| 16225.1 |
AV300 |
2-7/8" thick aluminum rail and stile full view sectional garage door |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +Varies/-Varies Other: Design Pressures:
14'-2" = 43.0/-48.0;
18'-2" = 32.0/-36.0 |
Installation Instructions FL16225_R19_II_P-3330-C.pdf Verified By: Scott A. Brown 65940 Created by Independent Third Party: Yes Evaluation Reports FL16225_R19_AE_Product Evaluation 38-M_s2.pdf Created by Independent Third Party: Yes |
|
|
| 16225.2 |
AV300 |
2-7/8" thick aluminum rail and stile full view sectional garage door |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +Varies/-Varies Other: Design Pressures:
8'-2" = 47.3/-53.5;
9'-2" = 42.1/-47.7;
10'-2" = 38.0/-43.0;
12'-2" = 26.5/-30.0;
14'-2" = 23.3/-25.9;
16'-2" = 20.4/-22.7;
18'-2" = 16.2/-18.0 |
Installation Instructions FL16225_R19_II_P-2434-A.pdf Verified By: Scott A. Brown 65940 Created by Independent Third Party: Yes Evaluation Reports FL16225_R19_AE_Product Evaluation 38-M_s2.pdf Created by Independent Third Party: Yes |
|
|
| 16225.3 |
AV300 |
2-7/8" thick aluminum rail and stile full view sectional garage door |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +27.8/-31.0 Other: Max door width = 20'-2". |
Installation Instructions FL16225_R19_II_P-3359-A_s.pdf Verified By: Scott A. Brown 65940 Created by Independent Third Party: Yes Evaluation Reports FL16225_R19_AE_Product Evaluation 38-M_s2.pdf Created by Independent Third Party: Yes |
|
|
| 16225.4 |
AV300 |
2-7/8" thick aluminum rail and stile full view sectional garage door |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +45.9/-51.9 Other: Max door width = 12-2" |
Installation Instructions FL16225_R19_II_P-3353-A.pdf Verified By: Scott A. Brown 65940 Created by Independent Third Party: Yes Evaluation Reports FL16225_R19_AE_Product Evaluation 38-M_s2.pdf Created by Independent Third Party: Yes |
|
|
| 16225.5 |
AV300 |
2-7/8" thick aluminum rail and stile full view sectional garage door
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +45.9/-51.9 Other: Max door width = 10-2" |
Installation Instructions FL16225_R19_II_P-3355-A_s.pdf Verified By: Scott A. Brown 65940 Created by Independent Third Party: Yes Evaluation Reports FL16225_R19_AE_Product Evaluation 38-M_s2.pdf Created by Independent Third Party: Yes |
|
|
| 16225.6 |
AV300 |
2-7/8" thick aluminum rail and stile full view sectional garage door |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +27.8/-31.0 Other: Max door width = 20'-2". |
Installation Instructions FL16225_R19_II_P-2615-B_s3.pdf Verified By: Scott A. Brown 65940 Created by Independent Third Party: Yes Evaluation Reports FL16225_R19_AE_Product Evaluation 38-M_s2.pdf Created by Independent Third Party: Yes |
|
|
| 16225.7 |
TH160 / TM175 / TM200 / TM220 |
1-5/8", 1-3/4" or 2" thick insulated steel sandwich commercial sectional garage door |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +Varies/-Varies Other: Max door width = 12-2" |
Installation Instructions FL16225_R19_II_P-2421-F_s.pdf Verified By: Scott A. Brown 65940 Created by Independent Third Party: Yes Evaluation Reports FL16225_R19_AE_Product Evaluation 38-M_s2.pdf Created by Independent Third Party: Yes |
|
|
| 16225.8 |
TH160 / TM175 / TM200 / TM220 |
1-5/8", 1-3/4" or 2" thick insulated steel sandwich commercial sectional garage door w/ optional aluminum full view sections (N/A for TH160) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +Varies/-Varies Other: See drawing for pressures. Max door width = 18'-2". |
Installation Instructions FL16225_R19_II_P-2422-F_s.pdf Verified By: Scott A. Brown 65940 Created by Independent Third Party: Yes Evaluation Reports FL16225_R19_AE_Product Evaluation 38-M_s2.pdf Created by Independent Third Party: Yes |
|
|
| 16225.9 |
TH160 / TM175 / TM200 / TM220 |
1-5/8", 1-3/4" or 2" thick insulated steel sandwich commercial sectional garage door w/ optional aluminum full view sections (N/A for TH160) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +Varies/-Varies Other: See drawing for pressures. Max door width = 20'-2". |
Installation Instructions FL16225_R19_II_P-2423-F_s.pdf Verified By: Scott A. Brown 65940 Created by Independent Third Party: Yes Evaluation Reports FL16225_R19_AE_Product Evaluation 38-M_s2.pdf Created by Independent Third Party: Yes |
|
|
| 16225.10 |
TH160 / TM175 / TM200 / TM220 |
1-5/8", 1-3/4" or 2" thick insulated steel sandwich commercial sectional garage door |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +Varies/-Varies Other: Design Pressures:
17'-2" = 16.4/-18.2;
18'-2" = 15.5/-17.2 |
Installation Instructions FL16225_R19_II_P-2424-E_s.pdf Verified By: Scott A. Brown 65940 Created by Independent Third Party: Yes Evaluation Reports FL16225_R19_AE_Product Evaluation 38-M_s2.pdf Created by Independent Third Party: Yes |
|
|
| 16225.11 |
TH160, TM175, TM200 |
1-5/8", 1-3/4" or 2" thick insulated steel sandwich commercial sectional garage door |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +Varies/-Varies Other: See drawing for pressures. Max door width = 20'-2". |
Installation Instructions FL16225_R19_II_P-2425-D_s.pdf Verified By: Scott A. Brown 65940 Created by Independent Third Party: Yes Evaluation Reports FL16225_R19_AE_Product Evaluation 38-M_s2.pdf Created by Independent Third Party: Yes |
|
|
| 16225.12 |
TH160, TM175, TM200 |
1-5/8", 1-3/4" or 2" thick insulated steel sandwich commercial sectional garage door |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +Varies/-Varies Other: Design Pressures:
16'-2" = 29.3/-32.6;
18'-2" = 23.3/-26.0 |
Installation Instructions FL16225_R19_II_P-3328-C.pdf Verified By: Scott A. Brown 65940 Created by Independent Third Party: Yes Evaluation Reports FL16225_R19_AE_Product Evaluation 38-M_s2.pdf Created by Independent Third Party: Yes |
|
|
| 16225.13 |
TM175 / TM200 / M200 / TM220 |
1-3/4" or 2" thick insulated steel sandwich commercial sectional garage door |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +Varies/-Varies Other: See drawing for pressures. Max door width = 16'-2". |
Installation Instructions FL16225_R19_II_P-2617-A_s.pdf Verified By: Scott A. Brown 65940 Created by Independent Third Party: Yes Evaluation Reports FL16225_R19_AE_Product Evaluation 38-M_s2.pdf Created by Independent Third Party: Yes |
|
|
| 16225.14 |
TM175 / TM200 / M200 / TM220 |
1-3/4" or 2" thick insulated steel sandwich commercial sectional garage door |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +Varies/-Varies Other: See drawing for pressures. Max door width = 20'-2". |
Installation Instructions FL16225_R19_II_P-2618-A_s.pdf Verified By: Scott A. Brown 65940 Created by Independent Third Party: Yes Evaluation Reports FL16225_R19_AE_Product Evaluation 38-M_s2.pdf Created by Independent Third Party: Yes |
|
|
| 16225.15 |
TM175 / TM200 / M200 / TM220 |
1-3/4" or 2" thick insulated steel sandwich commercial sectional garage door |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +Varies/-Varies Other: See drawing for pressures. Max door width = 20'-2". |
Installation Instructions FL16225_R19_II_P-2619-A_s3.pdf Verified By: Scott A. Brown 65940 Created by Independent Third Party: Yes Evaluation Reports FL16225_R19_AE_Product Evaluation 38-M_s2.pdf Created by Independent Third Party: Yes |
|
|
| 16225.16 |
TM175 / TM200 / M200 / TM220 |
1-3/4" or 2" thick insulated steel sandwich commercial sectional garage door |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +Varies/-Varies Other: See drawing for pressures. Max door width = 20'-2". |
Installation Instructions FL16225_R19_II_P-2620-A_s.pdf Verified By: Scott A. Brown 65940 Created by Independent Third Party: Yes Evaluation Reports FL16225_R19_AE_Product Evaluation 38-M_s2.pdf Created by Independent Third Party: Yes |
|
|
| 16225.17 |
TM175 / TM200 / M200 / TM220 |
1-3/4" or 2" thick insulated steel sandwich commercial sectional garage door |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +Varies/-Varies Other: See drawing for pressures. Max door width = 16'-2". |
Installation Instructions FL16225_R19_II_P-3360-A_s.pdf Verified By: Scott A. Brown 65940 Created by Independent Third Party: Yes Evaluation Reports FL16225_R19_AE_Product Evaluation 38-M_s2.pdf Created by Independent Third Party: Yes |
|
|
| 16225.18 |
TM175 / TM200 / M200 / TM220 |
1-3/4" or 2" thick insulated steel sandwich commercial sectional garage door |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +Varies/-Varies Other: See drawing for pressures. Max door width = 20'-2". |
Installation Instructions FL16225_R19_II_P-3362-A_s.pdf Verified By: Scott A. Brown 65940 Created by Independent Third Party: Yes Evaluation Reports FL16225_R19_AE_Product Evaluation 38-M_s2.pdf Created by Independent Third Party: Yes |
|
|
| 16225.19 |
TM175 / TM200 / M200 / TM220 |
1-3/4" or 2" thick insulated steel sandwich commercial sectional garage door |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +Varies/-Varies Other: See drawing for pressures. Max door width = 20'-2". |
Installation Instructions FL16225_R19_II_P-3363-A_s.pdf Verified By: Scott A. Brown 65940 Created by Independent Third Party: Yes Evaluation Reports FL16225_R19_AE_Product Evaluation 38-M_s2.pdf Created by Independent Third Party: Yes |
|
|
| 16225.20 |
TM175 / TM200 / M200 / TM220 |
1-3/4" or 2" thick insulated steel sandwich commercial sectional garage door |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +Varies/-Varies Other: See drawing for pressures. Max door width = 12'-2". |
Installation Instructions FL16225_R19_II_P-2616-B_s.pdf Verified By: Scott A. Brown 65940 Created by Independent Third Party: Yes Evaluation Reports FL16225_R19_AE_Product Evaluation 38-M_s2.pdf Created by Independent Third Party: Yes |