24508.1 |
PBR Panel - Anchor Pattern A |
Non-structural through fastened minimum 26 gauge metal roof panels installed over nominal 15/32” plywood sheathing roof deck for use in new construction and re-roofing applications. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-56.0 Other: |
Certification Agency Certificate FL24508_R0_C_CAC_11033-002-CertificationReport.pdf Quality Assurance Contract Expiration Date 11/29/2022 Installation Instructions FL24508_R0_II_11033-002-CertificationReport.pdf Verified By: Keystone Certifications, Inc. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
24508.2 |
PBR Panel - Anchor Pattern B |
Non-structural through fastened minimum 26 gauge metal roof panels installed over nominal 15/32” plywood sheathing roof deck for use in new construction and re-roofing applications. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-146.0 Other: |
Certification Agency Certificate FL24508_R0_C_CAC_11033-002-CertificationReport.pdf Quality Assurance Contract Expiration Date 11/29/2022 Installation Instructions FL24508_R0_II_11033-002-CertificationReport.pdf Verified By: Keystone Certifications, Inc. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
24508.3 |
Secure-Seam - Anchor Pattern A |
Non-structural standing seam minimum 26 gauge metal roof panels installed over nominal 15/32” plywood sheathing roof deck for use in new construction and re-roofing applications. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-56.0 Other: |
Certification Agency Certificate FL24508_R0_C_CAC_11033-003-CertificationReport.pdf Quality Assurance Contract Expiration Date 11/29/2022 Installation Instructions FL24508_R0_II_11033-003-CertificationReport.pdf Verified By: Keystone Certifications, Inc. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
24508.4 |
Secure-Seam - Anchor Pattern B |
Non-structural standing seam minimum 26 gauge metal roof panels installed over nominal 15/32” plywood sheathing roof deck for use in new construction and re-roofing applications. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-86.0 Other: |
Certification Agency Certificate FL24508_R0_C_CAC_11033-003-CertificationReport.pdf Quality Assurance Contract Expiration Date 11/29/2022 Installation Instructions FL24508_R0_II_11033-003-CertificationReport.pdf Verified By: Keystone Certifications, Inc. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |