| 16298.1 |
1.25 Corrugated Panel |
over APA 15/32" Plywood existing and new. Thru fastened.
23-3/4" coverage |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-97.5psf Other: -67.5psf fastening 6-1/4"-6-1/4"-6-1/4"-5"
-97.5psf fastening 2-1/2"-3-3/4'-2-1/2"-3-3/4-2-1/2"-3-3/4"-2-1/2"-2-1/2" |
Installation Instructions FL16298_R3_II_FL 16298 - Dixie Bldg Supply - Metal Roofing- ss.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL16298_R3_AE_FL 16298 - Dixie Bldg Supply - Metal Roofing- ss.pdf Created by Independent Third Party: Yes |
|
|
| 16298.2 |
5 V CRIMP |
over 1X4 SYP Wood purlins over (one layer of shingles when permitted by local building department)over15/32" APA Plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-146.0PSF Other: -71.0 PSF @ 24" o.c. Fastener Pattern: 12"-12" -146.0PSF @ 24" o.c. in the flat of panels Fastener Pattern: 9.5" -2" -9.5" Install per manufacturers details. Not for use in HVHZ Zones. |
Installation Instructions FL16298_R3_II_FL 16298 - Dixie Bldg Supply - Metal Roofing- ss.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL16298_R3_AE_FL 16298 - Dixie Bldg Supply - Metal Roofing- ss.pdf Created by Independent Third Party: Yes |
|
|
| 16298.3 |
5V Crimp |
26 Ga. 5V Crimp Roof Panel over 15/32" APA Plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-116.0PSF Other: -56.0 PSF @ 24" o.c. Fastener Pattern: 12"-12". -101.0 PSF @ 24" o.c. Fastener Pattern: 9.5"-2"-9.5". -116.0 PSF @ 12" o.c. Fastener Pattern: 12"-12". Install per manufacturers details. Not for use in HVHZ Zones. |
Installation Instructions FL16298_R3_II_FL 16298 - Dixie Bldg Supply - Metal Roofing- ss.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL16298_R3_AE_FL 16298 - Dixie Bldg Supply - Metal Roofing- ss.pdf Created by Independent Third Party: Yes |
|
|
| 16298.4 |
AG Roof Panel |
Min. 29 Ga. AG Roof Panel over 15/32" APA Plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-116.0PSF Other: -71.0 PSF @ 24" o.c. Fastener Pattern: 9"-9"-9"-9". -108.5 PSF @ 24" o.c. Fastener Pattern: 6.5"-2.5"-6.5"-2.5"-6.5"-2.5"-6.5"-2.5". Install per manufacturers details. Not for use in HVHZ Zones. |
Installation Instructions FL16298_R3_II_FL 16298 - Dixie Bldg Supply - Metal Roofing- ss.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL16298_R3_AE_FL 16298 - Dixie Bldg Supply - Metal Roofing- ss.pdf Created by Independent Third Party: Yes |
|
|
| 16298.5 |
AG Roof Panel |
Min. 29 Ga. AG Roof Panel over 1x4 No. 2 SYP Wood Purlins over 15/32" APA Plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-108.0PSF Other: -86.0 PSF @ 24" o.c. Fastener Pattern: 9"-9"-9"-9" -116 PSF @ 24" o.c. Fastener Pattern: 6.5" -2.5" -6.5"-2-5"-6.5"-2.5"-6.5"-2.5". Install per manufacturers details. Not for use in HVHZ Zones. |
Installation Instructions FL16298_R3_II_FL 16298 - Dixie Bldg Supply - Metal Roofing- ss.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL16298_R3_AE_FL 16298 - Dixie Bldg Supply - Metal Roofing- ss.pdf Created by Independent Third Party: Yes |
|
|
| 16298.6 |
PBR Roof Panel |
26 Ga. PBR Roof Panel over 1x4 SYP Wood Purlins over 15/32" APA Plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-154.75 Other: -60.5 PSF @ 24" o.c. Fastener Pattern: 12"-12"-12". -154.75 PSF @ 12" o.c. thru fastened in the flat of panels Fastener Pattern: 7"-5"-&-5"-7"-5". Install per manufacturers details. Not for use in HVHZ Zones. |
Installation Instructions FL16298_R3_II_FL 16298 - Dixie Bldg Supply - Metal Roofing- ss.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL16298_R3_AE_FL 16298 - Dixie Bldg Supply - Metal Roofing- ss.pdf Created by Independent Third Party: Yes |
|
|
| 16298.7 |
PBR Roof Panel |
26 Ga. PBR Roof Panel over 15/32" APA plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-151.75 Other: -100.5 PSF @ 24" o.c. Fastener Pattern: 12"-12"-12". -151.75 PSF @ 12" o.c. thru fastened in the flat of panels Fastener Pattern: 7"-5"-7"-5"-7"-5". Install per manufacturers details. Not for use in HVHZ Zones. |
Installation Instructions FL16298_R3_II_FL 16298 - Dixie Bldg Supply - Metal Roofing- ss.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL16298_R3_AE_FL 16298 - Dixie Bldg Supply - Metal Roofing- ss.pdf Created by Independent Third Party: Yes |
|
|
| 16298.8 |
RIB 26GA |
15/32" APA PLYWOOD |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-159.25 Other: -71.75PSF @24'O.C.
-159.25PSF @12" O.C.
Install per manufacturers details.
HVHZ. USE RAS 133 |
Installation Instructions FL16298_R3_II_FL 16298 - Dixie Bldg Supply - Metal Roofing- ss.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL16298_R3_AE_FL 16298 - Dixie Bldg Supply - Metal Roofing- ss.pdf Created by Independent Third Party: Yes |
|
|
| 16298.9 |
RIB MIN 26GA |
OVER 1x4 SYP wood purlins over 15/32" APA plywood over existing and 19/32" FOR HVHZ |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-164.25 Other: -106.75PSF @24"O.C.
-164.25PSF @12" O.C.
Install per manufacturer details.
HVHZ use RAS 133. |
Installation Instructions FL16298_R3_II_FL 16298 - Dixie Bldg Supply - Metal Roofing- ss.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL16298_R3_AE_FL 16298 - Dixie Bldg Supply - Metal Roofing- ss.pdf Created by Independent Third Party: Yes |
|
|
| 16298.10 |
Tuff-Rib 26GA over Purlins |
Tuff-Rib 26GA over 2x6 SYP Wood Treated Purlins |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-67.5 Other: -52.5 psf fastening pattern 9"-9"-9"-9" @ 24" o.c.
-67.5 psf fastening pattern 6.5"-2.5"-6.5"-2.5"-6.5"-2.5"-6.5"-2.5" @ 24" o.c. |
Installation Instructions FL16298_R3_II_FL 16298 - Dixie Bldg Supply - Metal Roofing- ss.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL16298_R3_AE_FL 16298 - Dixie Bldg Supply - Metal Roofing- ss.pdf Created by Independent Third Party: Yes |