| 42394.1 |
TS-324 |
Min 24 ga., 24" wide standing seam roof panel over open supports |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-183.3 Other: Maximum uplift load of 183.3 psf @ support spacing of 24" o.c. with BA Series clips and QuadLok seam |
Installation Instructions FL42394_R0_II_EvaluationReportC2733_1.pdf Verified By: Bala Sockalingam PE 62240 Created by Independent Third Party: Yes Evaluation Reports FL42394_R0_AE_EvaluationReportC2733_1.pdf Created by Independent Third Party: Yes |
|
|
| 42394.2 |
VS-216 |
Max 16" wide, min 24 ga. standing seam panel over open supports |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-235 Other: Maximum uplift load of 235 psf at support spacing of 24" o.c. with MPS 1200 Series clips and QuadLok seam |
Installation Instructions FL42394_R0_II_EvaluationReportC2733_2.pdf Verified By: Bala Sockalingam PE 62240 Created by Independent Third Party: Yes Evaluation Reports FL42394_R0_AE_EvaluationReportC2733_2.pdf Created by Independent Third Party: Yes |