| 14124.1 |
UCAVP 4072 |
Ultimate Casement Venting Picture 407-H-1047 |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +40/-40 Other: Max Size 40 x 71 1/8" (1016mm x 1807mm), Glass complies with ASTM E1300. When products are installed in areas within 3,000 ft (914 m) of a saltwater coastline, fasteners shall comply with Section 1711.1.1 and connectors shall comply with Section 1711.1.2 as stated in FBC 9th Edition (2026). |
Certification Agency Certificate FL14124_R7_C_CAC_1047.20.pdf Quality Assurance Contract Expiration Date 05/02/2033 Installation Instructions FL14124_R7_II_71460.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 14124.2 |
UCAVP 4096 |
Ultimate Casement Venting Picture 407-H-1047 |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +40/-40 Other: Max Size 40 x 95 1/8" (1016mm x 2416mm), Glass complies with ASTM E1300. When products are installed in areas within 3,000 ft (914 m) of a saltwater coastline, fasteners shall comply with Section 1711.1.1 and connectors shall comply with Section 1711.1.2 as stated in FBC 9th Edition (2026). |
Certification Agency Certificate FL14124_R7_C_CAC_1047.23.pdf Quality Assurance Contract Expiration Date 04/28/2033 Installation Instructions FL14124_R7_II_71460.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 14124.3 |
UCAVP 4872 |
Ultimate Casement Venting Picture 407-H-1047 |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +40/-40 Other: Max Size 48 x 71 1/8" (1219mm x 1807mm), Glass complies with ASTM E1300. When products are installed in areas within 3,000 ft (914 m) of a saltwater coastline, fasteners shall comply with Section 1711.1.1 and connectors shall comply with Section 1711.1.2 as stated in FBC 9th Edition (2026). |
Certification Agency Certificate FL14124_R7_C_CAC_1047.21.pdf Quality Assurance Contract Expiration Date 05/01/2033 Installation Instructions FL14124_R7_II_71460.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 14124.4 |
UCAVP 7248 |
Ultimate Casement Venting Picture 407-H-1047 |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +40/-40 Other: Max Size 72 x 47 1/8" (1829mm x 1197mm), Glass complies with ASTM E1300. When products are installed in areas within 3,000 ft (914 m) of a saltwater coastline, fasteners shall comply with Section 1711.1.1 and connectors shall comply with Section 1711.1.2 as stated in FBC 9th Edition (2026). |
Certification Agency Certificate FL14124_R7_C_CAC_1047.22.pdf Quality Assurance Contract Expiration Date 05/02/2033 Installation Instructions FL14124_R7_II_71460.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 14124.5 |
UCAVP 7272 |
Ultimate Casement Venting Picture 407-H-1047 |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +40/-40 Other: Max Size 72 x 71 1/8" (1829mm x 1807mm), Glass complies with ASTM E1300. When products are installed in areas within 3,000 ft (914 m) of a saltwater coastline, fasteners shall comply with Section 1711.1.1 and connectors shall comply with Section 1711.1.2 as stated in FBC 9th Edition (2026). |
Certification Agency Certificate FL14124_R7_C_CAC_1047.24.pdf Quality Assurance Contract Expiration Date 05/02/2033 Installation Instructions FL14124_R7_II_71460.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |