| 38740.1 |
Allura and Terraplank Fiber-Cement Lap Siding |
Traditional Cedar and Smooth |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-48.7 Other: Allura and Terraplank Fiber-Cement siding installation and design pressures are outlined in CERus-1012 Section 8.1. |
Installation Instructions FL38740_R1_II_Allura Installation Manual V220630-FL(C) (NOV-25).pdf Verified By: QAI Laboraotories Ltd Created by Independent Third Party: Evaluation Reports FL38740_R1_AE_03.CERus-1012rev5- Plycem USA LLC - Allura Fiber-Cement - 2023 FBC 06112025.pdf |
|
|
| 38740.2 |
Allura and Terraplank Fiber-Cement Panel Siding |
Stucco, CedaTraditional Cedar and Smooth Products |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-43.4 Other: Allura and Terraplank Fiber-Cement Panel Siding installation and design pressures are outlined in CERus-1012 Section 8.1. |
Installation Instructions FL38740_R1_II_Allura Installation Manual V220630-FL(C) (NOV-25).pdf Verified By: QAI Laboraotories Ltd Created by Independent Third Party: Evaluation Reports FL38740_R1_AE_03.CERus-1012rev5- Plycem USA LLC - Allura Fiber-Cement - 2023 FBC 06112025.pdf |
|
|
| 38740.3 |
Allura and Terraplank Fiber-Cement Shake Select Siding |
Random Square Straight Edge, Random Square Staggered Edge, Half Rounds, Octagon Products |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-66.7 Other: Allura and Terraplank Fiber-Cement Shake Select Siding installation and design pressures are outlined in CERus-1012 Section 8.1. |
Installation Instructions FL38740_R1_II_Allura Installation Manual V220630-FL(C) (NOV-25).pdf Verified By: QAI Laboraotories Ltd Created by Independent Third Party: Evaluation Reports FL38740_R1_AE_03.CERus-1012rev5- Plycem USA LLC - Allura Fiber-Cement - 2023 FBC 06112025.pdf |
|
|
| 38740.4 |
Allura and Terraplank Fiber-Cement Shake Siding |
Straight Edge, Staggered Edge, Half Rounds and Octagon Products |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-48.3 Other: Allura and Terraplank Fiber-Cement Shake Siding installation and design pressures are outlined in CERus-1012 Section 8.1. |
Installation Instructions FL38740_R1_II_Allura Installation Manual V220630-FL(C) (NOV-25).pdf Verified By: QAI Laboraotories Ltd Created by Independent Third Party: Evaluation Reports FL38740_R1_AE_03.CERus-1012rev5- Plycem USA LLC - Allura Fiber-Cement - 2023 FBC 06112025.pdf |