Florida Building Code Online
Florida Department of Business & Professional Regulation
myFlorida Logo Town Graphic
DBPR Home Button About DBPR Button DBPR Divisions Button Contact DBPR Button
Florida Department of Business & Professional Regulation
Office of the Secretary
Product Approval
USER: Public User
 
Product Approval Menu > Application Detail
 
FL # FL47585
Application Type New
Code Version 2023
Application Status Approved
  *Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary.
 
Comments
Archived
 
Product Manufacturer Hy-lite specialty window
Address/Phone/Email 3000 E Johnson Ave
pensacola, FL 32514
(888) 256-2599   Ext 227
Charlie@hy-lite.com
 
Authorized Signature Halligan Charles
Charlie@hy-lite.com
 
Technical Representative charles halligan
Address/Phone/Email 3000 E Johnson Ave
pensacola, FL 32514
(888) 256-2599   Ext 227
charlie@hy-lite.com
 
Quality Assurance Representative charles halligan
Address/Phone/Email 3000 E Johnson Ave
pensacola, FL 32514
(888) 256-2599   Ext 227
charlie@hy-lite.com
 
Category Windows
Subcategory Fixed
 
Compliance Method Certification Mark or Listing
 
Certification Agency National Accreditation & Management Institute
Validated By National Accreditation & Management Institute
 
 
 
Referenced Standard and Year (of Standard)
StandardYear
AAMA/WDMA/CSA 101/I.S.2/A440-172017
AAMA/WDMA/CSA 101/I.S.2/A440-172011
 
Equivalence of Product Standards
Certified By

 
 
 
 
Product Approval Method Method 1 Option A
 
Date Submitted 07/03/2025
Date Validated 09/12/2025
Date Pending FBC Approval
Date Approved 09/16/2025
 
Summary of Products
FL # Model, Number or Name Description
47585.1 Deco IM J-Channel Frame with 1.0" Decorative Glass
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +50/-50
 Other: This product complies with ASTM E 1300-04
Certification Agency Certificate
 FL47585_R0_C_CAC_Deco IM.pdf
Quality Assurance Contract Expiration Date
 04/30/2029
Installation Instructions
 FL47585_R0_II_Dec IM Oval Inst FL.pdf
 Verified By: National Accreditation & Management Institute
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
47585.2 V1500-Deco Vinyl Fin Frame w/1.0" IG
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +100/-100
 Other: 50x50=100 PSF This product complies with ASTM E 1300-04
Certification Agency Certificate
 FL47585_R0_C_CAC_V1500-Deco.pdf
Quality Assurance Contract Expiration Date
 04/30/2029
Installation Instructions
 FL47585_R0_II_V1500 Deco installation instructions.pdf
 Verified By: National Accreditation & Management Institute
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
47585.3 V1500/V1580 - 6 Vinyl Fin Frame w 1.5 x 6 Acrylic Blocks
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: N/A
 Other: 74 x 74= 30 PSF 56 x 56=60 PSF
Certification Agency Certificate
 FL47585_R0_C_CAC_V1500-6 V1580-6 Gateway.pdf
 FL47585_R0_C_CAC_V1500-6 V1580-6 Stepdown.pdf
Quality Assurance Contract Expiration Date
 04/30/2029
Installation Instructions
 FL47585_R0_II_V1500 new construction installation FL.pdf
 Verified By: National Accreditation & Management Institute
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
47585.4 v1500/v1580-8 Vinyl Fin Frame w/ 1.5 x 8 Acrylic Block
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: N/A
 Other: 74 x 74=30 PSF 58 x 58=60 PSF
Certification Agency Certificate
 FL47585_R0_C_CAC_V1500-8 V1580-8 gateway.pdf
 FL47585_R0_C_CAC_V1500-8 V1580-8 Stepdown.pdf
Quality Assurance Contract Expiration Date
 04/30/2029
Installation Instructions
 FL47585_R0_II_V1500 new construction installation FL.pdf
 Verified By: National Accreditation & Management Institute
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
47585.5 v1500/v1580-9 Vinyl Fin Frame w/1.5 x 9 Acrylic Blocks
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: N/A
 Other: 74 x 74= 30 PSF 56 x 56=60 PSF
Certification Agency Certificate
 FL47585_R0_C_CAC_V1500-9 V1580-9 Gateway.pdf
 FL47585_R0_C_CAC_V1500-9 V1580-9 Stepdown.pdf
Quality Assurance Contract Expiration Date
 04/30/2029
Installation Instructions
 FL47585_R0_II_V1500 new construction installation FL.pdf
 Verified By: National Accreditation & Management Institute
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
47585.6 VF1500-6 Masonry or Retro-Fit vinyl Flange w/1.5 x 6 Acrylic blocks
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: N/A
 Other: 74 x 74=40 PSF 56 x 56=70 PSF
Certification Agency Certificate
 FL47585_R0_C_CAC_VF1500-6 Gateway.pdf
 FL47585_R0_C_CAC_VF1500-6 Stepdown.pdf
Quality Assurance Contract Expiration Date
 04/30/2029
Installation Instructions
 FL47585_R0_II_VF1500 installation instructions.pdf
 Verified By: Luis R. Lomas 62514
 Created by Independent Third Party: Yes
Evaluation Reports
 FL47585_R0_AE_VF1500 Validation 3RD party.pdf
 Created by Independent Third Party: Yes
47585.7 VF1500-8 Masonry or Retro-Fit vinyl Flange w/ 1.5 x 8 Acrylic blocks
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: N/A
 Other: 74 x 74=40 PSF 58 x 58=70PSF
Certification Agency Certificate
 FL47585_R0_C_CAC_VF1500-8 Gateway.pdf
 FL47585_R0_C_CAC_VF1500-8 Stepdown.pdf
Quality Assurance Contract Expiration Date
 04/30/2029
Installation Instructions
 FL47585_R0_II_VF1500 installation instructions.pdf
 Verified By: Luis R. Lomas 62514
 Created by Independent Third Party: Yes
Evaluation Reports
 FL47585_R0_AE_VF1500 Validation 3RD party.pdf
 Created by Independent Third Party: Yes
47585.8 VF1500-Deco Masonry or Retro-Fit vinyl Flange w/ 1.0" IG
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +100/-100
 Other:  
Certification Agency Certificate
 FL47585_R0_C_CAC_VF1500-Deco.pdf
Quality Assurance Contract Expiration Date
 04/30/2029
Installation Instructions
 FL47585_R0_II_VF1500 Deco Installation instructions.pdf
 Verified By: Luis R. Lomas 62514
 Created by Independent Third Party: Yes
Evaluation Reports
 Created by Independent Third Party: 
47585.9 VR3000-6 Vinyl Replacement w/ 1.5 x 6 Acrylic blocks
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: N/A
 Other: 74 x 74=40 PSF 56 x 56=70 PSF
Certification Agency Certificate
 FL47585_R0_C_CAC_VR3000-6 Gateway.pdf
 FL47585_R0_C_CAC_VR3000-6 Stepdown.pdf
Quality Assurance Contract Expiration Date
 04/30/2029
Installation Instructions
 FL47585_R0_II_FL185_R13_II_VR3000 Install 1 Hy-Lite.pdf
 Verified By: National Accreditation & Management Institute
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
47585.10 VR3000-8 Vinyl Replacement w/ 1.5 x 8 Acrylic Blocks
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: N/A
 Other: 74 x 74=40 PSF 58 x 58=70 PSF
Certification Agency Certificate
 FL47585_R0_C_CAC_VR3000-8 Gateway.pdf
 FL47585_R0_C_CAC_VR3000-8 Stepdown.pdf
Quality Assurance Contract Expiration Date
 04/30/2029
Installation Instructions
 FL47585_R0_II_FL185_R13_II_VR3000 Install 1 Hy-Lite.pdf
 Verified By: National Accreditation & Management Institute
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
 
Back   Next
 
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
Product Approval Accepts: