Florida Building Code Online
Florida Department of Business & Professional Regulation
myFlorida Logo Town Graphic
DBPR Home Button About DBPR Button DBPR Divisions Button Contact DBPR Button
Florida Department of Business & Professional Regulation
Office of the Secretary
Product Approval
USER: Public User
 
Product Approval Menu > Application Detail
 
FL # FL14396-R9
Application Type Revision
Code Version 2026
Application Status Applied For
 
Comments
Archived
 
Product Manufacturer Clopay Building Products Company
Address/Phone/Email 8585 Duke Blvd.
Mason, OH 45040
(513) 770-4641
jwheeler@clopay.com
 
Authorized Signature Rebarchak Chris
crebarchak@clopay.com
 
Technical Representative
Address/Phone/Email
 
Quality Assurance Representative
Address/Phone/Email
 
Category Exterior Doors
Subcategory Roll-Up Exterior Door Assemblies
 
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Evaluation Report - Hardcopy Received
 
Florida Engineer or Architect Name who developed the Evaluation Report Shawn P. Kelley
Florida License PE-FL58299
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 03/01/2029
Validated By Eric C. VanHorn, P.E.
  Validation Checklist - Hardcopy Received
 
Certificate of Independence FL14396_R9_COI_S-S_Cert Ind_CLO_2015.pdf
 
Referenced Standard and Year (of Standard)
StandardYear
TAS 2011994
TAS 2021994
TAS 2031994
 
Equivalence of Product Standards
Certified By

Florida Licensed Professional Engineer or Architect
FL14396_R9_Equiv_20230712 - FBC - ASTM E330 equiv_s.pdf
FL14396_R9_Equiv_20230830 - FBC - ASCE 7 equiv.pdf
 
Sections from the Code
 
 
 
Product Approval Method Method 1 Option D
 
Date Submitted 10/14/2026
Date Validated
 
Summary of Products
FL # Model, Number or Name Description
14396.1 01. Insulated Door CP0001/CP0651 Slat
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +120 PSF/-120 PSF
 Other: Refer to DWG ES 16-137-CLO for maximum design pressure for each door width. The maximum height for all doors is 30 ft. Maximum design pressure is 120 psf. Impact resistant for 50 FPS missile impact speed. Mounting to steel jamb, concrete jamb, or filled CMU jamb. Slat material is available in galvanized or stainless steel.
Installation Instructions
 FL14396_R9_II_10-476 Installation Instructions, Service Door_S_S (8-20-26).pdf
 FL14396_R9_II_16-137 FL Approval - CP1, 50fps CLO_S_S (8-19-26).pdf
 Verified By: Shawn P. Kelley FL PE 58299
 Created by Independent Third Party: Yes
Evaluation Reports
 FL14396_R9_AE_FBC 2026 Code Compliance (CLO; 134-138, 140)_SandS (10-8-26).pdf
 Created by Independent Third Party: Yes
14396.2 02. Insulated Door CP0001/CP0651 Slat
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +120 PSF/-120 PSF
 Other: Refer to DWG ES 16-138-CLO for maximum design pressure for each door width. The maximum height for all doors is 30 ft. Maximum design pressure is 120 psf. Impact resistant for 80 FPS missile impact speed. Mounting to steel jamb, concrete jamb, or filled CMU jamb. Slat material is available in galvanized or stainless steel.
Installation Instructions
 FL14396_R9_II_10-476 Installation Instructions, Service Door_S_S (8-20-26).pdf
 FL14396_R9_II_16-138 FL Approval - CP1, 80fps CLO_S_S (8-19-26).pdf
 Verified By: Shawn P. Kelley FL PE 58299
 Created by Independent Third Party: Yes
Evaluation Reports
 FL14396_R9_AE_FBC 2026 Code Compliance (CLO; 134-138, 140)_SandS (10-8-26).pdf
 Created by Independent Third Party: Yes
14396.3 03. Insulated Door CP0001/CP0651 Slat
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +120 PSF/-120 PSF
 Other: Refer to DWG ES 16-140-CLO for maximum design pressure for each door width. The maximum height for all doors is 30 ft. Maximum design pressure is 120 psf. Mounting to steel jamb, concrete jamb, or filled CMU jamb. Slat material is available in galvanized or stainless steel.
Installation Instructions
 FL14396_R9_II_10-476 Installation Instructions, Service Door_S_S (8-20-26).pdf
 FL14396_R9_II_16-140 FL Approval - CP1, Non-Impact CLO_S_S (8-19-26).pdf
 Verified By: Shawn P. Kelley FL PE 58299
 Created by Independent Third Party: Yes
Evaluation Reports
 FL14396_R9_AE_FBC 2026 Code Compliance (CLO; 134-138, 140)_SandS (10-8-26).pdf
 Created by Independent Third Party: Yes
14396.4 04. Non-Insulated Door CP0020 slat
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +100 PSF/-100 PSF
 Other: Refer to DWG ES 16-134-CLO for maximum design pressure for each door width. The maximum height for all doors is 30 ft. Maximum design pressure is 100 psf. Impact resistant for 50 FPS missile impact speed. Mounting to steel jamb, concrete jamb, or filled CMU jamb. Slat material is available in galvanized or stainless steel.
Installation Instructions
 FL14396_R9_II_10-476 Installation Instructions, Service Door_S_S (8-20-26).pdf
 FL14396_R9_II_16-134 FL Approval - C20, 50fps CLO_SandS (12-15-25).pdf
 Verified By: Shawn P. Kelley FL PE 58299
 Created by Independent Third Party: Yes
Evaluation Reports
 FL14396_R9_AE_FBC 2026 Code Compliance (CLO; 134-138, 140)_SandS (10-8-26).pdf
 Created by Independent Third Party: Yes
14396.5 05. Non-Insulated Door CP0020 Slat
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +100 PSF/-100 PSF
 Other: Refer to DWG ES 16-135-CLO for maximum design pressure for each door width. The maximum height for all doors is 30 ft. Maximum design pressure is 100 psf. Impact resistant for 80 FPS missile impact speed. Mounting to steel jamb, concrete jamb, or filled CMU jamb. Slat material is available in galvanized or stainless steel.
Installation Instructions
 FL14396_R9_II_10-476 Installation Instructions, Service Door_S_S (8-20-26).pdf
 FL14396_R9_II_16-135 FL Approval - C20, 80fps CLO_SandS (12-15-25).pdf
 Verified By: Shawn P. Kelley FL PE 58299
 Created by Independent Third Party: Yes
Evaluation Reports
 FL14396_R9_AE_FBC 2026 Code Compliance (CLO; 134-138, 140)_SandS (10-8-26).pdf
 Created by Independent Third Party: Yes
14396.6 06. Non-Insulated Door CP0020 Slat
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +100 PSF/-100 PSF
 Other: Refer to DWG ES 16-136-CLO for maximum design pressure for each door width. The maximum height for all doors is 30 ft. Maximum design pressure is 100 psf. Mounting to steel jamb, concrete jamb, or filled CMU jamb. Slat material is available in galvanized or stainless steel.
Installation Instructions
 FL14396_R9_II_10-476 Installation Instructions, Service Door_S_S (8-20-26).pdf
 FL14396_R9_II_16-136 FL Approval - C20, Non-Impact CLO_SandS (12-12-25).pdf
 Verified By: Shawn P. Kelley FL PE 58299
 Created by Independent Third Party: Yes
Evaluation Reports
 FL14396_R9_AE_FBC 2026 Code Compliance (CLO; 134-138, 140)_SandS (10-8-26).pdf
 Created by Independent Third Party: Yes
14396.7 07. Non-Insulated Rolling Door - HVHZ CP0005 Slat
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +40 PSF/-40 PSF
 Other: Maximum 12'-5" Wide x 10'-0" Tall. Impact resistant for 50 FPS missile impact speed. Mounting to steel jamb, concrete jamb, or filled CMU jamb. Slat material available in galvanized or stainless steel.
Installation Instructions
 FL14396_R9_II_10-481 Installation Instructions, Counter Door_SandS (2-13-26).pdf
 FL14396_R9_II_16-132 FL Approval - CP5 CLO_SandS (2-11-26).pdf
 Verified By: Shawn Patrick Kelly FL 58299
 Created by Independent Third Party: No
Evaluation Reports
 FL14396_R9_AE_FBC 2026 Code Compliance (CLO; 132,133)_SandS (10-8-26).pdf
 Created by Independent Third Party: Yes
14396.8 08. Insulated Rolling Door - HVHZ Insulated CP0005 Slat
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +40 PSF/-40 PSF
 Other: Maximum 12'-5" Wide x 10'-0" Tall. Impact resistant for 50 FPS missile impact speed. Mounting to steel jamb, concrete jamb, or filled CMU jamb. Slat material available in galvanized or stainless steel.
Installation Instructions
 FL14396_R9_II_10-481 Installation Instructions, Counter Door_SandS (2-13-26).pdf
 FL14396_R9_II_16-133 FL Approval - INS CP5 CLO_SandS (2-13-26).pdf
 Verified By: Shawn Patrick Kelly PE 58299
 Created by Independent Third Party: No
Evaluation Reports
 FL14396_R9_AE_FBC 2026 Code Compliance (CLO; 132,133)_SandS (10-8-26).pdf
 Created by Independent Third Party: Yes
14396.9 09. Insulated Door CA1245 Slat
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +120 PSF/-120 PSF
 Other: Refer to DWG ES-16-141 for maximum design pressure for each door width. The maximum height for all doors is 30 ft. Maximum design pressure is 120psf. Impact resistant for 50 FPS missile impact speed. Mounting to steel jamb, concrete jamb, or filled CMU jamb. Slat material is available in galvanized or stainless steel.
Installation Instructions
 FL14396_R9_II_10-476 Installation Instructions, Service Door_S_S (8-20-26).pdf
 FL14396_R9_II_16-141 FL Approval - CP1 LOW U, 50fps CLO_S_S (8-19-26).pdf
 Verified By: Shawn Patrick Kelley PE 58299
 Created by Independent Third Party: No
Evaluation Reports
 FL14396_R9_AE_FBC 2026 Code Compliance (CLO; 141,142)_SandS (10-8-26).pdf
 Created by Independent Third Party: Yes
14396.10 10. Insulated Door CA1245 Slat
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +120 PSF/-120 PSF
 Other: Refer to DWG ES-16-142 for maximum design pressure for each door width. The maximum height for all doors is 30 ft. Maximum design pressure is 120psf. Mounting to steel jamb, concrete jamb, or filled CMU jamb. Slat material is available in galvanized or stainless steel.
Installation Instructions
 FL14396_R9_II_10-476 Installation Instructions, Service Door_S_S (8-20-26).pdf
 FL14396_R9_II_16-142 FL Approval - CP1 LOW U, Non-Impact CLO_S_S (8-19-26).pdf
 Verified By: Shawn Patrick Kelley PE 58299
 Created by Independent Third Party: No
Evaluation Reports
 FL14396_R9_AE_FBC 2026 Code Compliance (CLO; 141,142)_SandS (10-8-26).pdf
 Created by Independent Third Party: Yes
 
Back   Next
 
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
Product Approval Accepts:
Visa Mastercard Discover eCheck Amex