| 17353.1 |
Georgia Rib Roof Panel |
36" wide X 29 ga galv steel
#12-14 X 1" Self drill Hex Head Fastener with 5/8" dia Steel Seal Washer |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +0/-125.1 Other: Per ASTM E1592 test over open framing supports located at 2'-0" on centers with safety factor of 2.0 |
Installation Instructions FL17353_R4_II_Georgia Metals Testing and Evaluation.pdf Verified By: Farabaugh Engineering and Testing, LLC Test Reports FL17353_R4_TR_Georgia Metals Testing and Evaluation.pdf |
|
|
| 17353.2 |
Georgia Rib Roof Panel |
36" wide x 29ga galv steel Woodbinding Fastener 10x1.5" |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +0/-63.5 Other: Per UL 580 / UL 1897 test over plywood substrate with fastener spacing of 1' 6" on centers with safety factor of 2.0 |
Installation Instructions FL17353_R4_II_T146-17 GeorgiaMetals 29ga OSB.pdf Verified By: Farabaugh Engineering and Testing, LLC Test Reports FL17353_R4_TR_T146-17 GeorgiaMetals 29ga OSB.pdf |
|
|
| 17353.3 |
RPanel Roof Panel |
36" x 26ga galv steel #12-14 x 1" Self Drill hex head fastener with 5.8" dia steel seal washer |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +0/-39.0 Other: Per ASTM E1592 test over open framing supports located at 5' on centers with safety factor of 2.0 |
Installation Instructions FL17353_R4_II_T145-17 GeorgiaMetals 26ga RPanel.pdf Verified By: Farabaugh Engineering and Testing, LLC Test Reports FL17353_R4_TR_T145-17 GeorgiaMetals 26ga RPanel.pdf |