| 8393.1 |
5V Crimp - HVHZ |
26 Ga. 5V Crimp Roof Panel over 15/32" SEALED Plywood (existing) 19/32" (new) SEALED Plywood |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-156.5psf Other: -108.5PSF @12" o.c. fastener spacing. -156.5 PSF @ 6" o.c. fastener spacing. Min. 15/32" plywood for existing construction and min. 19/32" for new construction. Install per manufacturers details and in compliance with Current FBC . For use in HVHZ Zones |
Installation Instructions FL8393_R9_II_SSNEW 2026 FL 8393 REPORTS AND DETAILS.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL8393_R9_AE_SSNEW 2026 FL 8393 REPORTS AND DETAILS.pdf Created by Independent Third Party: Yes |
|
|
| 8393.2 |
5V Crimp - NON HVHZ |
5V Crimp 26GA over 19/32" Plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-52.5psf Other: -52.5 psf @ 9"- 2"- 9" fastener pattern @ 36" o.c. Install per manufacturers details and in compliance with Current FBC . Not For use in HVHZ Zones |
Installation Instructions FL8393_R9_II_SSNEW 2026 FL 8393 REPORTS AND DETAILS.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL8393_R9_AE_SSNEW 2026 FL 8393 REPORTS AND DETAILS.pdf Created by Independent Third Party: Yes |
|
|
| 8393.3 |
5V Crimp - NON HVHZ |
5V Crimp 29GA over 15/32" Plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-52.5psf Other: -52.5 psf @ 12"- 8" fastener pattern @ 12" o.c. Install per manufacturers details and in compliance with Current FBC . Not For use in HVHZ Zones |
Installation Instructions FL8393_R9_II_SSNEW 2026 FL 8393 REPORTS AND DETAILS.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL8393_R9_AE_SSNEW 2026 FL 8393 REPORTS AND DETAILS.pdf Created by Independent Third Party: Yes |
|
|
| 8393.4 |
Mar-Rib |
Mar-Rib 29GA over 15/32" Plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-52.5psf Other: -52.5 psf @ 9"- 9"- 9"- 9" fastener spacing. -@ 12" o.c. fastener over min. 15/32" plywood Install per manufacturers details and in compliance with Current FBC . for use NON-HVHZ Zones. |
Installation Instructions FL8393_R9_II_SSNEW 2026 FL 8393 REPORTS AND DETAILS.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL8393_R9_AE_SSNEW 2026 FL 8393 REPORTS AND DETAILS.pdf Created by Independent Third Party: Yes |
|
|
| 8393.5 |
Mar-Rib |
29 GA Mar-Rib panel over 19/32" Plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-52.5PSF Other: -52.5PSF @9"- 9"- 9"- 9" o.c. fastener spacing. @ 24" o.c. Install per manufacturers details and in compliance with Current FBC .
Not For use in HVHZ Zones. |
Installation Instructions FL8393_R9_II_SSNEW 2026 FL 8393 REPORTS AND DETAILS.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL8393_R9_AE_SSNEW 2026 FL 8393 REPORTS AND DETAILS.pdf Created by Independent Third Party: Yes |
|
|
| 8393.6 |
PBR-HVHZ |
PBR 26GA over 15/32" Plywood |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-154.7psf Other: -60.6 psf @ 12"- 12"- 12" fastener pattern @ 24" o.c. -154.75 psf @ 7"- 5"- 7"- 5"- 7"- 5" @12" o.c.. Install per manufactuers details and in compliance with Current FBC .
Not for use in HVHZ Zones. |
Installation Instructions FL8393_R9_II_SSNEW 2026 FL 8393 REPORTS AND DETAILS.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL8393_R9_AE_SSNEW 2026 FL 8393 REPORTS AND DETAILS.pdf Created by Independent Third Party: Yes |
|
|
| 8393.7 |
PBR-HVHZ |
PBR 26GA over 1x4 Wood Purlins over Plywood |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-151.7psf Other: -100.5 psf @ 12"- 12"- 12" fastener pattern @ 24" o.c. -151.75 psf @ 7"- 5"- 7"- 5"- 7"- 5" @ 12" o.c. Install per manufacturers details and in compliance with Current FBC . for use in HVHZ Zones. |
Installation Instructions FL8393_R9_II_SSNEW 2026 FL 8393 REPORTS AND DETAILS.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL8393_R9_AE_SSNEW 2026 FL 8393 REPORTS AND DETAILS.pdf Created by Independent Third Party: Yes |
|
|
| 8393.8 |
RIB-HVHZ |
26 Ga. RIB Roof Panel over 15/32" plywood |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-159.2psf Other: Main Field-Pressure: -71.75 psf @ 9"- 9"- 9"- 9"" fastener pattern @ 24" o.c. fastener spacing. Preimeter and Corner Pressure:
-159.25 psf @ 6.5"- 2.5"- 6.5"- 2.5"- 6.5"- 2.5"- 6.5"- 2.5" fastener patter @ 12" o.c. fastener spacing. Install per manufacturers details and in compliance with Current FBC .
For use in HVHZ Zones. |
Installation Instructions FL8393_R9_II_SSNEW 2026 FL 8393 REPORTS AND DETAILS.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL8393_R9_AE_SSNEW 2026 FL 8393 REPORTS AND DETAILS.pdf Created by Independent Third Party: Yes |
|
|
| 8393.9 |
RIB-HVHZ |
3/4" Rib 26GA over 1x4 Wood Purlins over 15/32" Plywood |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-164.2PSF Other: Main Field-Pressure: -106.75 psf @ 9"- 9"- 9"- 9"" fastener pattern @ 24" o.c. fastener spacing. Preimeter and Corner Pressure: -164.25 psf @ 9"- 9"- 9"- 9" fastener patter @ 12" o.c. fastener spacing. Install per manufacturers details and in compliance with Current FBC .
For use in HVHZ Zones. |
Installation Instructions FL8393_R9_II_SSNEW 2026 FL 8393 REPORTS AND DETAILS.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL8393_R9_AE_SSNEW 2026 FL 8393 REPORTS AND DETAILS.pdf Created by Independent Third Party: Yes |