06-19.pdf Verified By: Hermes F. Norero, P.E. Florida P.E. 73778 Created by Independent Third Party: Yes Evaluation Reports FL15125_R5_AE_PER6286 SS 2019-06-19.pdf Created by Independent Third Party: Yes |
|
|
| 15125.2 |
Wood Impact Rated |
Opaque Outswing Doors |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +60/-60 Other: MAX. FRAME: 98.50" X 97.25" MAX. PANEL: 49" X 95.50" RATED FOR WATER INFILTRATION REQUIREMENTS AT THE DESIGN PRESSURE NOTED, SEE DRAWING ETO003 FOR FURTHER DETAILS & LIMITS OF USE |
Installation Instructions FL15125_R5_II_ETO003 SS 2019-06-19.pdf Verified By: Hermes F. Norero, P.E. Florida P.E. 73778 Created by Independent Third Party: Yes Evaluation Reports FL15125_R5_AE_PER6287 SS 2019-06-19.pdf Created by Independent Third Party: Yes |
|
|
| 15125.3 |
Wood Impact Rated |
Glazed Inswing Doors |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +70/-70 Other: MAX. FRAME: 98.50" X 97.25" MAX. PANEL: 49" X 94.50" NOT RATED FOR WATER INFILTRATION REQUIREMENTS AT THE DESIGN PRESSURE NOTED ON ETO004, SINGLE DOOR UNIT DESIGN PRESSURE: +70/-70 PSF, DOUBLE DOOR UNIT DESIGN PRESSURE: +60/-60 PSF, SEE DRAWING ETO004 FOR FURTHER DETAILS & LIMITS OF USE |
Installation Instructions FL15125_R5_II_ETO004 SS 2019-06-19.pdf Verified By: Hermes F. Norero, P.E. Florida P.E. 73778 Created by Independent Third Party: Yes Evaluation Reports FL15125_R5_AE_PER6288 SS 2019-06-19.pdf Created by Independent Third Party: Yes |
|
|
| 15125.4 |
Wood Impact Rated |
Opaque Inswing Doors |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +70/-70 Other: MAX. FRAME: 98.50" X 97.25" MAX. PANEL: 49" X 94.50" NOT RATED FOR WATER INFILTRATION REQUIREMENTS AT THE DESIGN PRESSURE NOTED, SEE DRAWING ETO005 FOR FURTHER DETAILS & LIMITS OF USE |
Installation Instructions FL15125_R5_II_ETO005 SS 2019-06-19.pdf Verified By: Hermes F. Norero, P.E. Florida P.E. 73778 Created by Independent Third Party: Yes Evaluation Reports FL15125_R5_AE_PER6289 SS 2019-06-19.pdf Created by Independent Third Party: Yes |
|
|
| 15125.5 |
Wood Non-Impact Rated |
Glazed Outswing Doors |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +70/-70 Other: MAX. FRAME: 98.50" X 97.25" MAX. PANEL: 49" X 95.50" RATED FOR WATER INFILTRATION REQUIREMENTS AT THE DESIGN PRESSURE NOTED, SEE DRAWING ETO006 FOR FURTHER DETAILS & LIMITS OF USE |
Installation Instructions FL15125_R5_II_ETO006 SS 2019-06-19.pdf Verified By: Hermes F. Norero, P.E. Florida P.E. 73778 Created by Independent Third Party: Yes Evaluation Reports FL15125_R5_AE_PER6290 SS 2019-06-19.pdf Created by Independent Third Party: Yes |
|
|
| 15125.6 |
Wood Non-Impact Rated |
Glazed Inswing Doors |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +70/-70 Other: 98.50" X 97.25" MAX. PANEL: 49" X 94.50" NOT RATED FOR WATER INFILTRATION REQUIREMENTS AT THE DESIGN PRESSURE NOTED ON ETO007, SINGLE DOOR UNIT DESIGN PRESSURE: +70/-70 PSF, DOUBLE DOOR UNIT DESIGN PRESSURE: +60/-60 PSF, SEE DRAWING ETO007 FOR FOR FURTHER DETAILS & LIMITS OF USE |
Installation Instructions FL15125_R5_II_ETO007 SS 2019-06-19.pdf Verified By: Hermes F. Norero, P.E. Florida P.E. 73778 Created by Independent Third Party: Yes Evaluation Reports FL15125_R5_AE_PER6291 SS 2019-06-19.pdf Created by Independent Third Party: Yes |
|
|
| 15125.7 |
Wood Non-Impact Rated |
Opaque Outswing Doors |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +60/-60 Other: MAX. FRAME: 98.50" X 97.25" MAX. PANEL: 49" X 95.50" RATED FOR WATER INFILTRATION REQUIREMENTS AT THE DESIGN PRESSURE NOTED, SEE DRAWING ETO008 FOR FURTHER DETAILS & LIMITS OF USE |
Installation Instructions FL15125_R5_II_ETO008 SS 2019-06-19.pdf Verified By: Hermes F. Norero, P.E. Florida P.E. 73778 Created by Independent Third Party: Yes Evaluation Reports FL15125_R5_AE_PER6292 SS 2019-06-19.pdf Created by Independent Third Party: Yes |
|
|
| 15125.8 |
Wood Non-Impact Rated |
Opaque Inswing Doors |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +70/-70 Other: MAX. FRAME: 98.50" X 97.25" MAX. PANEL: 49" X 94.50" NOT RATED FOR WATER INFILTRATION REQUIREMENTS AT THE DESIGN PRESSURE NOTED, SEE DRAWING ETO009 FOR FURTHER DETAILS & LIMITS OF USE |
Installation Instructions FL15125_R5_II_ETO009 SS 2019-06-19.pdf Verified By: Hermes F. Norero, P.E. Florida P.E. 73778 Created by Independent Third Party: Yes Evaluation Reports FL15125_R5_AE_PER6293 SS 2019-06-19.pdf Created by Independent Third Party: Yes |