| 3775.1 |
Rib-12 |
Screw down wall panel |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +52.5/-52.5 Other: The structural panel is to be installed over steel framing in accordance with the load tables and UL Construction 65. Not to be used in HVHZ. Design engineer must evaluate the panel web crippling and fastener pullout/pullover per AISI specifications. Design pressure is given for 26 ga, 60" o.c. |
Certification Agency Certificate FL3775_R8_C_CAC_TJPV.R7706 Card.pdf FL3775_R8_C_CAC_UL.pdf Quality Assurance Contract Expiration Date 12/15/2018 Installation Instructions FL3775_R8_II_TGKX.65.pdf Verified By: Nanette Dean FL45851 Created by Independent Third Party: No Evaluation Reports Created by Independent Third Party: |
|
|
| 3775.2 |
Rib-6 |
Screw down wall panel |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +52.5/-52.5 Other: The structural panel is to be installed over steel framing in accordance with the load tables and UL Construction 39. Not to be used in HVHZ. Design engineer must evaluate the panel web crippling and fastener pullout/pullover per AISI specifications. Design pressure is given for 26 ga, 60" o.c. |
Certification Agency Certificate FL3775_R8_C_CAC_TJPV.R7706 Card.pdf FL3775_R8_C_CAC_UL.pdf Quality Assurance Contract Expiration Date 12/15/2018 Installation Instructions FL3775_R8_II_TGKX-39.pdf Verified By: Nanette Dean FL45851 Created by Independent Third Party: No Evaluation Reports Created by Independent Third Party: |