| 29669.1 |
01: Min. 26 Ga. Super Pro 5V Roof Panel |
Min. 26 Ga. Super Pro 5V Roof Panel over 15/32" Plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-198.5 Other: -63.5 psf at 24" o.c. | -198.5 psf at 6" o.c. |
Installation Instructions FL29669_R4_II_26ga_SuperPro_5V_plywood.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL29669_R4_AE_26ga_SuperPro_5V_plywood.pdf Created by Independent Third Party: Yes |
|
|
| 29669.2 |
02: Min. 26 Ga. Super Pro 5V Roof Panel |
Min. 26 Ga. Super Pro 5V Roof Panel over 1x4 Wood Purlins over 15/32" Plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-153.5 Other: -78.5 psf at 24" o.c. | -153.5 psf at 12" o.c. |
Installation Instructions FL29669_R4_II_26ga_SuperPro_5V_1x4.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL29669_R4_AE_26ga_SuperPro_5V_1x4.pdf Created by Independent Third Party: Yes |
|
|
| 29669.3 |
03: 032 (nom) Super Pro 5 Rib Roof Panel |
0.032" (nominal) or thicker aluminum Super Pro 5 Rib panel over 15/32" (min) plywood. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-123.5 Other: -71 psf at 24" o.c. | 123.5 psf at 6" o.c. |
Installation Instructions FL29669_R4_II_032_SuperPro_Plywood.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL29669_R4_AE_032_SuperPro_Plywood.pdf Created by Independent Third Party: Yes |