FL # FL42363-R2
Application Type Revision
Code Version 2023
Application Status Approved
 
Comments
Archived
 
Product Manufacturer BAKER METAL WORKS & SUPPLY, INC.
Address/Phone/Email 5846 Hwy 189
BAKER, FL 32531
(850) 537-2010
flvalidation@yahoo.com
 
Authorized Signature JASON NORTON
flvalidation@yahoo.com
 
Technical Representative
Address/Phone/Email
 
Quality Assurance Representative
Address/Phone/Email
 
Category Roofing
Subcategory Metal Roofing
 
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Evaluation Report - Hardcopy Received
 
Florida Engineer or Architect Name who developed the Evaluation Report Scott Wolters
Florida License PE-62354
Quality Assurance Entity Keystone Certifications, Inc.
Quality Assurance Contract Expiration Date 04/13/2027
Validated By Lucas A. Turner, P.E., MBA
  Validation Checklist - Hardcopy Received
 
Certificate of Independence FL42363_R2_COI_Bkr COI.pdf
 
Referenced Standard and Year (of Standard)
StandardYear
UL 18972015
UL 5802006
 
Equivalence of Product Standards
Certified By

 
Sections from the Code
 
 
 
Product Approval Method Method 1 Option D
 
Date Submitted 02/27/2024
Date Validated 03/07/2024
Date Pending FBC Approval 03/09/2024
Date Approved 04/16/2024
 
Summary of Products
FL # Model, Number or Name Description
42363.1 1 1/4" Corrugated 26 Ga. Steel Roof Panel 26 Ga. 1 1/4" Steel Corrugated Roof Panel, 23 3/4" Wide x 1/4", over 1/2" Plywood (or) 5/8" Plywood (or) 7/16" OSB with 1x4 Wood Battens.
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: N/A
 Other: Please see Installation Drawings and Eval Report for Limits of Use.
Installation Instructions
 FL42363_R2_II_B14Cor Dwg2.pdf
 Verified By: Scott Wolters FLPE# 62354
 Created by Independent Third Party: Yes
Evaluation Reports
 FL42363_R2_AE_B14Cor Eval2.pdf
 Created by Independent Third Party: Yes
42363.2 2 1/2" Corrugated 26 Ga.Steel Roof Panel 26 Ga. Steel 2 1/2" Corrugated Roof Panel, 21 1/2" Wide x 1/2", over 1/2" Plywood with 1x4 Wood Battens (or) 7/16" OSB with 1x4 Wood Battens.
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: N/A
 Other: Please see Installation Drawings and Eval Report for Limits of Use.
Installation Instructions
 FL42363_R2_II_BCorWB Dwg.pdf
 Verified By: Scott Wolters FLPE# 62354
 Created by Independent Third Party: Yes
Evaluation Reports
 FL42363_R2_AE_BCorWB Eval.pdf
 Created by Independent Third Party: Yes
42363.3 2 1/2" Corrugated 26 Ga.Steel Roof Panel 26 Ga. Steel 2 1/2" Corrugated Roof Panel, 21 1/2" Wide x 1/2", over 1/2" Plywood (or) 5/8" Plywood.
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: N/A
 Other: Please see Installation Drawings and Eval Report for Limits of Use.
Installation Instructions
 FL42363_R2_II_BCor Dwg3.pdf
 Verified By: Scott Wolters FLPE# 62354
 Created by Independent Third Party: Yes
Evaluation Reports
 FL42363_R2_AE_BCor Eval3.pdf
 Created by Independent Third Party: Yes
42363.4 26 Ga. Steel 5V Roof Panel 26 Ga. Steel 5V Roof Panel, 24" Wide x 3/8" Rib Height, over 1/2" Plywood (or) 5/8" Plywood (or) 7/16" OSB with 1x4 Wood Battens.
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: N/A
 Other: Please see Installation Drawings and Eval Report for Limits of Use.
Installation Instructions
 FL42363_R2_II_B5V Dwg2.pdf
 Verified By: Scott Wolters FLPE# 62354
 Created by Independent Third Party: Yes
Evaluation Reports
 FL42363_R2_AE_B5V Eval2.pdf
 Created by Independent Third Party: Yes
42363.5 26 Ga. Steel PBR Roof Panel 26 Ga. Steel PBR Roof Panel, 36" Wide x 1 1/4" Rib Height, over 1/2" Plywood (or) 5/8" Plywood (or) 7/16" OSB with 1x4 Wood Battens.
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: N/A
 Other: Please see Installation Drawings and Eval Report for Limits of Use.
Installation Instructions
 FL42363_R2_II_BPBR Dwg2.pdf
 Verified By: Scott Wolters FLPE# 62354
 Created by Independent Third Party: Yes
Evaluation Reports
 FL42363_R2_AE_BPBR Eval2.pdf
 Created by Independent Third Party: Yes
42363.6 26 Ga. Steel Tuff Rib Roof Panel 26 Ga. Steel Tuff Rib Roof Panel, 36" Wide x 3/4" Rib Height, over 1/2" Plywood (or) 5/8" Plywood (or) 7/16" OSB with 1x4 Wood Battens.
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: N/A
 Other: Please see Installation Drawings and Eval Report for Limits of Use.
Installation Instructions
 FL42363_R2_II_BTR Dwg.pdf
 Verified By: Scott Wolters FLPE# 62354
 Created by Independent Third Party: Yes
Evaluation Reports
 FL42363_R2_AE_BTR Eval.pdf
 Created by Independent Third Party: Yes
42363.7 29 Ga. Steel Tuff Rib Roof Panel 29 Ga, Steel Tuff Rib Roof Panel, 36" Wide x 3/4" Rib Height, over 1/2" Plywood (or) 5/8" Plywood (or) 7/16" OSB with 1x4 Wood Battens.
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: N/A
 Other: Please see Installation Drawings and Eval Report for Limits of Use.
Installation Instructions
 FL42363_R2_II_B29TR Dwg.pdf
 Verified By: Scott Wolters FLPE# 62354
 Created by Independent Third Party: Yes
Evaluation Reports
 FL42363_R2_AE_B29TR Eval.pdf
 Created by Independent Third Party: Yes
42363.8 Strongman 26 Ga. Steel Roof Panel 26 Ga. Steel Strongman Roof Panel, 36" Wide x 9/16" Rib Height, over 1/2" Plywood (or) 5/8" Plywood (or) 7/16" OSB with 1x4 Wood Battens.
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: N/A
 Other: Please see Installation Drawings and Eval Report for Limits of Use.
Installation Instructions
 FL42363_R2_II_BStM Dwg3.pdf
 Verified By: Scott Wolters FLPE# 62354
 Created by Independent Third Party: Yes
Evaluation Reports
 FL42363_R2_AE_BStM Eval3.pdf
 Created by Independent Third Party: Yes
 
Back   Next
 