Florida Building Code Online
Florida Department of Business & Professional Regulation
myFlorida Logo Town Graphic
DBPR Home Button About DBPR Button DBPR Divisions Button Contact DBPR Button
Florida Department of Business & Professional Regulation
Office of the Secretary
Product Approval
USER: Public User
 
Product Approval Menu > Application Detail
 
FL # FL3774-R9
Application Type Affirmation
Code Version 2023
Application Status Approved
  *Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary.
 
Comments
Archived
 
Product Manufacturer Dean Steel Buildings, Inc
Address/Phone/Email 2929 Industrial Avenue
Fort Myers, FL 33901
(239) 334-1051
nandean@deansteelbuildings.com
 
Authorized Signature Nanette Dean
nandean@deansteelbuildings.com
 
Technical Representative Nanette Dean
Address/Phone/Email 2929 Industrial Avenue
Fort Myers, FL 33901
nandean@deansteelbuildings.com
 
Quality Assurance Representative Nanette Dean
Address/Phone/Email 2929 Industrial Avenue
Fort Myers, FL 33901
(239) 334-1051
nandean@deansteelbuildings.com
 
Category Structural Components
Subcategory Roof Deck
 
Compliance Method Certification Mark or Listing
 
Certification Agency UL LLC
Validated By UL LLC
 
 
 
Referenced Standard and Year (of Standard)
StandardYear
UL5802006
 
Equivalence of Product Standards
Certified By

 
 
 
Documentation from approved Evaluation or Validation Entity
 
 
Product Approval Method Method 1 Option A
 
Date Submitted 12/18/2023
Date Validated 12/18/2023
Date Pending FBC Approval
Date Approved 12/30/2023
 
Summary of Products
FL # Model, Number or Name Description
3774.1 Rib-12 Screw down roof panel
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +52.5/-52.5
 Other: The structural panel is to be installed over steel framing in accordance with the load tables and UL Construction 65. Minimum recommended slope 0.5/12. Not to be used in HVHZ. Design engineer must evaluate the panel web crippling and fastener pullout/pullover per AISI specifications. Design pressure is given for 26 ga, 60" o.c.
Certification Agency Certificate
 FL3774_R9_C_CAC_TJPV.R7706 Card.pdf
 FL3774_R9_C_CAC_UL.pdf
Quality Assurance Contract Expiration Date
 02/05/2028
Installation Instructions
 FL3774_R9_II_TGKX.65.pdf
 Verified By: Nanette Dean FL45851
 Created by Independent Third Party: No
Evaluation Reports
 Created by Independent Third Party: 
3774.2 Rib-6 Screw down roof panel
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +52.5/-52.5
 Other: The structural panel is to be installed over steel framing in accordance with the load tables and UL Construction 39. Minimum recommended slope 0.5/12. Not to be used in HVHZ. Design engineer must evaluate the panel web crippling and fastener pullout/pullover per AISI specifications. Design pressure is given for 26 ga, 60" o.c.
Certification Agency Certificate
 FL3774_R9_C_CAC_TJPV.R7706 Card.pdf
 FL3774_R9_C_CAC_UL.pdf
Quality Assurance Contract Expiration Date
 02/05/2028
Installation Instructions
 FL3774_R9_II_TGKX-39.pdf
 Verified By: Nanette Dean FL45851
 Created by Independent Third Party: No
Evaluation Reports
 Created by Independent Third Party: 
 
Back   Next
 
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
Product Approval Accepts:
Visa Mastercard Discover eCheck Amex