Florida Building Code Online
Florida Department of Business & Professional Regulation
myFlorida Logo Town Graphic
DBPR Home Button About DBPR Button DBPR Divisions Button Contact DBPR Button
Florida Department of Business & Professional Regulation
Office of the Secretary
Product Approval
USER: Public User
 
Product Approval Menu > Application Detail
 
FL # FL28500-R2
Application Type Revision
Code Version 2023
Application Status Approved
 
Comments
Archived
 
Product Manufacturer Century Metal, LLC.
Address/Phone/Email 25284 Highway 17 North
Waverly, GA 31565
(912) 576-2840
jeff@wvmetal.com
 
Authorized Signature Jeff McMillion
jeff@wvmetal.com
 
Technical Representative
Address/Phone/Email
 
Quality Assurance Representative
Address/Phone/Email
 
Category Roofing
Subcategory Metal Roofing
 
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Evaluation Report - Hardcopy Received
 
Florida Engineer or Architect Name who developed the Evaluation Report Johnathan E. Green, P.E.
Florida License PE-88223
Quality Assurance Entity Keystone Certifications, Inc.
Quality Assurance Contract Expiration Date 05/01/2035
Validated By Steven M. Urich, PE
  Validation Checklist - Hardcopy Received
 
Certificate of Independence FL28500_R2_COI_Letter of Certification.pdf
 
Referenced Standard and Year (of Standard)
StandardYear
FM 44711992
UL 18972015
UL 5802006
 
Equivalence of Product Standards
Certified By

 
Sections from the Code
 
 
 
Product Approval Method Method 1 Option D
 
Date Submitted 04/20/2024
Date Validated 04/23/2024
Date Pending FBC Approval 04/25/2024
Date Approved 06/18/2024
Date Revised 09/20/2026
 
Summary of Products
FL # Model, Number or Name Description
28500.1 26 Ga.5-V Roof Panel 26 Ga. 5-V Roof Panel over 1x4 Wood Purlins over 7/16" OSB
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +N/A/-161.0psf
 Other:  
Installation Instructions
 FL28500_R2_II_26 Ga. 5-V Panel over 1x4 Wood Purlins.pdf
 Verified By: Johnathan E Green, P.E. 88223
 Created by Independent Third Party: Yes
Evaluation Reports
 FL28500_R2_AE_26 Ga. 5-V Panel over 1x4 Wood Purlins.pdf
 Created by Independent Third Party: Yes
28500.2 Min. 26 Ga. PBR Roof Panel Min. 26 Ga. PBR Roof Panel over 15/32" Plywood
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +N/A/-101.0psf
 Other: -63.5 psf @ 24" o.c. Fastener Pattern: 12"-12"-12". -101.0 psf @ 24" o.c. Fastener Pattern: 7"-5"-7"-5"-7" . Install per manufacturer's details. Not for use in HVHZ Zones.
Installation Instructions
 FL28500_R2_II_26 Ga. PBR Panel over Plywood.pdf
 Verified By: Johnathan E Green, P.E. 88223
 Created by Independent Third Party: Yes
Evaluation Reports
 FL28500_R2_AE_26 Ga. PBR Panel over Plywood.pdf
 Created by Independent Third Party: Yes
28500.3 Min. 26 Ga. PBR Roof Panel Min. 26 Ga. PBR Roof Panel over 1x4 Wood Purlins over 15/32" Plywood
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +N/A/-108.5psf
 Other: -63.5 psf @ 24" o.c. Fastener Pattern: 12"-12"-12". -108.5 psf @ 24" o.c. Fastener Pattern: 7"-5"-7"-5"-7". Install per manufacturer's details. Not for use in HVHZ Zones.
Installation Instructions
 FL28500_R2_II_26 Ga. PBR Panel over 1x4 Wood Purlins.pdf
 Verified By: Johnathan E Green, P.E. 88223
 Created by Independent Third Party: Yes
Evaluation Reports
 FL28500_R2_AE_26 Ga. PBR Panel over 1x4 Wood Purlins.pdf
 Created by Independent Third Party: Yes
28500.4 Min. 29 Ga. Tuff Rib Roof Panel Min. 29 Ga. Tuff Rib Roof Panel over 15/32" Plywood
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +N/A/-101.0psf
 Other: -78.5 psf @ 24" o.c. Fastener Pattern: 9"-9"-9"-9". -101.0 psf @ 24" o.c. Fastener Pattern: 6"-3"-6"-3"-6"-3"-6".Install per manufacturer's details. Not for use in HVHZ Zones.
Installation Instructions
 FL28500_R2_II_29 Ga. Tuff Rib over Plywood.pdf
 Verified By: Johnathan E Green, P.E. 88223
 Created by Independent Third Party: Yes
Evaluation Reports
 FL28500_R2_AE_29 Ga. Tuff Rib over Plywood.pdf
 Created by Independent Third Party: Yes
28500.5 Min. 29 Ga. Tuff Rib Roof Panel Min. 29 Ga. Tuff Rib Roof Panel over 1x4 Wood Purlins over 15/32" Plywood
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +N/A/-101.0psf
 Other: -78.5 psf @ 24" o.c. Fastener Pattern: 9"-9"-9'-9". -101.0 psf @ 24" o.c. 6"-3"-6"-3"-6"-3"-6". Manufacturer's details. Not for use in HVHZ Zones.
Installation Instructions
 FL28500_R2_II_29 Ga. Tuff Rib Panel over 1x4 Wood Purlins.pdf
 Verified By: Johnathan E Green, P.E. 88223
 Created by Independent Third Party: Yes
Evaluation Reports
 FL28500_R2_AE_29 Ga. Tuff Rib Panel over 1x4 Wood Purlins.pdf
 Created by Independent Third Party: Yes
 
Back   Next
 