| 24510.1 |
PBR Panel - Anchor Pattern A |
Through-fastened structural metal roof panels installed over minimum 16 gauge steel purlins (spaced supports) for use in new construction and re-roofing applications. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +49.4/-41.6 Other: |
Certification Agency Certificate FL24510_R1_C_CAC_11033-001-Rev4CertificationReport.pdf Quality Assurance Contract Expiration Date 12/25/2025 Installation Instructions FL24510_R1_II_11033-001-Rev4CertificationReport.pdf Verified By: Keystone Certifications, Inc. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 24510.2 |
PBR Panel - Anchor Pattern B |
Through-fastened structural metal roof panels installed over minimum 16 gauge steel purlins (spaced supports) for use in new construction and re-roofing applications. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +156.0/-122.2 Other: |
Certification Agency Certificate FL24510_R1_C_CAC_11033-001-Rev4CertificationReport.pdf Quality Assurance Contract Expiration Date 12/25/2025 Installation Instructions FL24510_R1_II_11033-001-Rev4CertificationReport.pdf Verified By: Keystone Certifications, Inc. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 24510.3 |
Secure-Seam - Anchor Pattern A |
Secure-Seam standing seam minimum 26 gauge structural metal roof panels, nominal 14” coverage, installed over minimum 16 gauge purlins for use in new construction applications. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/-26.0 Other: |
Certification Agency Certificate FL24510_R1_C_CAC_11033-004-Rev4CertificationReport.pdf Quality Assurance Contract Expiration Date 12/22/2025 Installation Instructions FL24510_R1_II_11033-004-Rev4CertificationReport.pdf Verified By: Keystone Certifications, Inc. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 24510.4 |
Secure-Seam - Anchor Pattern B |
Secure-Seam standing seam minimum 26 gauge structural metal roof panels, nominal 14” coverage, installed over minimum 16 gauge purlins for use in new construction applications. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/--88.4 Other: |
Certification Agency Certificate FL24510_R1_C_CAC_11033-004-Rev4CertificationReport.pdf Quality Assurance Contract Expiration Date 12/22/2025 Installation Instructions FL24510_R1_II_11033-004-Rev4CertificationReport.pdf Verified By: Keystone Certifications, Inc. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |