| 24508.1 |
24 Ga. Secure-Seam (Purlins) - Anchor Pattern A |
Non-structural standing seam min. 24 ga. metal roof panels installed over 1x4 purlins over nominal 15/32” plywood sheathing roof deck, w/ or w/o asphalt shingles & 30# felt paper between the purlins & the roof deck, for use in re-roofing. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-78.5 Other: |
Certification Agency Certificate FL24508_R3_C_CAC_11033-009-Rev4CertificationReport.pdf Quality Assurance Contract Expiration Date 12/22/2025 Installation Instructions FL24508_R3_II_11033-009-Rev4CertificationReport.pdf Verified By: Keystone Certifications, Inc. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 24508.2 |
24 Ga. Secure-Seam (Purlins) - Anchor Pattern B |
Non-structural standing seam min. 24 ga. metal roof panels installed over 1x4 purlins over nominal 15/32” plywood sheathing roof deck, w/ or w/o asphalt shingles & 30# felt paper between the purlins & the roof deck, for use in re-roofing. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-101.0 Other: |
Certification Agency Certificate FL24508_R3_C_CAC_11033-009-Rev4CertificationReport.pdf Quality Assurance Contract Expiration Date 12/22/2025 Installation Instructions FL24508_R3_II_11033-009-Rev4CertificationReport.pdf Verified By: Keystone Certifications, Inc. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 24508.3 |
24 Ga. Secure-Seam - Anchor Pattern A |
Non-structural standing seam minimum 24 gauge metal roof panels installed over nominal 15/32” plywood sheathing roof deck for use in new construction and re-roofing applications. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-63.5 Other: |
Certification Agency Certificate FL24508_R3_C_CAC_11033-008-Rev4CertificationReport.pdf Quality Assurance Contract Expiration Date 12/22/2025 Installation Instructions FL24508_R3_II_11033-008-Rev4CertificationReport.pdf Verified By: Keystone Certifications, Inc. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 24508.4 |
24 Ga. Secure-Seam - Anchor Pattern B |
Non-structural standing seam minimum 24 gauge metal roof panels installed over nominal 15/32” plywood sheathing roof deck for use in new construction and re-roofing applications. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-101.0 Other: |
Certification Agency Certificate FL24508_R3_C_CAC_11033-008-Rev4CertificationReport.pdf Quality Assurance Contract Expiration Date 12/22/2025 Installation Instructions FL24508_R3_II_11033-008-Rev4CertificationReport.pdf Verified By: Keystone Certifications, Inc. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 24508.5 |
26 Ga. PBR Panel (Purlins) - Anchor Pattern A |
Non-structural through fastened min. 26 ga. metal roof panels installed over 1x4 purlins over nominal 15/32" plywood roof deck w/ or w/o asphalt shingles & 30# felt paper between the purlins & the roof deck, for use in re-roofing. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-56.0 Other: |
Certification Agency Certificate FL24508_R3_C_CAC_11033-005-Rev2CertificationReport.pdf Quality Assurance Contract Expiration Date 12/22/2025 Installation Instructions FL24508_R3_II_11033-005-Rev2CertificationReport.pdf Verified By: Keystone Certifications, Inc. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 24508.6 |
26 Ga. PBR Panel (Purlins) - Anchor Pattern B |
Non-structural through fastened min. 26 ga. metal roof panels installed over 1x4 purlins over nominal 15/32" plywood roof deck w/ or w/o asphalt shingles & 30# felt paper between the purlins & the roof deck, for use in re-roofing. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-123.5 Other: |
Certification Agency Certificate FL24508_R3_C_CAC_11033-005-Rev2CertificationReport.pdf Quality Assurance Contract Expiration Date 12/22/2025 Installation Instructions FL24508_R3_II_11033-005-Rev2CertificationReport.pdf Verified By: Keystone Certifications, Inc. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 24508.7 |
26 Ga. PBR Panel - Anchor Pattern A |
Non-structural through fastened minimum 26 gauge metal roof panels installed over nominal 15/32” plywood sheathing roof deck for use in new construction and re-roofing applications. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-56.0 Other: |
Certification Agency Certificate FL24508_R3_C_CAC_11033-002Rev5CertificationReport.pdf Quality Assurance Contract Expiration Date 12/22/2025 Installation Instructions FL24508_R3_II_11033-002Rev5CertificationReport.pdf Verified By: Keystone Certifications, Inc. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 24508.8 |
26 Ga. PBR Panel - Anchor Pattern B |
Non-structural through fastened minimum 26 gauge metal roof panels installed over nominal 15/32” plywood sheathing roof deck for use in new construction and re-roofing applications. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-146.0 Other: |
Certification Agency Certificate FL24508_R3_C_CAC_11033-002Rev5CertificationReport.pdf Quality Assurance Contract Expiration Date 12/22/2025 Installation Instructions FL24508_R3_II_11033-002Rev5CertificationReport.pdf Verified By: Keystone Certifications, Inc. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 24508.9 |
26 Ga. Residential Panel (Purlins) - Anchor Pattern A |
Non-structural through fastened min. 26 ga. metal roof panels installed over 1x4 purlins over over nominal 15/32” plywood sheathing roof deck w/ or w/o asphalt shingles & 30# felt paper between the purlins & the roof deck, for use in re-roofing. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-63.5 Other: |
Certification Agency Certificate FL24508_R3_C_CAC_11033-011-Rev2-CertificationReport.pdf Quality Assurance Contract Expiration Date 12/22/2025 Installation Instructions FL24508_R3_II_11033-011-Rev2-CertificationReport.pdf Verified By: Keystone Certifications, Inc. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 24508.10 |
26 Ga. Residential Panel (Purlins) - Anchor Pattern B |
Non-structural through fastened min. 26 ga. metal roof panels installed over 1x4 purlins over over nominal 15/32” plywood sheathing roof deck w/ or w/o asphalt shingles & 30# felt paper between the purlins & the roof deck, for use in re-roofing. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-123.5 Other: |
Certification Agency Certificate FL24508_R3_C_CAC_11033-011-Rev2-CertificationReport.pdf Quality Assurance Contract Expiration Date 12/22/2025 Installation Instructions FL24508_R3_II_11033-011-Rev2-CertificationReport.pdf Verified By: Keystone Certifications, Inc. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 24508.11 |
26 Ga. Residential Panel - Anchor Pattern A |
Non-structural through-fastened minimum 26 gauge metal roof panels installed over nominal 15/32” plywood sheathing roof deck for use in new construction and re-roofing applications. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-86.0 Other: |
Certification Agency Certificate FL24508_R3_C_CAC_11033-010-Rev2-CertificationReport.pdf Quality Assurance Contract Expiration Date 12/22/2025 Installation Instructions FL24508_R3_II_11033-010-Rev2-CertificationReport.pdf Verified By: Keystone Certifications, Inc. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 24508.12 |
26 Ga. Residential Panel - Anchor Pattern B |
Non-structural through-fastened minimum 26 gauge metal roof panels installed over nominal 15/32” plywood sheathing roof deck for use in new construction and re-roofing applications. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-168.5 Other: |
Certification Agency Certificate FL24508_R3_C_CAC_11033-010-Rev2-CertificationReport.pdf Quality Assurance Contract Expiration Date 12/22/2025 Installation Instructions FL24508_R3_II_11033-010-Rev2-CertificationReport.pdf Verified By: Keystone Certifications, Inc. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 24508.13 |
26 Ga. Secure-Seam - Anchor Pattern A |
Non-structural standing seam minimum 26 gauge metal roof panels installed over nominal 15/32” plywood sheathing roof deck for use in new construction and re-roofing applications. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-56.0 Other: |
Certification Agency Certificate FL24508_R3_C_CAC_11033-003Rev5-CertificationReport.pdf Quality Assurance Contract Expiration Date 12/22/2025 Installation Instructions FL24508_R3_II_11033-003Rev5-CertificationReport.pdf Verified By: Keystone Certifications, Inc. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 24508.14 |
26 Ga. Secure-Seam - Anchor Pattern B |
Non-structural standing seam minimum 26 gauge metal roof panels installed over nominal 15/32” plywood sheathing roof deck for use in new construction and re-roofing applications. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-86.0 Other: |
Certification Agency Certificate FL24508_R3_C_CAC_11033-003Rev5-CertificationReport.pdf Quality Assurance Contract Expiration Date 12/22/2025 Installation Instructions FL24508_R3_II_11033-003Rev5-CertificationReport.pdf Verified By: Keystone Certifications, Inc. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 24508.15 |
29 Ga. Residential Panel (Purlins) - Anchor Pattern A |
Non-structural through fastened min. 29 ga. metal roof panels installed over 1x4 purlins over nominal 7/16” OSB sheathing roof deck, w/ or w/o asphalt shingles & 30# felt paper between the purlins & the roof deck, for use in re-roofing. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-86.0 Other: |
Certification Agency Certificate FL24508_R3_C_CAC_11033-007Rev3-CertificationReport.pdf Quality Assurance Contract Expiration Date 12/22/2025 Installation Instructions FL24508_R3_II_11033-007Rev3-CertificationReport.pdf Verified By: Keystone Certifications, Inc. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 24508.16 |
29 Ga. Residential Panel (Purlins) - Anchor Pattern B |
Non-structural through fastened min. 29 ga. metal roof panels installed over 1x4 purlins over nominal 7/16” OSB sheathing roof deck, w/ or w/o asphalt shingles & 30# felt paper between the purlins & the roof deck, for use in re-roofing. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-176.0 Other: |
Certification Agency Certificate FL24508_R3_C_CAC_11033-007Rev3-CertificationReport.pdf Quality Assurance Contract Expiration Date 12/22/2025 Installation Instructions FL24508_R3_II_11033-007Rev3-CertificationReport.pdf Verified By: Keystone Certifications, Inc. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 24508.17 |
29 Ga. Residential Panel - Anchor Pattern A |
Non-structural through fastened minimum 29 gauge metal roof panels installed over nominal 7/16” OSB sheathing roof deck for use in new construction and re-roofing applications. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-20.8 Other: |
Certification Agency Certificate FL24508_R3_C_CAC_11033-006Rev3-CertificationReport.pdf Quality Assurance Contract Expiration Date 12/22/2025 Installation Instructions FL24508_R3_II_11033-006Rev3-CertificationReport.pdf Verified By: Keystone Certifications, Inc. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 24508.18 |
29 Ga. Residential Panel - Anchor Pattern B |
Non-structural through fastened minimum 29 gauge metal roof panels installed over nominal 7/16” OSB sheathing roof deck for use in new construction and re-roofing applications. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-108.5 Other: |
Certification Agency Certificate FL24508_R3_C_CAC_11033-006Rev3-CertificationReport.pdf Quality Assurance Contract Expiration Date 12/22/2025 Installation Instructions FL24508_R3_II_11033-006Rev3-CertificationReport.pdf Verified By: Keystone Certifications, Inc. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |