Florida Building Code Online
Florida Department of Business & Professional Regulation
myFlorida Logo Town Graphic
DBPR Home Button About DBPR Button DBPR Divisions Button Contact DBPR Button
Florida Department of Business & Professional Regulation
Office of the Secretary
Product Approval
USER: Public User
 
Product Approval Menu > Application Detail
 
FL # FL27152-R3
Application Type Revision
Code Version 2020
Application Status Approved
 
Comments
Archived
 
Product Manufacturer RESISTO, a division of Soprema, Inc.
Address/Phone/Email 1675 rue Haggarty
Drummondville, NON-US 00000
(819) 478-2400   Ext 3327
memathieu@soprema.ca
 
Authorized Signature Marc Mathieu
memathieu@soprema.ca
 
Technical Representative Marc Mathieu
Address/Phone/Email 1675 rue Haggarty
Drummondville, NON-US 00000
(819) 478-2400   Ext 3327
memathieu@soprema.ca
 
Quality Assurance Representative
Address/Phone/Email
 
Category Roofing
Subcategory Modified Bitumen Roof System
 
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Evaluation Report - Hardcopy Received
 
Florida Engineer or Architect Name who developed the Evaluation Report Robert Nieminen
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 12/21/2023
Validated By John W. Knezevich, PE
  Validation Checklist - Hardcopy Received
 
Certificate of Independence FL27152_R3_COI_2020_01_COI_NIEMINEN.pdf
 
Referenced Standard and Year (of Standard)
StandardYear
ASTM D19702015
ASTM D46012012
ASTM D61632015
ASTM D62222011
TAS 1142011
 
Equivalence of Product Standards
Certified By

 
Sections from the Code
 
 
 
Product Approval Method Method 1 Option D
 
Date Submitted 12/16/2020
Date Validated 12/17/2020
Date Pending FBC Approval 12/26/2020
Date Approved 02/09/2021
 
Summary of Products
FL # Model, Number or Name Description
27152.1 RESISTO Modified Bitumen Roof Systems Self-adhering, low-slope, modified bitumen roof systems
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: No
 Impact Resistant: N/A
 Design Pressure: +N/A/-127.5
 Other: 1.) The design pressure pertains to one assembly. Refer to ER Appendix for all assemblies and maximum allowable design pressures. 2.) Refer to ER Section 5 for Limits of Use.
Installation Instructions
 FL27152_R3_II_2020_12_16_FINAL_ER_RESISTO_MODBIT_HVHZ_FL27152-R3.pdf
 Verified By: Robert Nieminen PE-59166
 Created by Independent Third Party: Yes
Evaluation Reports
 FL27152_R3_AE_2020_12_16_FINAL_ER_RESISTO_MODBIT_HVHZ_FL27152-R3.pdf
 Created by Independent Third Party: Yes
 
Back   Next
 
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
Product Approval Accepts:
Visa Mastercard Discover eCheck Amex