FL # FL16290-R19
Application Type Revision
Code Version 2026
Application Status Approved
 
Comments
Archived
 
Product Manufacturer Performance Roof Systems, Inc. A SOPREMA Group Company
Address/Phone/Email 4800 Dr. Martin Luther King Jr. Blvd.
Kansas City, MO 64130
(816) 921-0221   Ext 152
jstuhlman@performanceroofsystems.us
 
Authorized Signature Jeff Stuhlman
jstuhlman@performanceroofsystems.us
 
Technical Representative
Address/Phone/Email
 
Quality Assurance Representative
Address/Phone/Email
 
Category Roofing
Subcategory Modified Bitumen Roof System
 
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Evaluation Report - Hardcopy Received
 
Florida Engineer or Architect Name who developed the Evaluation Report Robert Nieminen
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 07/28/2028
Validated By John W. Knezevich, PE
  Validation Checklist - Hardcopy Received
 
Certificate of Independence FL16290_R19_COI_2024_07_COI_NIEMINEN.pdf
 
Referenced Standard and Year (of Standard)
StandardYear
ASTM D61622021
ASTM D61632021
ASTM D61642021
ASTM D62222023
ASTM D62232021
ASTM D62982023
ASTM D65092023
FM 44702022
FM 44742020
TAS 1142011
 
Equivalence of Product Standards
Certified By

 
Sections from the Code
 
 
 
Product Approval Method Method 1 Option D
 
Date Submitted 08/20/2026
Date Validated 08/20/2026
Date Pending FBC Approval 08/31/2026
Date Approved 10/13/2026
 
Summary of Products
FL # Model, Number or Name Description
16290.1 Derbigum Modified Bitumen Roof Systems (HVHZ) APP and SBS modified bitumen roof systems for use in FBC HVHZ jurisdictions
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: No
 Impact Resistant: N/A
 Design Pressure: +N/A/-382.5
 Other: 1.) The design pressure noted in this application pertains to one specific assembly. Refer to the PEER Appendix for all assemblies and maximum design pressures. 2.) Refer to PEER Section 5 for Limits of Use.
Installation Instructions
 FL16290_R19_II_2026_08_20_FINAL_A1_PEER-SOPPRS-008.B_HVHZ_FL16290-R19.pdf
 Verified By: Robert Nieminen PE-59166
 Created by Independent Third Party: Yes
Evaluation Reports
 FL16290_R19_AE_2026_08_20_FINAL_PEER-SOPPRS-008.B_HVHZ_FL16290-R19.pdf
 Created by Independent Third Party: Yes
16290.2 Derbigum Modified Bitumen Roof Systems (NON-HVHZ) APP and SBS modified Bitumen roof systems for use in FBC non-HVHZ jurisdictions
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-382.5
 Other: 1.) The design pressure noted in this application pertains to one specific assembly. Refer to the PEER Appendix for all assemblies and maximum design pressures. 2.) Refer to PEER Section 5 for Limits of Use.
Installation Instructions
 FL16290_R19_II_2026_08_20_FINAL_A1_PEER-SOPPRS-008.A_NON-HVHZ_FL16290-R19.pdf
 Verified By: Robert Nieminen PE-59166
 Created by Independent Third Party: Yes
Evaluation Reports
 FL16290_R19_AE_2026_08_20_FINAL_PEER-SOPPRS-008.A_NON-HVHZ_FL16290-R19.pdf
 Created by Independent Third Party: Yes
 
Back   Next
 
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
Product Approval Accepts:
Visa Mastercard Discover eCheck Amex