Florida Building Code Online
Florida Department of Business & Professional Regulation
myFlorida Logo Town Graphic
DBPR Home Button About DBPR Button DBPR Divisions Button Contact DBPR Button
Florida Department of Business & Professional Regulation
Office of the Secretary
Product Approval
USER: Public User
 
Product Approval Menu > Application Detail
 
FL # FL37158-R2
Application Type Revision
Code Version 2026
Application Status Approved
 
Comments
Archived
 
Product Manufacturer Berridge Manufacturing Co.
Address/Phone/Email 1720 Maury
Houston, TX 77026
(210) 650-7057
Lreimert@berridge.com
 
Authorized Signature James Buckner
jimmy@cbuckinc.net
 
Technical Representative Lisa Reimert
Address/Phone/Email 6515 Fratt Rd.
San Antonio, TX 78218
(210) 650-2507
lreimert@berridge.com
 
Quality Assurance Representative
Address/Phone/Email
 
Category Roofing
Subcategory Metal Roofing
 
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Evaluation Report - Hardcopy Received
 
Florida Engineer or Architect Name who developed the Evaluation Report James L. Buckner, P.E. @ CBUCK, Inc
Florida License PE-31242
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 12/31/2027
Validated By Steven M. Urich, PE
  Validation Checklist - Hardcopy Received
 
Certificate of Independence FL37158_R2_COI_CertOfIndep_2026.pdf
 
Referenced Standard and Year (of Standard)
StandardYear
TAS 1252003
 
Equivalence of Product Standards
Certified By

 
Sections from the Code
 
 
 
Product Approval Method Method 1 Option D
 
Date Submitted 08/20/2026
Date Validated 08/20/2026
Date Pending FBC Approval 08/27/2026
Date Approved 10/13/2026
 
Summary of Products
FL # Model, Number or Name Description
37158.1 “Zee-Lock Panel or Curved Zee-Lock Panel with Optional Batten Cap” “Zee-Lock” or “Curved Zee-Lock” with Optional Batten Cap Standing Seam Roof Panel, 2” Rib Height, 16” wide, 24 or 22 gauge Steel roof panel restrained by panel clips, fastened through optional rigid insulation into Steel Deck
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +N/A/-Table A
 Other: Refer to Certification and Evaluation Report for Conditions & Limitations of Use. Refer to manufacturer's installation instructions as a supplemental guide.
Installation Instructions
 FL37158_R2_II_1_ZeeLock_BattenCap_Stl_SteelDeck__EVALREPORT.pdf
 Verified By: James L. Buckner, P.E. P.E. #31242
 Created by Independent Third Party: Yes
Evaluation Reports
 FL37158_R2_AE_1_ZeeLock_BattenCap_Stl_SteelDeck__EVALREPORT.pdf
 Created by Independent Third Party: Yes
 