| 16270.1 |
BITEC Modified Bitumen Roof Systems |
APP and SBS modified bitumen roof systems for use in FBC non-HVHZ jurisdictions. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/-112.5 Other: 1.) The design pressure pertains to one assembly. Refer to UL TGIK Certification for all assemblies and pressures. 2.) The "Uplift Resistance" in UL TGIK listings reflects ultimate performance. Divide "Uplift Resistance" by 2 to obtain allowable design pressure. 3.) UL TGIK certification listings are limited to wind uplift resistance. This file does not purport to address codified physical property requirements of the roof membranes per FBC 1507.11.2. |
Certification Agency Certificate FL16270_R9_C_CAC_2021_02_03_BITEC_UL TGIK.13231.pdf Quality Assurance Contract Expiration Date 12/31/2030 Installation Instructions FL16270_R9_II_2021_02_03_BITEC_UL TGIK.13231.pdf Verified By: UL LLC Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |