| 42380.1 |
01: Steel PermaLok on plywood |
26ga (min) PermaLok on 15/32" (min) plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-63.5 Other: See evaluation report for details. | Approval may be used by any of the Cornerstone Building Brands entities, e.g. Fortify Building Solutions, American Building Components, Ceco Building Systems, MBCI, Metal Sales, Metallic Building Systems, Mueller, Robertson Building Systems, Star Building Systems, Union Corrugating, et al. |
Installation Instructions FL42380_R3_II_26ga PermaLok on Plywood.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL42380_R3_AE_26ga PermaLok on Plywood.pdf Created by Independent Third Party: Yes |
|
|
| 42380.2 |
02: Aluminum PermaLok on plywood |
Nominally 0.032 aluminum or thicker PermaLok on 15/32" (min) plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-78.5 Other: See evaluation report for details. | Approval may be used by any of the Cornerstone Building Brands entities, e.g. Fortify Building Solutions, American Building Components, Ceco Building Systems, MBCI, Metal Sales, Metallic Building Systems, Mueller, Robertson Building Systems, Star Building Systems, Union Corrugating, et al. |
Installation Instructions FL42380_R3_II_032 PermaLok on Plywood.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL42380_R3_AE_032 PermaLok on Plywood.pdf Created by Independent Third Party: Yes |
|
|
| 42380.3 |
03: Steel nailstrip on plywood or OSB |
26ga (min) nailstrip on 15/32" (min) plywood or 7/16" (min) OSB or 3/4 wood plank |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-131.5 Other: See evaluation report for details. | Approval may be used by any of the Cornerstone Building Brands entities, e.g. Fortify Building Solutions, American Building Components, Ceco Building Systems, MBCI, Metal Sales, Metallic Building Systems, Mueller, Robertson Building Systems, Star Building Systems, Union Corrugating, et al. |
Installation Instructions FL42380_R3_II_26ga Nailstrip on Plywood.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL42380_R3_AE_26ga Nailstrip on Plywood.pdf Created by Independent Third Party: Yes |
|
|
| 42380.4 |
04: Aluminum nailstrip on plywood or OSB |
Nominally 0.032" or thicker aluminum nailstrip on 15/32" (min) plywood or 7/16" (min) OSB or 3/4 wood plank |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-93.5 Other: See evaluation report for details. | Approval may be used by any of the Cornerstone Building Brands entities, e.g. Fortify Building Solutions, American Building Components, Ceco Building Systems, MBCI, Metal Sales, Metallic Building Systems, Mueller, Robertson Building Systems, Star Building Systems, Union Corrugating, et al. |
Installation Instructions FL42380_R3_II_032 Nailstrip on Plywood.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL42380_R3_AE_032 Nailstrip on Plywood.pdf Created by Independent Third Party: Yes |
|
|
| 42380.5 |
05: Steel Slimline/SL-16 on plywood |
26ga (min) Slimline/SL-16 on 15/32" (min) plywood or 3/4" wood plank
|
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-108.5 Other: See evaluation report for details. | Approval may be used by any of the Cornerstone Building Brands entities, e.g. Fortify Building Solutions, American Building Components, Ceco Building Systems, MBCI, Metal Sales, Metallic Building Systems, Mueller, Robertson Building Systems, Star Building Systems, Union Corrugating, et al. |
Installation Instructions FL42380_R3_II_26ga Slimline SL16 on Plywood HVHZ.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL42380_R3_AE_26ga Slimline SL16 on Plywood HVHZ.pdf Created by Independent Third Party: Yes |
|
|
| 42380.6 |
06: Steel SL-150 on plywood |
24ga (min) SL-150 on 15/32" (min) plywood or 3/4" wood plank |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-116 Other: See evaluation report for details. | Approval may be used by any of the Cornerstone Building Brands entities, e.g. Fortify Building Solutions, American Building Components, Ceco Building Systems, MBCI, Metal Sales, Metallic Building Systems, Mueller, Robertson Building Systems, Star Building Systems, Union Corrugating, et al. |
Installation Instructions FL42380_R3_II_24ga SL150 on Plywood.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL42380_R3_AE_24ga SL150 on Plywood.pdf Created by Independent Third Party: Yes |
|
|
| 42380.7 |
07: Steel SL-150 on steel deck |
24ga (min) SL-150 on 22ga (min) steel B-deck or similar |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-97 Other: See evaluation report for details. | Approval may be used by any of the Cornerstone Building Brands entities, e.g. Fortify Building Solutions, American Building Components, Ceco Building Systems, MBCI, Metal Sales, Metallic Building Systems, Mueller, Robertson Building Systems, Star Building Systems, Union Corrugating, et al. |
Installation Instructions FL42380_R3_II_24ga SL150 on 22ga Deck.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL42380_R3_AE_24ga SL150 on 22ga Deck.pdf Created by Independent Third Party: Yes |
|
|
| 42380.8 |
08: Aluminum SL-150 on plywood or OSB |
Nominally 0.032" aluminum or thicker SL-150 on 15/32" (min) plywood, 7/16" (min) OSB, or 3/4" wood plank |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-86 Other: See evaluation report for details. | Approval may be used by any of the Cornerstone Building Brands entities, e.g. Fortify Building Solutions, American Building Components, Ceco Building Systems, MBCI, Metal Sales, Metallic Building Systems, Mueller, Robertson Building Systems, Star Building Systems, Union Corrugating, et al. |
Installation Instructions FL42380_R3_II_032 SL150 on Plywood.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL42380_R3_AE_032 SL150 on Plywood.pdf Created by Independent Third Party: Yes |
|
|
| 42380.9 |
09: Steel SL-175 on plywood |
24ga (min) SL-175 on 15/32" (min) plywood or 3/4" wood plank |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-93.5 Other: See evaluation report for details. | Approval may be used by any of the Cornerstone Building Brands entities, e.g. Fortify Building Solutions, American Building Components, Ceco Building Systems, MBCI, Metal Sales, Metallic Building Systems, Mueller, Robertson Building Systems, Star Building Systems, Union Corrugating, et al. |
Installation Instructions FL42380_R3_II_24ga SL175 on Plywood.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL42380_R3_AE_24ga SL175 on Plywood.pdf Created by Independent Third Party: Yes |
|
|
| 42380.10 |
10: Steel SL-175 on steel deck |
24ga (min) SL-175 on 22ga (min) steel B-deck or similar |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-86 Other: See evaluation report for details. | Approval may be used by any of the Cornerstone Building Brands entities, e.g. Fortify Building Solutions, American Building Components, Ceco Building Systems, MBCI, Metal Sales, Metallic Building Systems, Mueller, Robertson Building Systems, Star Building Systems, Union Corrugating, et al. |
Installation Instructions FL42380_R3_II_24ga SL175 on 22ga Deck.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL42380_R3_AE_24ga SL175 on 22ga Deck.pdf Created by Independent Third Party: Yes |
|
|
| 42380.11 |
11: Aluminum SL-175 on plywood |
Nominally 0.032" aluminum or thicker SL-175 on 15/32" (min) plywood or 3/4" wood plank |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-93.5 Other: See evaluation report for details. | Approval may be used by any of the Cornerstone Building Brands entities, e.g. Fortify Building Solutions, American Building Components, Ceco Building Systems, MBCI, Metal Sales, Metallic Building Systems, Mueller, Robertson Building Systems, Star Building Systems, Union Corrugating, et al. |
Installation Instructions FL42380_R3_II_032 SL175 on Plywood.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL42380_R3_AE_032 SL175 on Plywood.pdf Created by Independent Third Party: Yes |
|
|
| 42380.12 |
12: Steel Secure Seam on plywood |
24ga (min) Secure Seam on 15/32" (min) plywood or 3/4" wood plank |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-101 Other: See evaluation report for details. | Approval may be used by any of the Cornerstone Building Brands entities, e.g. Fortify Building Solutions, American Building Components, Ceco Building Systems, MBCI, Metal Sales, Metallic Building Systems, Mueller, Robertson Building Systems, Star Building Systems, Union Corrugating, et al. |
Installation Instructions FL42380_R3_II_24ga SecureSeam on Plywood.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL42380_R3_AE_24ga SecureSeam on Plywood.pdf Created by Independent Third Party: Yes |
|
|
| 42380.13 |
13: Steel Secure Seam on wood purlins on plywood |
24ga (min) Secure Seam on wood purlins (min 1x4) on 15/32" (min) plywood or 3/4" wood plank |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-101 Other: See evaluation report for details. | Approval may be used by any of the Cornerstone Building Brands entities, e.g. Fortify Building Solutions, American Building Components, Ceco Building Systems, MBCI, Metal Sales, Metallic Building Systems, Mueller, Robertson Building Systems, Star Building Systems, Union Corrugating, et al. |
Installation Instructions FL42380_R3_II_24ga SecureSeam on 1x4s on Plywood HVHZ.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL42380_R3_AE_24ga SecureSeam on 1x4s on Plywood HVHZ.pdf Created by Independent Third Party: Yes |
|
|
| 42380.14 |
14: Aluminum Secure Seam on plywood |
Nominally 0.032" aluminum or thicker Secure Seam on 15/32" (min) plywood or 3/4" wood plank |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-93.5 Other: See evaluation report for details. | Approval may be used by any of the Cornerstone Building Brands entities, e.g. Fortify Building Solutions, American Building Components, Ceco Building Systems, MBCI, Metal Sales, Metallic Building Systems, Mueller, Robertson Building Systems, Star Building Systems, Union Corrugating, et al. |
Installation Instructions FL42380_R3_II_032 SecureSeam on Plywood.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL42380_R3_AE_032 SecureSeam on Plywood.pdf Created by Independent Third Party: Yes |
|
|
| 42380.15 |
15: Steel LokSeam on plywood |
24ga (min) LokSeam on 15/32" (min) plywood or 3/4" wood plank |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-101 Other: See evaluation report for details. | Approval may be used by any of the Cornerstone Building Brands entities, e.g. Fortify Building Solutions, American Building Components, Ceco Building Systems, MBCI, Metal Sales, Metallic Building Systems, Mueller, Robertson Building Systems, Star Building Systems, Union Corrugating, et al. |
Installation Instructions FL42380_R3_II_24ga LokSeam on Plywood.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL42380_R3_AE_24ga LokSeam on Plywood.pdf Created by Independent Third Party: Yes |
|
|
| 42380.16 |
16: Steel LokSeam on steel deck |
24ga (min) LokSeam on 22ga (min) steel B-deck or similar |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-153.5 Other: See evaluation report for details. | Approval may be used by any of the Cornerstone Building Brands entities, e.g. Fortify Building Solutions, American Building Components, Ceco Building Systems, MBCI, Metal Sales, Metallic Building Systems, Mueller, Robertson Building Systems, Star Building Systems, Union Corrugating, et al. |
Installation Instructions FL42380_R3_II_24ga LokSeam on 22ga Deck.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL42380_R3_AE_24ga LokSeam on 22ga Deck.pdf Created by Independent Third Party: Yes |
|
|
| 42380.17 |
17: Steel LokSeam on plywood |
24ga (min) LokSeam on 19/32" (min) plywood or 3/4" wood plank |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-93.5 Other: See evaluation report for details. | Approval may be used by any of the Cornerstone Building Brands entities, e.g. Fortify Building Solutions, American Building Components, Ceco Building Systems, MBCI, Metal Sales, Metallic Building Systems, Mueller, Robertson Building Systems, Star Building Systems, Union Corrugating, et al. |
Installation Instructions FL42380_R3_II_24ga LokSeam on Plywood HVHZ.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL42380_R3_AE_24ga LokSeam on Plywood HVHZ.pdf Created by Independent Third Party: Yes |