Product Approval Menu > Application Detail
 
FL # FL8393-R8
Application Type Revision
Code Version 2023
Application Status Approved
 
Comments
Archived
 
Product Manufacturer MarlynMetals, Incorporated
Address/Phone/Email 6808 Harney Rd
Tampa, FL 33610
(813) 621-1375
rryanj@marlynsteel.com
 
Authorized Signature Rick James
flvalidation@yahoo.com
 
Technical Representative
Address/Phone/Email
 
Quality Assurance Representative
Address/Phone/Email
 
Category Roofing
Subcategory Metal Roofing
 
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Evaluation Report - Hardcopy Received
 
Florida Engineer or Architect Name who developed the Evaluation Report Locke Bowden
Florida License PE-49704
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 11/14/2027
Validated By Steven M. Urich, PE
  Validation Checklist - Hardcopy Received
 
Certificate of Independence FL8393_R8_COI_SS CERTIFICATE OF INDEPENDENCE.pdf
 
Referenced Standard and Year (of Standard)
StandardYear
FM 44711992
TAS 1002023
TAS 1252003
UL 18972015
UL 5802006
 
Equivalence of Product Standards
Certified By

 
Sections from the Code
 
 
 
Product Approval Method Method 1 Option D
 
Date Submitted 04/30/2024
Date Validated 05/06/2024
Date Pending FBC Approval 05/12/2024
Date Approved 06/18/2024
Date Revised 09/26/2026
 
Summary of Products
FL # Model, Number or Name Description
8393.1 1.0 NS (DISCONTINED) 1.0 NS 24 Ga. 16" Coverage Roof Panel over 19/32" SEALED Plywood
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-52.5psf
 Other: -52.5 psf @ 16" o.c. fastener spacing. Install per manufacturers details and in compliance with Current FBC Not for use in HVHZ Zones.
Installation Instructions
 FL8393_R8_II_NSSRn 2023 FL 8393 REPORTS AND DETAILS.pdf
 Verified By: Locke Bowden, P.E. 49704
 Created by Independent Third Party: Yes
Evaluation Reports
 FL8393_R8_AE_NSSRn 2023 FL 8393 REPORTS AND DETAILS.pdf
 Created by Independent Third Party: Yes
8393.2 1.5 NS (DISCONTINUED) 1.5 NS 24 Ga. 14 1/2" Coverage Roof Panel over 19/32" Plywood
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-52.5 psf
 Other: -52.5 psf @ 18" o.c. fastener spacing. Install per manufacturers details and in compliance with Current FBC . Not for use in HVHZ Zones.
Installation Instructions
 FL8393_R8_II_NSSRn 2023 FL 8393 REPORTS AND DETAILS.pdf
 Verified By: Locke Bowden, P.E. 49704
 Created by Independent Third Party: Yes
Evaluation Reports
 FL8393_R8_AE_NSSRn 2023 FL 8393 REPORTS AND DETAILS.pdf
 Created by Independent Third Party: Yes
8393.3 5V Crimp Minimum 24 Ga. 5V Crimp Roof Panel over 1X4 Purlins over 15/32" and 19/32" Plywood
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-108.5psf
 Other: -108.5 psf @ 12" o.c. fasterner spacing -156.5 psf @ 6" fastener spacing over 1X4 purlins over min. 15/32" Plywood for existing construction and min. 19/32" Plywood for new construction Install per manufacturers details and in compliance with Current FBC for use in HVHZ and NON-HVHZ Zones.
Installation Instructions
 FL8393_R8_II_NSSRn 2023 FL 8393 REPORTS AND DETAILS.pdf
 Verified By: Locke Bowden, P.E. 49704
 Created by Independent Third Party: Yes
Evaluation Reports
 FL8393_R8_AE_NSSRn 2023 FL 8393 REPORTS AND DETAILS.pdf
 Created by Independent Third Party: Yes
8393.4 5V Crimp 26 Ga. 5V Crimp Roof Panel over 19/32" SEALED Plywood
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-52.5psf
 Other: -52.5 psf @ 36" o.c. fastener spacing. Fastener pattern 9"-2"-9". Install per manufacturers details in compliance with Current FBC . Not for use in HVHZ Zones.
Installation Instructions
 FL8393_R8_II_NSSRn 2023 FL 8393 REPORTS AND DETAILS.pdf
 Verified By: Locke Bowden, P.E. 49704
 Created by Independent Third Party: Yes
Evaluation Reports
 FL8393_R8_AE_NSSRn 2023 FL 8393 REPORTS AND DETAILS.pdf
 Created by Independent Third Party: Yes
8393.5 5V Crimp-HVHZ 5V Crimp 24 Ga. Roof Panel over 1X4 purlins over 15/32" and 19/32" SEALED Plywood
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: No
 Impact Resistant: N/A
 Design Pressure: +N/A/-108.5psf
 Other: -108.5 psf @ 12"o.c. fastener spacing. -156.5 psf @ 6" o.c. fastener spacing over 1X4 purlins over min. 15/32" plywood for existing construction and min.19/32" Plywood for new construction Install per manufacturers details and in compliance with Current FBC . for use in HVHZ and NON-HVHZ Zones.
Installation Instructions
 FL8393_R8_II_NSSRn 2023 FL 8393 REPORTS AND DETAILS.pdf
 Verified By: Locke Bowden, P.E. 49704
 Created by Independent Third Party: Yes
Evaluation Reports
 FL8393_R8_AE_NSSRn 2023 FL 8393 REPORTS AND DETAILS.pdf
 Created by Independent Third Party: Yes
8393.6 5V Crimp-HVHZ 26 Ga. 5V Crimp Roof Panel over 15/32" Plywood
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-156.5PSF
 Other: -108.5PSF @12" o.c. fastener spacing. -156.5 PSF @ 6" o.c. fastener spacing. Min. 15/32" plywood for existing construction and min. 19/32" for new construction. Install per manufacturers details and in compliance with Current FBC . For use in HVHZ Zones.
Installation Instructions
 FL8393_R8_II_NSSRn 2023 FL 8393 REPORTS AND DETAILS.pdf
 Verified By: Locke Bowden, P.E. 49704
 Created by Independent Third Party: Yes
Evaluation Reports
 FL8393_R8_AE_NSSRn 2023 FL 8393 REPORTS AND DETAILS.pdf
 Created by Independent Third Party: Yes
8393.7 Mar-Rib Mar-Rib 29 Ga. Roof Panel over 15/32" Plywood
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-52.5psf
 Other: -52.5 psf @ 12" o.c. fastener pattern 9"-9"-9"-9". Install per manufactuers details and in compliance with Current FBC . Not for use in HVHZ Zones.
Installation Instructions
 FL8393_R8_II_NSSRn 2023 FL 8393 REPORTS AND DETAILS.pdf
 Verified By: Locke Bowden, P.E. 49704
 Created by Independent Third Party: Yes
Evaluation Reports
 FL8393_R8_AE_NSSRn 2023 FL 8393 REPORTS AND DETAILS.pdf
 Created by Independent Third Party: Yes
8393.8 Mar-Rib Mar-Rib 29 Ga. Roof Panel over 19/32" SEALED Plywood or 2x4 Wood Lathing
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-52.5psf
 Other: -52.5 psf @ 24" o.c. fastener pattern 9"-9"-9"-9". Install per manufacturers details and in compliance with Current FBC . Not for use in HVHZ Zones.
Installation Instructions
 FL8393_R8_II_NSSRn 2023 FL 8393 REPORTS AND DETAILS.pdf
 Verified By: Locke Bowden, P.E. 49704
 Created by Independent Third Party: Yes
Evaluation Reports
 FL8393_R8_AE_NSSRn 2023 FL 8393 REPORTS AND DETAILS.pdf
 Created by Independent Third Party: Yes
8393.9 PBR-HVHZ 26 Ga. PBR Roof Panel over 15/32" plywood
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-154.7psf
 Other: Main Field-Pressure: -60.5 psf @ 12"-12"-12" fastener pattern @ 24" o.c. fastener spacing. Preimeter and Corner Pressure: -154.75 psf @ 7"-5"-7"-5"-7"-5" fastener patter @ 12" o.c. fastener spacing. Install per manufacturers details and in compliance with Current FBC . For use in HVHZ Zones.
Installation Instructions
 FL8393_R8_II_NSSRn 2023 FL 8393 REPORTS AND DETAILS.pdf
 Verified By: Locke Bowden, P.E. 49704
 Created by Independent Third Party: Yes
Evaluation Reports
 FL8393_R8_AE_NSSRn 2023 FL 8393 REPORTS AND DETAILS.pdf
 Created by Independent Third Party: Yes
8393.10 PBR-HVHZ 26 Ga. PBR Roof Panel over 1 x 4 Wood Purlins over 15/32" Plywood
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-151.7PSF
 Other: Main Field-Pressure: -100.5 psf @ 12"-12"-12" fastener pattern @ 24" o.c. fastener spacing. Preimeter and Corner Pressure: -151.75 psf @ 7"-5"-7"-5"-7"-5" fastener patter @ 12" o.c. fastener spacing. Install per manufacturers details and in compliance with Current FBC . For use in HVHZ Zones.
Installation Instructions
 FL8393_R8_II_NSSRn 2023 FL 8393 REPORTS AND DETAILS.pdf
 Verified By: Locke Bowden, P.E. 49704
 Created by Independent Third Party: Yes
Evaluation Reports
 FL8393_R8_AE_NSSRn 2023 FL 8393 REPORTS AND DETAILS.pdf
 Created by Independent Third Party: Yes
8393.11 RIB- HVHZ 26 Ga. 3/4" Rib Roof panel over 15/32" plywood
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-159.25
 Other: Main Field Pressure: -71.75 psf @ 9"-9"-9"-9" fastener pattern @ 24" o.c. fastener spacing. Perimeter and Corner Pressure: 159.25 psf @ 6.5"-2.5"-6.5"-2.5"-6.5"-2.5"-6.5"-2.5" fastener pattern 12" o.c. fastener spacing. Install per manufacturers details and in compliance with Current FBC . For use in HVHZ Zones.
Installation Instructions
 FL8393_R8_II_NSSRn 2023 FL 8393 REPORTS AND DETAILS.pdf
 Verified By: Locke Bowden, P.E. 49704
 Created by Independent Third Party: Yes
Evaluation Reports
 FL8393_R8_AE_NSSRn 2023 FL 8393 REPORTS AND DETAILS.pdf
 Created by Independent Third Party: Yes
8393.12 RIB-HVHZ 26 Ga. 3/4" Rib Roof panel over 1 x 4 Wood Purlins over 15/32" Plywood
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-164.25
 Other: Uplift/Main Field Pressure: -106.75 psf @ 9"-9"-9"-9" fastener pattern @ 24" o.c. fastener spacing. Perimeter and Corner Pressure: -164.25 psf @ 9"-9"-9"-9" fastener pattern 12" o.c. fastener spacing. Install per manufacturers details and in compliance with Current FBC . For use in HVHZ Zones.
Installation Instructions
 FL8393_R8_II_NSSRn 2023 FL 8393 REPORTS AND DETAILS.pdf
 Verified By: Locke Bowden, P.E. 49704
 Created by Independent Third Party: Yes
Evaluation Reports
 FL8393_R8_AE_NSSRn 2023 FL 8393 REPORTS AND DETAILS.pdf
 Created by Independent Third Party: Yes
8393.13 Snap Lock-HVHZ (DISCONTINUED) 1" Snap Lock 24 Ga. 17" Wide Roof Panel over 15/32" Plywood
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-131.0PSF
 Other: -67.3 psf @ 24" o.c. clip spacing. -131.0 psf @ 6" o.c. clip spacing. Install per manufacturers details and in compliance with Current FBC. For use in HVHZ Zones.
Installation Instructions
 FL8393_R8_II_NSSRn 2023 FL 8393 REPORTS AND DETAILS.pdf
 Verified By: Locke Bowden, P.E. 49704
 Created by Independent Third Party: Yes
Evaluation Reports
 FL8393_R8_AE_NSSRn 2023 FL 8393 REPORTS AND DETAILS.pdf
 Created by Independent Third Party: Yes
 
Back   Next
 