| 28127.1 |
1109 DH Picture IG 60"x84" (Single & Mulled Units) |
1109 DH Picture, Insulated Glass. 60"x84" Individual Unit Size. Qualifies Single & Mulled Units. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +55/-70 Other: Complies with ASTM E1300. Glass make-up consists of one lite of 1/4" annealed//8mm Endur spacer//Lami lite comprised of two lites of 4.7mm annealed with .090" PVB interlayer. |
Certification Agency Certificate FL28127_R4_C_CAC_449-H-037_17_19-20.pdf Quality Assurance Contract Expiration Date 11/04/2026 Installation Instructions FL28127_R4_II_1104-1105 DH Through Jamb.pdf FL28127_R4_II_1108-1109 Mulled DH Picture Installation Instructions Nail Fin--Thru Frame--Installation Clip.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 28127.2 |
Premium Coastal DH Operator (48"x84") Mulled to DH Picture (56"x84") Combination |
1104 Double-Hung (48"x84") Mulled to 1109 DH Picture (56"x84") Insulated Glass. Maximum Tributary Width = 52" based on mull testing & CCL 449-H-074.15 and .17. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +55/-70 Other: Complies with ASTM E1300. DH IG glass comprised of one lite of 5/32" annealed//8.0mm Endur Spacer//Lami lite comprised of two lites of 3/32" annealed with .090" PVB interlayer. Picture insulated glass make-up consists of one lite of 1/4" annealed//8mm Endur spacer//Lami lite comprised of two lites of 3/16" annealed with .090" PVB interlayer. |
Certification Agency Certificate FL28127_R4_C_CAC_448-H-074.19-.21.pdf FL28127_R4_C_CAC_449-H-074 15-17 Mullion CCL for DH 48x84 mulled to DH Picture 56x84.pdf Quality Assurance Contract Expiration Date 10/15/2025 Installation Instructions FL28127_R4_II_1104-1105 DH Through Jamb.pdf FL28127_R4_II_45-18772 DH Oper-Picture Comb.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 28127.3 |
Premium Coastal DH Operator/Picture Combination (Monolithic) |
1105 Double-Hung (48"x84") Mulled to 1108 DH Picture (56"x84") Insulated Glass. Maximum Tributary Width = 52" based on mull testing & CCL 449-H-074.15 and .17. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +55/-70 Other: Complies with ASTM E1300. DH Operator Monolithic 5/16" Laminated lite consists of two lites of 1/8" annealed with .090" PVB interlayer). DH Picture Monolithic 15/32" laminated lite consists of two lites of 4.7mm annealed or heat strengthened with .090" SGP interlayer. |
Certification Agency Certificate FL28127_R4_C_CAC_448-H-074.19-.21.pdf FL28127_R4_C_CAC_449-H-037_17_19-20.pdf FL28127_R4_C_CAC_449-H-074 15-17 Mullion CCL for DH 48x84 mulled to DH Picture 56x84.pdf Quality Assurance Contract Expiration Date 10/15/2025 Installation Instructions FL28127_R4_II_1104-1105 DH Through Jamb.pdf FL28127_R4_II_45-18772 DH Oper-Picture Comb.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 28127.4 |
Premium Coastal DH Picture |
1108 DH Picture. Single Glaze Monolithic 56"x96" Individual Units Only. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +55/-70 Other: Complies with ASTM E1300. Monolithic 15/32" Laminated lite consists of two lites of 4.7mm annealed or heat strengthened with .090" SGP interlayer. |
Certification Agency Certificate FL28127_R4_C_CAC_449-h-037 14-16 1108 DH Picture.pdf Quality Assurance Contract Expiration Date 03/29/2026 Installation Instructions FL28127_R4_II_1104-1105 DH Through Jamb.pdf FL28127_R4_II_1108 DH Picture SG Installation Instruction -- Nail Fin-Thru Frame-Installation Clip.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 28127.5 |
Premium Coastal DH Picture 1108 Mulled Units Monolithic Single Glaze) |
1108 DH Picture 56"x84" -- monolithic mulled units limited to maximum 56" width and 84" height per CCLs listed. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +55/-70 Other: Complies with ASTM E1300. Monolithic 15/32" laminated lite consists of two lites of 4.7mm annealed or heat strengthened with .090" SGP interlayer. |
Certification Agency Certificate FL28127_R4_C_CAC_449-H-037_14_16.pdf FL28127_R4_C_CAC_449-H-037_17_19-20.pdf Quality Assurance Contract Expiration Date 03/29/2026 Installation Instructions FL28127_R4_II_1104-1105 DH Through Jamb.pdf FL28127_R4_II_1108-1109 Mulled DH Picture Installation Instructions Nail Fin--Thru Frame--Installation Clip.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 28127.6 |
Premium Coastal DH Transom 48"x42" IG & SG |
1110/1111 DH Transom (48"x42") Insulated and Monolithic |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +55/-70 Other: Complies with ASTM E1300. Monolithic 11/32" Laminated lite consists of two lites of 1/8" annealed with .090" PVB interlayer. IG comprised of one lite of 3.9mm annealed//8.0mm Endur Spacer//Lami lite comprised of two lites of 2.3mm annealed with .090" PVB interlayer. |
Certification Agency Certificate FL28127_R4_C_CAC_449-H-037 05-07-08-10 Prem Coastal Transom IG - SG.pdf Quality Assurance Contract Expiration Date 07/28/2025 Installation Instructions FL28127_R4_II_1110-1111 Ind DH Transom Installation Instruction -- Nail Fin-Thru Jamb-Installation Clips 1.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 28127.7 |
Premium Coastal Double-Hung w/Transom IG & SG |
1105/1105 Double-Hung (48"x96") with 1110/1111 DH Transom (48"x42") Stacked Above |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +55/-70 Other: Complies with ASTM E1300. Monolithic 5/16" Laminated lite consists of two lites of 1/8" annealed with .090" PVB interlayer. IG glass comprised of one lite of 5/32" annealed//8.0mm Endur Spacer//Lami lite comprised of two lites of 3/32" annealed with .090" PVB interlayer. |
Certification Agency Certificate FL28127_R4_C_CAC_448-H-074.19-.21.pdf Quality Assurance Contract Expiration Date 05/23/2027 Installation Instructions FL28127_R4_II_1104-1105 DH Through Jamb.pdf FL28127_R4_II_1104-1105-1110-1111 DH Operator with DH Transom Stacked Above ESP024264P-2079.1.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |