| 42379.1 |
01: 29ga or 26ga (min) Rib on 1x4 subpurlins on plywood |
29ga or 26ga (min) Rib panel on 1x4 (min) subpurlins on plywood or OSB.
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-123.5 Other: See evaluation report for details. | Approval may be used by any of the Cornerstone Building Brands entities, e.g. Fortify Building Solutions, American Building Components, Ceco Building Systems, MBCI, Metal Sales, Metallic Building Systems, Mueller, Robertson Building Systems, Star Building Systems, Union Corrugating, et al. |
Installation Instructions FL42379_R3_II_26-29ga RIB on 1x4 on Plywood or OSB.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL42379_R3_AE_26-29ga RIB on 1x4 on Plywood or OSB.pdf Created by Independent Third Party: Yes |
|
|
| 42379.2 |
02: 29ga or 26ga (min) Rib on 15/32" Plywood or 19/32 (min) plywood or 7/16" (min) OSB |
29ga or 26ga (min) Rib panel on 15/32" plywood or 19/32 (min) plywood or 7/16" (min) OSB
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-146 Other: See evaluation report for details. | Approval may be used by any of the Cornerstone Building Brands entities, e.g. Fortify Building Solutions, American Building Components, Ceco Building Systems, MBCI, Metal Sales, Metallic Building Systems, Mueller, Robertson Building Systems, Star Building Systems, Union Corrugating, et al. |
Installation Instructions FL42379_R3_II_26-29ga RIB on Plywood or OSB.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL42379_R3_AE_26-29ga RIB on Plywood or OSB.pdf Created by Independent Third Party: Yes |
|
|
| 42379.3 |
03: 29ga (min) 5V on 15/32 (min) plywood or 7/16 (min) OSB |
29ga (min) 5V on 15/32 (min) plywood or 7/16 (min) OSB
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-52.5 Other: See evaluation report for details. | Approval may be used by any of the Cornerstone Building Brands entities, e.g. Fortify Building Solutions, American Building Components, Ceco Building Systems, MBCI, Metal Sales, Metallic Building Systems, Mueller, Robertson Building Systems, Star Building Systems, Union Corrugating, et al. |
Installation Instructions FL42379_R3_II_29ga 5V on Plywood or OSB.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL42379_R3_AE_29ga 5V on Plywood or OSB.pdf Created by Independent Third Party: Yes |
|
|
| 42379.4 |
04: 26ga (min) 5V on 15/32" or 19/32 (min) plywood |
26ga (min) 5V on 15/32" or 19/32 (min) plywood
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-169 Other: See evaluation report for details. | Approval may be used by any of the Cornerstone Building Brands entities, e.g. Fortify Building Solutions, American Building Components, Ceco Building Systems, MBCI, Metal Sales, Metallic Building Systems, Mueller, Robertson Building Systems, Star Building Systems, Union Corrugating, et al. |
Installation Instructions FL42379_R3_II_26ga 5V on Plywood.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL42379_R3_AE_26ga 5V on Plywood.pdf Created by Independent Third Party: Yes |
|
|
| 42379.5 |
05: 26ga or 24ga (min) PBR on 15/32 (min) plywood |
26ga or 24ga (min) PBR on 15/32 (min) plywood
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-161.5 Other: See evaluation report for details. | Approval may be used by any of the Cornerstone Building Brands entities, e.g. Fortify Building Solutions, American Building Components, Ceco Building Systems, MBCI, Metal Sales, Metallic Building Systems, Mueller, Robertson Building Systems, Star Building Systems, Union Corrugating, et al. |
Installation Instructions FL42379_R3_II_24-26ga PBR on Plywood.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL42379_R3_AE_24-26ga PBR on Plywood.pdf Created by Independent Third Party: Yes |
|
|
| 42379.6 |
06: 26ga (min) 2.5 Corrugated on 19/32 (min) plywood |
26ga (min) 2.5 Corrugated panel with nominal 1/2" rib height on 19/32 (min) plywood
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-129.25 Other: See evaluation report for details. | Approval may be used by any of the Cornerstone Building Brands entities, e.g. Fortify Building Solutions, American Building Components, Ceco Building Systems, MBCI, Metal Sales, Metallic Building Systems, Mueller, Robertson Building Systems, Star Building Systems, Union Corrugating, et al. |
Installation Instructions FL42379_R3_II_26ga 250 COR on Plywood.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL42379_R3_AE_26ga 250 COR on Plywood.pdf Created by Independent Third Party: Yes |
|
|
| 42379.7 |
07: 26ga or 24ga (min) PBC on 15/32 (min) plywood or 7/16" (min) OSB |
26ga or 24ga (min) PBC corrugated panel with nominal 7/8" rib height on 15/32 (min) plywood or 7/16" (min) OSB
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-177.1 Other: See evaluation report for details. | Approval may be used by any of the Cornerstone Building Brands entities, e.g. Fortify Building Solutions, American Building Components, Ceco Building Systems, MBCI, Metal Sales, Metallic Building Systems, Mueller, Robertson Building Systems, Star Building Systems, Union Corrugating, et al. |
Installation Instructions FL42379_R3_II_24-26ga COR on Plywood or OSB.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL42379_R3_AE_24-26ga COR on Plywood or OSB.pdf Created by Independent Third Party: Yes |
|
|
| 42379.8 |
08: 032 aluminum PBC on 15/32 (min) plywood |
Nominally 0.032 aluminum or thicker PBC corrugated panel with nominal 7/8" rib height on 15/32 (min) plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-164.6 Other: See evaluation report for details. | Approval may be used by any of the Cornerstone Building Brands entities, e.g. Fortify Building Solutions, American Building Components, Ceco Building Systems, MBCI, Metal Sales, Metallic Building Systems, Mueller, Robertson Building Systems, Star Building Systems, Union Corrugating, et al. |
Installation Instructions FL42379_R3_II_032 COR on Plywood.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL42379_R3_AE_032 COR on Plywood.pdf Created by Independent Third Party: Yes |