| 48095.1 |
Fiberglass Side-Hinged Door w/ Multipoint Hardware |
6'-8" Impact Glazed I/S or O/S Single or Double Door w/ or w/o Sidelites |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +50/-50 Other: 12'-0" x 6'-8" max nominal size. See DWG-PL-FL0185 for details. |
Certification Agency Certificate FL48095_R0_C_CAC_NI016872.02.pdf Quality Assurance Contract Expiration Date 01/31/2030 Installation Instructions FL48095_R0_II_DWG-PL-FL0185-25.pdf Verified By: Lucas A. Turner PE #58201 Created by Independent Third Party: Yes Evaluation Reports FL48095_R0_AE_EvalReport-PL-FL0185-25.pdf Created by Independent Third Party: Yes |
|
|
| 48095.2 |
Fiberglass Side-Hinged Door w/ Multipoint Hardware |
8'-0" Impact Glazed I/S Single or Double Door w/ or w/o Sidelites |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +40/-45 Other: 12'-0" x 8'-0" max nominal size. See DWG-PL-FL0186 for details. |
Certification Agency Certificate FL48095_R0_C_CAC_NI016872.01.pdf Quality Assurance Contract Expiration Date 01/31/2030 Installation Instructions FL48095_R0_II_DWG-PL-FL0186-25.pdf Verified By: Lucas A. Turner PE #58201 Created by Independent Third Party: Yes Evaluation Reports FL48095_R0_AE_EvalReport-PL-FL0186-25.pdf Created by Independent Third Party: Yes |
|
|
| 48095.3 |
Fiberglass Side-Hinged Door w/ Multipoint Hardware |
8'-0" Impact Glazed O/S Single or Double Door w/ or w/o Sidelites |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +45/-45 Other: 12'-0" x 8'-0" max nominal size. See DWG-PL-FL0186 for details. |
Certification Agency Certificate FL48095_R0_C_CAC_NI016872.01.pdf Quality Assurance Contract Expiration Date 01/31/2030 Installation Instructions FL48095_R0_II_DWG-PL-FL0186-25.pdf Verified By: Lucas A. Turner PE #58201 Created by Independent Third Party: Yes Evaluation Reports FL48095_R0_AE_EvalReport-PL-FL0186-25.pdf Created by Independent Third Party: Yes |
|
|
| 48095.4 |
Fiberglass Side-Hinged Door w/ Multipoint Hardware |
6'-8" Opaque I/S or O/S Single or Double Door w/ or w/o Sidelites |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +50/-50 Other: 12'-0" x 6'-8" max nominal size. See DWG-PL-FL0265 for details. |
Certification Agency Certificate FL48095_R0_C_CAC_NI016872.06.pdf Quality Assurance Contract Expiration Date 01/31/2030 Installation Instructions FL48095_R0_II_DWG-PL-FL0265-25.pdf Verified By: Lucas A. Turner PE #58201 Created by Independent Third Party: Yes Evaluation Reports FL48095_R0_AE_EvalReport-PL-FL0265-25.pdf Created by Independent Third Party: Yes |
|
|
| 48095.5 |
Fiberglass Side-Hinged Door w/ Multipoint Hardware |
8'-0" Opaque I/S Single or Double Door w/ or w/o Sidelites |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +40/-45 Other: 12'-0" x 8'-0" max nominal size. See DWG-PL-FL0266 for details. |
Certification Agency Certificate FL48095_R0_C_CAC_NI016872.07.pdf Quality Assurance Contract Expiration Date 01/31/2030 Installation Instructions FL48095_R0_II_DWG-PL-FL0266-25.pdf Verified By: Lucas A. Turner PE #58201 Created by Independent Third Party: Yes Evaluation Reports FL48095_R0_AE_EvalReport-PL-FL0266-25.pdf Created by Independent Third Party: Yes |
|
|
| 48095.6 |
Fiberglass Side-Hinged Door w/ Multipoint Hardware |
8'-0" Opaque O/S Single or Double Door w/ or w/o Sidelites |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +45/-45 Other: 12'-0" x 8'-0" max nominal size. See DWG-PL-FL0266 for details. |
Certification Agency Certificate FL48095_R0_C_CAC_NI016872.07.pdf Quality Assurance Contract Expiration Date 01/31/2030 Installation Instructions FL48095_R0_II_DWG-PL-FL0266-25.pdf Verified By: Lucas A. Turner PE #58201 Created by Independent Third Party: Yes Evaluation Reports FL48095_R0_AE_EvalReport-PL-FL0266-25.pdf Created by Independent Third Party: Yes |