| 46026.1 |
01: 24ga Barrel Tile on 15/32" plywood |
24ga (min) Barrel Tile on 15/32" (min) plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-54 Other: See evaluation report |
Installation Instructions FL46026_R0_II_24ga_Tile_plywood-nonHVHZ_a.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL46026_R0_AE_24ga_Tile_plywood-nonHVHZ_a.pdf Created by Independent Third Party: Yes |
|
|
| 46026.2 |
02: 24ga Barrel Tile on 15/32" plywood |
24ga (min) Barrel Tile on 15/32" (min) plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-137 Other: See evaluation report |
Installation Instructions FL46026_R0_II_24ga_Tile_plywood-nonHVHZ_b.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL46026_R0_AE_24ga_Tile_plywood-nonHVHZ_b.pdf Created by Independent Third Party: Yes |
|
|
| 46026.3 |
03: 24ga Barrel Tile on 19/32" plywood |
24ga (min) Barrel Tile on 19/32" (min) plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-99 Other: See evaluation report |
Installation Instructions FL46026_R0_II_24ga_Tile_19-32_plywood-nonHVHZ_a.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL46026_R0_AE_24ga_Tile_19-32_plywood-nonHVHZ_a.pdf Created by Independent Third Party: Yes |
|
|
| 46026.4 |
04: 24ga Barrel Tile on 19/32" plywood |
24ga (min) Barrel Tile on 19/32" (min) plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-106 Other: See evaluation report |
Installation Instructions FL46026_R0_II_24ga_Tile_19-32_plywood-nonHVHZ_b.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL46026_R0_AE_24ga_Tile_19-32_plywood-nonHVHZ_b.pdf Created by Independent Third Party: Yes |
|
|
| 46026.5 |
05: 24ga Barrel Tile on 22ga Steel Deck |
24ga (min) Barrel Tile on 22ga (min) Steel B Deck |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-120 Other: See evaluation report |
Installation Instructions FL46026_R0_II_24ga_Tile_BDeck-nonHVHZ_a.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL46026_R0_AE_24ga_Tile_BDeck-nonHVHZ_a.pdf Created by Independent Third Party: Yes |
|
|
| 46026.6 |
06: 032 Aluminum Barrel Tile on 15/32" plywood |
Nominally 0.032" aluminum or thicker Barrel Tile on 15/32" (min) plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-92 Other: See evaluation report |
Installation Instructions FL46026_R0_II_032Al_Tile_plywood-nonHVHZ_a.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL46026_R0_AE_032Al_Tile_plywood-nonHVHZ_a.pdf Created by Independent Third Party: Yes |
|
|
| 46026.7 |
07: 032 Aluminum Barrel Tile on 15/32" plywood |
Nominally 0.032" aluminum or thicker Barrel Tile on 15/32" (min) plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-107 Other: See evaluation report |
Installation Instructions FL46026_R0_II_032Al_Tile_plywood-nonHVHZ_b.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL46026_R0_AE_032Al_Tile_plywood-nonHVHZ_b.pdf Created by Independent Third Party: Yes |