| 6185.1 |
HPS-Sliding Glass Door-SMI |
Aluminum Sliding Glass Door |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: Door size, pressure, assembly and installation requirements are to be as specified in the attached drawing No. 1451. Job required design wind pressure shall be calculated in accordance with the FBC Chapter 16 and ASCE 7 Minimum Design Loads for Buildings and Other Structures. This door system is treated as a small missile impact product and must be shuttered when installed in code required large missile impact locations. All glass meets the requirements of the current ASTM E1300 standard. |
Installation Instructions FL6185_R8_II_Drawing 1451.pdf Verified By: Warren W. Schaefer, P.E. 44135 Created by Independent Third Party: Yes Evaluation Reports FL6185_R8_AE_Evaluation report WWS-280.pdf Created by Independent Third Party: Yes |
|
|
| 6185.2 |
HPS-Sliding Glass Door-SMI-1" IG |
Aluminum Sliding Glass Door |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: Door size, pressure, assembly and installation requirements are to be as specified in the attached drawing No. 1522. Job required design wind pressure shall be calculated in accordance with the FBC Chapter 16 and ASCE 7 Minimum Design Loads for Buildings and Other Structures. This door system is treated as a small missile impact product and must be shuttered when installed in code required large missile impact locations. All glass meets the requirements of the current ASTM E1300 standard. |
Installation Instructions FL6185_R8_II_Drawing 1522.pdf Verified By: Warren W. Schaefer, P.E. 44135 Created by Independent Third Party: Yes Evaluation Reports FL6185_R8_AE_Evaluation report WWS-283.pdf Created by Independent Third Party: Yes |
|
|
| 6185.3 |
HPX-Sliding Glass Door-LMI |
Aluminum Sliding Glass Door |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: Door size, pressure, assembly and installation requirements are to be as specified in the attached drawing No. 1692. Job required design wind pressure shall be calculated in accordance with the FBC Chapter 16 and ASCE 7 Minimum Design Loads for Buildings and Other Structures. This door system is rated as a large missile impact product for wind zone 4 & missile level āDā. All glass meets the requirements of the current ASTM E1300 standard. |
Installation Instructions FL6185_R8_II_Drawing 1692.pdf Verified By: Warren W. Schaefer, P.E. 44135 Created by Independent Third Party: Yes Evaluation Reports FL6185_R8_AE_Evaluation report WWS-282.pdf Created by Independent Third Party: Yes |
|
|
| 6185.4 |
HPX-Sliding Glass Door-SMI |
Aluminum Sliding Glass Door |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: Door size, pressure, assembly and installation requirements are to be as specified in the attached drawing No. 1469. Job required design wind pressure shall be calculated in accordance with the FBC Chapter 16 and ASCE 7 Minimum Design Loads for Buildings and Other Structures. This door system is treated as a small missile impact product and must be shuttered when installed in code required large missile impact locations. All glass meets the requirements of the current ASTM E1300 standard. |
Installation Instructions FL6185_R8_II_Drawing 1469.pdf Verified By: Warren W. Schaefer, P.E. 44135 Created by Independent Third Party: Yes Evaluation Reports FL6185_R8_AE_Evaluation report WWS-279.pdf Created by Independent Third Party: Yes |