| 4236.1 |
DL 15 |
Double-Lock 15 Metal Roof Panel
24 Ga., 1-1/2" Rib, 17" wide over 22 Ga. Metal Deck
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/-52.5PSF Other: -52.5 psf @ 30" o.c. clip spacing. Install per manufacturer's details. Not for use in HVHZ Zones. |
Installation Instructions FL4236_R8_II_DL 15 24 Ga. over Steel Deck.pdf Verified By: Johnathan E Green, P.E. 88223 Created by Independent Third Party: Yes Evaluation Reports FL4236_R8_AE_DL 15 24 Ga. over Steel Deck.pdf Created by Independent Third Party: Yes |
|
|
| 4236.2 |
IL 20 |
Inter-lock 20 Metal Roof Panel
24 Ga. 1-3/4" Rib, 18" wide over 22 Ga. Metal Deck |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/-52.5PSF Other: -52.5 psf @ 48" o.c. clip spacing. Install per manufacturer's details. Not for use in HVHZ Zones. |
Installation Instructions FL4236_R8_II_IL 20 24 Ga. over Steel Deck.pdf Verified By: Johnathan E Green, P.E. 88223 Created by Independent Third Party: Yes Evaluation Reports FL4236_R8_AE_IL 20 24 Ga. over Steel Deck.pdf Created by Independent Third Party: Yes |
|
|
| 4236.3 |
IL 20 |
Inter-lock 20 Metal Roof Panel
24 Ga., 1-3/4" Rib, 18" wide over 19/32" Plywood/OSB |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/-52.5PSF Other: -52.5 psf @ 30" o.c. clip spacing. Install per manufacturer's details. Not for use in HVHZ Zones. |
Installation Instructions FL4236_R8_II_IL 20 24 Ga. over Plywood.pdf Verified By: Johnathan E Green, P.E. 88223 Created by Independent Third Party: Yes Evaluation Reports FL4236_R8_AE_IL 20 24 Ga. over Plywood.pdf Created by Independent Third Party: Yes |
|
|
| 4236.4 |
SL 20 |
Span-Lock 20 Metal Roof Panel
24 Ga., 2" Rib, 18" Wide over 22 Ga. Metal Deck
Non-HVHZ |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/-52.5PSF Other: -52.5 psf @ 48" o.c. clip spacing. Install per manufacturer's details. Not for use in HVHZ Zones. |
Installation Instructions FL4236_R8_II_SL 20 24 Ga. over Steel Deck.pdf Verified By: Johnathan E Green, P.E. 88223 Created by Independent Third Party: Yes Evaluation Reports FL4236_R8_AE_SL 20 24 Ga. over Steel Deck.pdf Created by Independent Third Party: Yes |
|
|
| 4236.5 |
SL 2016 |
Span-Lock SL 2016 24 Ga. 16" wide Roof Panel over 22 Ga. Metal Deck |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/-52.5PSF Other: -52.5psf @ 48"o.c. clip spacing. Install per manufacturer's details. Not for use in HVHZ Zones. |
Installation Instructions FL4236_R8_II_SL 2016 24 Ga. over Steel Deck.pdf Verified By: Johnathan E Green, P.E. 88223 Created by Independent Third Party: Yes Evaluation Reports FL4236_R8_AE_SL 2016 24 Ga. over Steel Deck.pdf Created by Independent Third Party: Yes |
|
|
| 4236.6 |
SS 10 |
Snap-On-Seam Metal Roof Panel
24 Ga. 1" Tall, 16" wide over 19/32" SEALED Plywood/OSB
Non-HVHZ |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/-52.5PSF Other: -52.5 psf @ 20" o.c. clip spacing. Install per manufacturer's details. Not for use in HVHZ Zones. |
Installation Instructions FL4236_R8_II_SS 10 24 Ga. over Plywood and OSB.pdf Verified By: Johnathan E Green, P.E. 88223 Created by Independent Third Party: Yes Evaluation Reports FL4236_R8_AE_SS 10 24 Ga. over Plywood and OSB.pdf Created by Independent Third Party: Yes |