Florida Building Code Online
Florida Department of Business & Professional Regulation
myFlorida Logo Town Graphic
DBPR Home Button About DBPR Button DBPR Divisions Button Contact DBPR Button
Florida Department of Business & Professional Regulation
Office of the Secretary
Product Approval
USER: Public User
 
Product Approval Menu > Application Detail
 
FL # FL16296-R3
Application Type Revision
Code Version 2020
Application Status Approved
 
Comments
Archived
 
Product Manufacturer Dixie Building Supply Co., Inc.
Address/Phone/Email 4906 Hwy 45
Eight Mile, AL 36613
(800) 239-2207
FLvalidation@yahoo.com
 
Authorized Signature Norton Jason
FLvalidation@yahoo.com
 
Technical Representative
Address/Phone/Email
 
Quality Assurance Representative
Address/Phone/Email
 
Category Structural Components
Subcategory Roof Deck
 
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Evaluation Report - Hardcopy Received
 
Florida Engineer or Architect Name who developed the Evaluation Report Locke Bowden
Florida License PE-49704
Quality Assurance Entity Keystone Certifications, Inc.
Quality Assurance Contract Expiration Date 03/13/2033
Validated By Diane Marotta, P.E.
  Validation Checklist - Hardcopy Received
 
Certificate of Independence FL16296_R3_COI_FL 16296 Dixie Bldg Supplies- Roof Deck w-details-ss.pdf
 
Referenced Standard and Year (of Standard)
StandardYear
ASTM E 15922012
FM 44711992
 
Equivalence of Product Standards
Certified By

 
Sections from the Code
 
 
 
Product Approval Method Method 1 Option D
 
Date Submitted 12/09/2020
Date Validated 12/13/2020
Date Pending FBC Approval 01/06/2021
Date Approved 02/09/2021
Date Revised 10/15/2023
 
Summary of Products
FL # Model, Number or Name Description
16296.1 PBR Roof Panel 26 Ga. PBR Roof Panel over Open Framing
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +50.0 PSF/-40.0 PSF
 Other: -40.0 psf @ 5'-0" o.c., +50.0 psf @ 5'-0" o.c.The panel is a thru-fastened structural roof panel. Limitations Non-HVHZ. Engineer must evaluate the panel attachement to substrate for fastener pullout/pullover per AISI Specifications. Install per manufacturers erection details. The use of this panel for shear roof application is outside the scope of this product approval. Non-HVHZ
Installation Instructions
 FL16296_R3_II_FL 16296 Dixie Bldg Supplies- Roof Deck w-details-ss.pdf
 Verified By: Locke Bowden, P.E. 49704
 Created by Independent Third Party: Yes
Evaluation Reports
 FL16296_R3_AE_FL 16296 Dixie Bldg Supplies- Roof Deck w-details-ss.pdf
 Created by Independent Third Party: Yes
 