| 47958.1 |
001 W4-09 DSIU-1A171: 9130, 9131, 9133, HDP13, HDPF13, HDPL13, 7130, 7131, 7133, 8130, 8131, 8133 |
Double-skin Insulated PUR (exterior skin 27 ga. min.; interior skin 27 ga. min.) Single-Car (up to 9’0” wide) WINDCODE® W4 Garage Door |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +25 PSF/-28 PSF Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.2 FBC). |
Installation Instructions FL47958_R0_II_104947-Rev02.pdf Verified By: James D. Wheeler FL PE 91932 Created by Independent Third Party: No Evaluation Reports FL47958_R0_AE_CCER_251214-B-00.pdf Created by Independent Third Party: No |
|
|
| 47958.2 |
002 W4-16 DSIU-1A171: 9130, 9131, 9133, HDP13, HDPF13, HDPL13, 7130, 7131, 7133, 8130, 8131, 8133 |
Double-skin Insulated PUR (exterior skin 27 ga. min.; interior skin 27 ga. min.) Double-Car (9’2” to 16’0” wide) WINDCODE® W4 Garage Door |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +24 PSF/-26.5 PSF Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.2 FBC). |
Installation Instructions FL47958_R0_II_104704-Rev02.pdf Verified By: James D. Wheeler FL PE 91932 Created by Independent Third Party: No Evaluation Reports FL47958_R0_AE_CCER_251214-B-00.pdf Created by Independent Third Party: No |
|
|
| 47958.3 |
003 W4-18 DSIU-1A171: 9130, 9131, 9133, HDP13, HDPF13, HDPL13, 7130, 7131, 7133, 8130, 8131, 8133 |
Double-skin Insulated PUR (exterior skin 27 ga. min.; interior skin 27 ga. min.) 16'2" to 18'0" wide WINDCODE® W4 Garage Door |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +24 PSF/-26 PSF Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.2 FBC). |
Installation Instructions FL47958_R0_II_104887-Rev02.pdf Verified By: James D. Wheeler FL PE 91932 Created by Independent Third Party: No Evaluation Reports FL47958_R0_AE_CCER_251214-B-00.pdf Created by Independent Third Party: No |
|
|
| 47958.4 |
004 W5-09 DSIU-1A171: 9130, 9131, 9133, HDP13, HDPF13, HDPL13, 7130, 7131, 7133, 8130, 8131, 8133 |
Double-skin Insulated Intellicore® (exterior skin 27 ga. min.; interior skin 27 ga. min.) Single-Car (up to 9’0” wide) WINDCODE® W5 Garage Door |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +33 PSF/-37 PSF Other: The standard glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. |
Installation Instructions FL47958_R0_II_104866-Rev04.pdf Verified By: James D. Wheeler FL PE 91932 Created by Independent Third Party: No Evaluation Reports FL47958_R0_AE_CCER_251214-B-00.pdf Created by Independent Third Party: No |
|
|
| 47958.5 |
005 W5-16 DSIU-1A171: 9130, 9131, 9133, HDP13, HDPF13, HDPL13, 7130, 7131, 7133, 8130, 8131, 8133 |
Double-skin Insulated PUR (exterior skin 27 ga. min.; interior skin 27 ga. min.) Double-Car (9’2” to 16’0” wide) WINDCODE® W5 Garage Door |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +32 PSF/-32 PSF Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.2 FBC). |
Installation Instructions FL47958_R0_II_104191-Rev04.pdf Verified By: James D. Wheeler FL PE 91932 Created by Independent Third Party: No Evaluation Reports FL47958_R0_AE_CCER_251214-B-00.pdf Created by Independent Third Party: No |