| 8393.1 |
1.0 NS (DISCONTINED) |
1.0 NS 24 Ga. 16" Coverage Roof Panel over 19/32" SEALED Plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-52.5psf Other: -52.5 psf @ 16" o.c. fastener spacing. Install per manufacturers details and in compliance with Current FBC
Not for use in HVHZ Zones. |
Installation Instructions FL8393_R8_II_NSSRn 2023 FL 8393 REPORTS AND DETAILS.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL8393_R8_AE_NSSRn 2023 FL 8393 REPORTS AND DETAILS.pdf Created by Independent Third Party: Yes |
|
|
| 8393.2 |
1.5 NS (DISCONTINUED) |
1.5 NS 24 Ga. 14 1/2" Coverage Roof Panel over 19/32" Plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-52.5 psf Other: -52.5 psf @ 18" o.c. fastener spacing. Install per manufacturers details and in compliance with Current FBC .
Not for use in HVHZ Zones. |
Installation Instructions FL8393_R8_II_NSSRn 2023 FL 8393 REPORTS AND DETAILS.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL8393_R8_AE_NSSRn 2023 FL 8393 REPORTS AND DETAILS.pdf Created by Independent Third Party: Yes |
|
|
| 8393.3 |
5V Crimp |
Minimum 24 Ga. 5V Crimp Roof Panel over 1X4 Purlins over 15/32" and 19/32" Plywood |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-108.5psf Other: -108.5 psf @ 12" o.c. fasterner spacing -156.5 psf @ 6" fastener spacing over 1X4 purlins over min. 15/32" Plywood for existing construction and min. 19/32" Plywood for new construction Install per manufacturers details and in compliance with Current FBC for use in HVHZ and NON-HVHZ Zones. |
Installation Instructions FL8393_R8_II_NSSRn 2023 FL 8393 REPORTS AND DETAILS.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL8393_R8_AE_NSSRn 2023 FL 8393 REPORTS AND DETAILS.pdf Created by Independent Third Party: Yes |
|
|
| 8393.4 |
5V Crimp |
26 Ga. 5V Crimp Roof Panel over 19/32" SEALED Plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-52.5psf Other: -52.5 psf @ 36" o.c. fastener spacing. Fastener pattern 9"-2"-9". Install per manufacturers details in compliance with Current FBC . Not for use in HVHZ Zones. |
Installation Instructions FL8393_R8_II_NSSRn 2023 FL 8393 REPORTS AND DETAILS.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL8393_R8_AE_NSSRn 2023 FL 8393 REPORTS AND DETAILS.pdf Created by Independent Third Party: Yes |
|
|
| 8393.5 |
5V Crimp-HVHZ |
5V Crimp 24 Ga. Roof Panel over 1X4 purlins over 15/32" and 19/32" SEALED Plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: No Impact Resistant: N/A Design Pressure: +N/A/-108.5psf Other: -108.5 psf @ 12"o.c. fastener spacing. -156.5 psf @ 6" o.c. fastener spacing over 1X4 purlins over min. 15/32" plywood for existing construction and min.19/32" Plywood for new construction Install per manufacturers details and in compliance with Current FBC . for use in HVHZ and NON-HVHZ Zones. |
Installation Instructions FL8393_R8_II_NSSRn 2023 FL 8393 REPORTS AND DETAILS.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL8393_R8_AE_NSSRn 2023 FL 8393 REPORTS AND DETAILS.pdf Created by Independent Third Party: Yes |
|
|
| 8393.6 |
5V Crimp-HVHZ |
26 Ga. 5V Crimp Roof Panel over 15/32" Plywood |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-156.5PSF Other: -108.5PSF @12" o.c. fastener spacing.
-156.5 PSF @ 6" o.c. fastener spacing.
Min. 15/32" plywood for existing construction and min. 19/32" for new construction. Install per manufacturers details and in compliance with Current FBC .
For use in HVHZ Zones. |
Installation Instructions FL8393_R8_II_NSSRn 2023 FL 8393 REPORTS AND DETAILS.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL8393_R8_AE_NSSRn 2023 FL 8393 REPORTS AND DETAILS.pdf Created by Independent Third Party: Yes |
|
|
| 8393.7 |
Mar-Rib |
Mar-Rib 29 Ga. Roof Panel over 15/32" Plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-52.5psf Other: -52.5 psf @ 12" o.c. fastener pattern 9"-9"-9"-9". Install per manufactuers details and in compliance with Current FBC .
Not for use in HVHZ Zones. |
Installation Instructions FL8393_R8_II_NSSRn 2023 FL 8393 REPORTS AND DETAILS.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL8393_R8_AE_NSSRn 2023 FL 8393 REPORTS AND DETAILS.pdf Created by Independent Third Party: Yes |
|
|
| 8393.8 |
Mar-Rib |
Mar-Rib 29 Ga. Roof Panel over 19/32" SEALED Plywood or 2x4 Wood Lathing |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-52.5psf Other: -52.5 psf @ 24" o.c. fastener pattern 9"-9"-9"-9". Install per manufacturers details and in compliance with Current FBC . Not for use in HVHZ Zones. |
Installation Instructions FL8393_R8_II_NSSRn 2023 FL 8393 REPORTS AND DETAILS.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL8393_R8_AE_NSSRn 2023 FL 8393 REPORTS AND DETAILS.pdf Created by Independent Third Party: Yes |
|
|
| 8393.9 |
PBR-HVHZ |
26 Ga. PBR Roof Panel over 15/32" plywood |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-154.7psf Other: Main Field-Pressure: -60.5 psf @ 12"-12"-12" fastener pattern @ 24" o.c. fastener spacing. Preimeter and Corner Pressure:
-154.75 psf @ 7"-5"-7"-5"-7"-5" fastener patter @ 12" o.c. fastener spacing. Install per manufacturers details and in compliance with Current FBC .
For use in HVHZ Zones. |
Installation Instructions FL8393_R8_II_NSSRn 2023 FL 8393 REPORTS AND DETAILS.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL8393_R8_AE_NSSRn 2023 FL 8393 REPORTS AND DETAILS.pdf Created by Independent Third Party: Yes |
|
|
| 8393.10 |
PBR-HVHZ |
26 Ga. PBR Roof Panel over 1 x 4 Wood Purlins over 15/32" Plywood |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-151.7PSF Other: Main Field-Pressure: -100.5 psf @ 12"-12"-12" fastener pattern @ 24" o.c. fastener spacing. Preimeter and Corner Pressure: -151.75 psf @ 7"-5"-7"-5"-7"-5" fastener patter @ 12" o.c. fastener spacing. Install per manufacturers details and in compliance with Current FBC .
For use in HVHZ Zones. |
Installation Instructions FL8393_R8_II_NSSRn 2023 FL 8393 REPORTS AND DETAILS.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL8393_R8_AE_NSSRn 2023 FL 8393 REPORTS AND DETAILS.pdf Created by Independent Third Party: Yes |
|
|
| 8393.11 |
RIB- HVHZ |
26 Ga. 3/4" Rib Roof panel over 15/32" plywood |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-159.25 Other: Main Field Pressure: -71.75 psf @ 9"-9"-9"-9" fastener pattern @ 24" o.c. fastener spacing. Perimeter and Corner Pressure:
159.25 psf @ 6.5"-2.5"-6.5"-2.5"-6.5"-2.5"-6.5"-2.5" fastener pattern 12" o.c. fastener spacing. Install per manufacturers details and in compliance with Current FBC .
For use in HVHZ Zones. |
Installation Instructions FL8393_R8_II_NSSRn 2023 FL 8393 REPORTS AND DETAILS.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL8393_R8_AE_NSSRn 2023 FL 8393 REPORTS AND DETAILS.pdf Created by Independent Third Party: Yes |
|
|
| 8393.12 |
RIB-HVHZ |
26 Ga. 3/4" Rib Roof panel over 1 x 4 Wood Purlins over 15/32" Plywood |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-164.25 Other: Uplift/Main Field Pressure:
-106.75 psf @ 9"-9"-9"-9" fastener pattern @ 24" o.c. fastener spacing. Perimeter and Corner Pressure: -164.25 psf @ 9"-9"-9"-9" fastener pattern 12" o.c. fastener spacing. Install per manufacturers details and in compliance with Current FBC .
For use in HVHZ Zones.
|
Installation Instructions FL8393_R8_II_NSSRn 2023 FL 8393 REPORTS AND DETAILS.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL8393_R8_AE_NSSRn 2023 FL 8393 REPORTS AND DETAILS.pdf Created by Independent Third Party: Yes |
|
|
| 8393.13 |
Snap Lock-HVHZ (DISCONTINUED) |
1" Snap Lock 24 Ga. 17" Wide Roof Panel over 15/32" Plywood |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-131.0PSF Other: -67.3 psf @ 24" o.c. clip spacing. -131.0 psf @ 6" o.c. clip spacing. Install per manufacturers details and in compliance with Current FBC.
For use in HVHZ Zones. |
Installation Instructions FL8393_R8_II_NSSRn 2023 FL 8393 REPORTS AND DETAILS.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL8393_R8_AE_NSSRn 2023 FL 8393 REPORTS AND DETAILS.pdf Created by Independent Third Party: Yes |