| 28500.1 |
26 Ga.5-V Roof Panel |
26 Ga. 5-V Roof Panel over 1x4 Wood Purlins over 7/16" OSB |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/-161.0psf Other: |
Installation Instructions FL28500_R3_II_26 Ga. 5-V Panel over 1x4 Wood Purlins.pdf Verified By: Johnathan E Green, P.E. 88223 Created by Independent Third Party: Yes Evaluation Reports FL28500_R3_AE_26 Ga. 5-V Panel over 1x4 Wood Purlins.pdf Created by Independent Third Party: Yes |
|
|
| 28500.2 |
Min. 26 Ga. PBR Roof Panel |
Min. 26 Ga. PBR Roof Panel over 15/32" Plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/-101.0psf Other: -63.5 psf @ 24" o.c. Fastener Pattern: 12"-12"-12". -101.0 psf @ 24" o.c. Fastener Pattern: 7"-5"-7"-5"-7" . Install per manufacturer's details. Not for use in HVHZ Zones. |
Installation Instructions FL28500_R3_II_26 Ga. PBR Panel over Plywood.pdf Verified By: Johnathan E Green, P.E. 88223 Created by Independent Third Party: Yes Evaluation Reports FL28500_R3_AE_26 Ga. PBR Panel over Plywood.pdf Created by Independent Third Party: Yes |
|
|
| 28500.3 |
Min. 26 Ga. PBR Roof Panel |
Min. 26 Ga. PBR Roof Panel over 1x4 Wood Purlins over 15/32" Plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/-108.5psf Other: -63.5 psf @ 24" o.c. Fastener Pattern: 12"-12"-12". -108.5 psf @ 24" o.c. Fastener Pattern: 7"-5"-7"-5"-7". Install per manufacturer's details. Not for use in HVHZ Zones. |
Installation Instructions FL28500_R3_II_26 Ga. PBR Panel over 1x4 Wood Purlins.pdf Verified By: Johnathan E Green, P.E. 88223 Created by Independent Third Party: Yes Evaluation Reports FL28500_R3_AE_26 Ga. PBR Panel over 1x4 Wood Purlins.pdf Created by Independent Third Party: Yes |
|
|
| 28500.4 |
Min. 29 Ga. Tuff Rib Roof Panel |
Min. 29 Ga. Tuff Rib Roof Panel over 15/32" Plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/-101.0psf Other: -78.5 psf @ 24" o.c. Fastener Pattern: 9"-9"-9"-9". -101.0 psf @ 24" o.c. Fastener Pattern: 6"-3"-6"-3"-6"-3"-6".Install per manufacturer's details. Not for use in HVHZ Zones. |
Installation Instructions FL28500_R3_II_29 Ga. Tuff Rib over Plywood.pdf Verified By: Johnathan E Green, P.E. 88223 Created by Independent Third Party: Yes Evaluation Reports FL28500_R3_AE_29 Ga. Tuff Rib over Plywood.pdf Created by Independent Third Party: Yes |
|
|
| 28500.5 |
Min. 29 Ga. Tuff Rib Roof Panel |
Min. 29 Ga. Tuff Rib Roof Panel over 1x4 Wood Purlins over 15/32" Plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/-101.0psf Other: -78.5 psf @ 24" o.c. Fastener Pattern: 9"-9"-9'-9". -101.0 psf @ 24" o.c. 6"-3"-6"-3"-6"-3"-6". Manufacturer's details. Not for use in HVHZ Zones. |
Installation Instructions FL28500_R3_II_29 Ga. Tuff Rib Panel over 1x4 Wood Purlins.pdf Verified By: Johnathan E Green, P.E. 88223 Created by Independent Third Party: Yes Evaluation Reports FL28500_R3_AE_29 Ga. Tuff Rib Panel over 1x4 Wood Purlins.pdf Created by Independent Third Party: Yes |