Florida Building Code Online
Florida Department of Business & Professional Regulation
myFlorida Logo Town Graphic
DBPR Home Button About DBPR Button DBPR Divisions Button Contact DBPR Button
Florida Department of Business & Professional Regulation
Office of the Secretary
Product Approval
USER: Public User
 
Product Approval Menu > Application Detail
 
FL # FL47958-R0
Application Type New
Code Version 2023
Application Status Approved
 
Comments
Archived
 
Product Manufacturer Clopay Building Products Company
Address/Phone/Email 8585 Duke Blvd.
Mason, OH 45040
(513) 770-4641
jwheeler@clopay.com
 
Authorized Signature Jim Wheeler
jwheeler@clopay.com
 
Technical Representative
Address/Phone/Email
 
Quality Assurance Representative
Address/Phone/Email
 
Category Exterior Doors
Subcategory Sectional Exterior Door Assemblies
 
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Evaluation Report - Hardcopy Received
 
Florida Engineer or Architect Name who developed the Evaluation Report James D. Wheeler
Florida License PE-91932
Quality Assurance Entity Intertek Testing Services NA, Inc. - QA Entity
Quality Assurance Contract Expiration Date 12/31/2030
Validated By Gary Pfuehler
  Validation Checklist - Hardcopy Received
 
Certificate of Independence FL47958_R0_COI_Certification_of_Independence_of_Validation_Entity-Gary_Pfuehler 2016-02-19.pdf
FL47958_R0_COI_Statement_of_Independence_of_Evaluation_Entity_JDW_240626.pdf
 
Referenced Standard and Year (of Standard)
StandardYear
ANSI/DASMA 1082005
ANSI/DASMA 1152005
ASTM E18862005
ASTM E19962009
ASTM E3302002
TAS 2011994
TAS 2021994
TAS 2031994
 
Equivalence of Product Standards
Certified By

Florida Licensed Professional Engineer or Architect
FL47958_R0_Equiv_Statement_of_Equivalency_E1886-1996.pdf
FL47958_R0_Equiv_Statement_of_Equivalency_E330.pdf
 
Sections from the Code
 
 
 
Product Approval Method Method 1 Option D
 
Date Submitted 12/15/2025
Date Validated 12/15/2025
Date Pending FBC Approval 12/17/2025
Date Approved 02/10/2026
Date Revised 08/19/2026
 
Summary of Products
FL # Model, Number or Name Description
47958.1 001 W4-09 DSIU-1A171: 9130, 9131, 9133, HDP13, HDPF13, HDPL13, 7130, 7131, 7133, 8130, 8131, 8133 Double-skin Insulated PUR (exterior skin 27 ga. min.; interior skin 27 ga. min.) Single-Car (up to 9’0” wide) WINDCODE® W4 Garage Door
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +25 PSF/-28 PSF
 Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.2 FBC).
Installation Instructions
 FL47958_R0_II_104947-Rev02.pdf
 Verified By: James D. Wheeler FL PE 91932
 Created by Independent Third Party: No
Evaluation Reports
 FL47958_R0_AE_CCER_251214-B-00.pdf
 Created by Independent Third Party: No
47958.2 002 W4-16 DSIU-1A171: 9130, 9131, 9133, HDP13, HDPF13, HDPL13, 7130, 7131, 7133, 8130, 8131, 8133 Double-skin Insulated PUR (exterior skin 27 ga. min.; interior skin 27 ga. min.) Double-Car (9’2” to 16’0” wide) WINDCODE® W4 Garage Door
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +24 PSF/-26.5 PSF
 Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.2 FBC).
Installation Instructions
 FL47958_R0_II_104704-Rev02.pdf
 Verified By: James D. Wheeler FL PE 91932
 Created by Independent Third Party: No
Evaluation Reports
 FL47958_R0_AE_CCER_251214-B-00.pdf
 Created by Independent Third Party: No
47958.3 003 W4-18 DSIU-1A171: 9130, 9131, 9133, HDP13, HDPF13, HDPL13, 7130, 7131, 7133, 8130, 8131, 8133 Double-skin Insulated PUR (exterior skin 27 ga. min.; interior skin 27 ga. min.) 16'2" to 18'0" wide WINDCODE® W4 Garage Door
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +24 PSF/-26 PSF
 Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.2 FBC).
Installation Instructions
 FL47958_R0_II_104887-Rev02.pdf
 Verified By: James D. Wheeler FL PE 91932
 Created by Independent Third Party: No
Evaluation Reports
 FL47958_R0_AE_CCER_251214-B-00.pdf
 Created by Independent Third Party: No
47958.4 004 W5-09 DSIU-1A171: 9130, 9131, 9133, HDP13, HDPF13, HDPL13, 7130, 7131, 7133, 8130, 8131, 8133 Double-skin Insulated Intellicore® (exterior skin 27 ga. min.; interior skin 27 ga. min.) Single-Car (up to 9’0” wide) WINDCODE® W5 Garage Door
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +33 PSF/-37 PSF
 Other: The standard glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions.
Installation Instructions
 FL47958_R0_II_104866-Rev04.pdf
 Verified By: James D. Wheeler FL PE 91932
 Created by Independent Third Party: No
Evaluation Reports
 FL47958_R0_AE_CCER_251214-B-00.pdf
 Created by Independent Third Party: No
47958.5 005 W5-16 DSIU-1A171: 9130, 9131, 9133, HDP13, HDPF13, HDPL13, 7130, 7131, 7133, 8130, 8131, 8133 Double-skin Insulated PUR (exterior skin 27 ga. min.; interior skin 27 ga. min.) Double-Car (9’2” to 16’0” wide) WINDCODE® W5 Garage Door
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +32 PSF/-32 PSF
 Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.2 FBC).
Installation Instructions
 FL47958_R0_II_104191-Rev04.pdf
 Verified By: James D. Wheeler FL PE 91932
 Created by Independent Third Party: No
Evaluation Reports
 FL47958_R0_AE_CCER_251214-B-00.pdf
 Created by Independent Third Party: No
 
Back   Next
 
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
Product Approval Accepts:
Visa Mastercard Discover eCheck Amex