| 20126.1 |
Series 3500 Aluminum Fixed Window |
Fixed Windows (Small & Large Missile Impact) |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +70/-70 Other: Window size, assembly and installation requirements are to be as specified in the attached drawing No. 1912. Job required design wind pressure shall be calculated in accordance with the Florida Building Code Chapter 16 and ASCE 7 Minimum Design Loads for Buildings and Other Structures. This window system is rated as a wind zone 4 missile level "D" product. All glass meets the requirements of the current ASTM E1300 Standard. |
Installation Instructions FL20126_R3_II_Drawing 1912.pdf Verified By: Warren W. Schaefer P.E. 44135 Created by Independent Third Party: Yes Evaluation Reports FL20126_R3_AE_Evaluation report WWS_291.pdf Created by Independent Third Party: Yes |