| 15162.1 |
UWDH 3644 |
Ultimate Wood Double Hung 3644, 407-H-1109 |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +40/-40 Other: Max. size: 41 3/8" x 97" (1051mm x 2464mm) Glass complies with ASTM E 1300. When products are installed in areas within 3,000 ft (914 m) of a saltwater coastline, fasteners shall comply with Section 1711.1.1 and connectors shall comply with Section 1711.1.2 as stated in FBC Edition 9, 2026. |
Certification Agency Certificate FL15162_R9_C_CAC_1109.14.15.pdf Quality Assurance Contract Expiration Date 08/06/2029 Installation Instructions FL15162_R9_II_78907.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 15162.2 |
UWDH 4036 |
Ultimate Wood Double Hung 4036, 407-H-1109 |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +40/-40 Other: Max. size: 45 3/8" x 81" (1153mm x 2057mm) Glass complies with ASTM E 1300. When products are installed in areas within 3,000 ft (914 m) of a saltwater coastline, fasteners shall comply with Section 1711.1.1 and connectors shall comply with Section 1711.1.2 as stated in FBC Edition 9, 2026. |
Certification Agency Certificate FL15162_R9_C_CAC_1109.11.13.pdf Quality Assurance Contract Expiration Date 08/06/2029 Installation Instructions FL15162_R9_II_78907.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 15162.3 |
UWDH RT 4036 |
Ultimate Wood Double Hung Round Top 407-H-739 |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +30/-30 Other: Max Frame Size 45 5/16" x 81" (1153mm x 2057mm), Glass complies with ASTM E1300. When products are installed in areas within 3,000 ft (914 m) of a saltwater coastline, fasteners shall comply with Section 1711.1.1 and connectors shall comply with Section 1711.1.2 as stated in FBC Edition 9, 2026. |
Certification Agency Certificate FL15162_R9_C_CAC_FL15162 CCL 739.45.46.47.48.pdf Quality Assurance Contract Expiration Date 04/27/2032 Installation Instructions FL15162_R9_II_INSTALL 68149.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 15162.4 |
UWDHP 6054 |
Ultimate Wood Double Hung Picture 1-5/8inch |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +40/-40 Other: Max Size: 1559 x 1448mm (61 3/8 x 57") Glass complies with ASTM E1300. When products are installed in areas within 3,000 ft (914 m) of a saltwater coastline, fasteners shall comply with Section 1711.1.1 and connectors shall comply with Section 1711.1.2 as stated in FBC Edition 9, 2026. |
Certification Agency Certificate FL15162_R9_C_CAC_739.43.pdf Quality Assurance Contract Expiration Date 07/20/2030 Installation Instructions FL15162_R9_II_126869.dwg.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 15162.5 |
UWDHP 6878 |
Ultimate Wood Double Hung Picture, 407-H-739 |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +40/-40 Other: Max size 1762mm x 2057mm (69 1/2" x 81") Glazing Material: The panels were glazed with nominal 25.4 mm (1") insulating glass fabricated from two 4.7mm (0.185") annealed sheets glass and an 16mm (0.63") stainless steel spacer. Glass complies with ASTM E1300. When products are installed in areas within 3,000 ft (914 m) of a saltwater coastline, fasteners shall comply with Section 1711.1.1 and connectors shall comply with Section 1711.1.2 as stated in FBC Edition 9, 2026. |
Certification Agency Certificate FL15162_R9_C_CAC_739.42.pdf Quality Assurance Contract Expiration Date 07/20/2030 Installation Instructions FL15162_R9_II_75122 126869.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 15162.6 |
UWDHP 6894 |
Ultimate Wood Double Hung Picture 6894, 407-H-1109 |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +40/-40 Other: 69 3/8" x 97" (1762mm x 2464mm) Glass complies with ASTM E 1300. When products are installed in areas within 3,000 ft (914 m) of a saltwater coastline, fasteners shall comply with Section 1711.1.1 and connectors shall comply with Section 1711.1.2 as stated in FBC Edition 9, 2026. |
Certification Agency Certificate FL15162_R9_C_CAC_1109.10.12.pdf Quality Assurance Contract Expiration Date 07/16/2029 Installation Instructions FL15162_R9_II_75122 126869.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 15162.7 |
UWDHT CN6820 |
Ultimate Wood Double Hung Transom CN6820 407-H-739 |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +40/-40 Other: Max Size: 1864 x 673mm (73 3/8 x 26 1/2") Glazing Material: The sash were glazed with nominal 17.8 mm (0.700") insulated glass comprised of two 3.1 mm (1/8") annealed lites separated by a 11.5mm stainless steel box spacer. Glass complies with ASTM E1300. When products are installed in areas within 3,000 ft (914 m) of a saltwater coastline, fasteners shall comply with Section 1711.1.1 and connectors shall comply with Section 1711.1.2 as stated in FBC Edition 9, 2026. |
Certification Agency Certificate FL15162_R9_C_CAC_739.44.pdf Quality Assurance Contract Expiration Date 07/20/2030 Installation Instructions FL15162_R9_II_75241 126868.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |