| 37138.1 |
TremLock "R" Panel |
Through-fastened metal roof panel over open framing. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +0/-52.5 Other: Refer to posted UL Constructions for attachment requirements. Minimum roof slope shall be the greater of 2:12 (17-percent slope) or the limitations set forth in FBC 1507.4.2. Coil sheet used to fabricate the metal panels shall comply with FBC 1507.4.3. Fasteners shall be as specified in the UL Constructions, limited per FBC 1507.4.4. Diaphragm load is outside the scope of this Method 1A submittal. |
Certification Agency Certificate FL37138_R3_C_CAC_TGKX.161.pdf FL37138_R3_C_CAC_TGKX.167.pdf Quality Assurance Contract Expiration Date 04/07/2028 Installation Instructions FL37138_R3_II_TGKX.161.pdf FL37138_R3_II_TGKX.167.pdf Verified By: UL LLC Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 37138.2 |
TremLock T-238 |
T-panel, standing seam metal roof over open framing |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +0/-52.5 Other: Refer to posted UL Constructions for attachment requirements. Minimum roof slope shall be the greater of 2:12 (17-percent slope) or the limitations set forth in FBC 1507.4.2. Coil sheet used to fabricate the metal panels shall comply with FBC 1507.4.3. Fasteners shall be as specified in the UL Constructions, limited per FBC 1507.4.4. Diaphragm load is outside the scope of this Method 1A submittal. |
Certification Agency Certificate FL37138_R3_C_CAC_TGKX.268.pdf Quality Assurance Contract Expiration Date 04/07/2028 Installation Instructions FL37138_R3_II_TGKX.268.pdf Verified By: UL LLC Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 37138.3 |
TremLock VP1.5 |
Vertical-leg, standing seam metal roof over open framing. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +0/-52.5 Other: Refer to posted UL Constructions for attachment requirements. Minimum roof slope shall be the greater of 2:12 (17-percent slope) or the limitations set forth in FBC 1507.4.2. Coil sheet used to fabricate the metal panels shall comply with FBC 1507.4.3. Fasteners shall be as specified in the UL Constructions, limited per FBC 1507.4.4. Diaphragm load is outside the scope of this Method 1A submittal. |
Certification Agency Certificate FL37138_R3_C_CAC_TGKX.506C.pdf Quality Assurance Contract Expiration Date 04/07/2028 Installation Instructions FL37138_R3_II_TGKX.506C.pdf Verified By: UL LLC Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 37138.4 |
TremLock VP212, VP216, VP218 and VP180 |
Vertical-leg, mechanically-seamed, standing seam metal roof over open framing |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +0/-52.5 Other: Refer to posted UL Constructions for attachment requirements. Minimum roof slope shall be the greater of 2:12 (17-percent slope) or the limitations set forth in FBC 1507.4.2. Coil sheet used to fabricate the metal panels shall comply with FBC 1507.4.3. Fasteners shall be as specified in the UL Constructions, limited per FBC 1507.4.4. Diaphragm load is outside the scope of this Method 1A submittal. |
Certification Agency Certificate FL37138_R3_C_CAC_TGKX.506.pdf Quality Assurance Contract Expiration Date 04/07/2028 Installation Instructions FL37138_R3_II_TGKX.506.pdf Verified By: UL LLC Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |