| 16674.1 |
A. Design Pro / Smooth Pro (F-3500) Fiberglass |
Inswing / Outswing Door 1 Panel 37.5" x 97.93" Opaque |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +50/-50 Other: Anchors within 3000 ft of the coast must comply with section 1711 of the current FBC. |
Certification Agency Certificate FL16674_R21_C_CAC_NI011919-R19.pdf Quality Assurance Contract Expiration Date 03/30/2032 Installation Instructions FL16674_R21_II_D1000186 - Design Pro Smooth Pro (F-3500) Fiberglass Swinging Door ISW-OSW 6-8 - 8-0 1P O-WZ3 FBC Installs_5-1-25 DSS.pdf Verified By: Micah Swartz, P.E. 93573 Created by Independent Third Party: Yes Evaluation Reports FL16674_R21_AE_SCE 25-04021 - 16674.1 Calcs R2 DSS.pdf Created by Independent Third Party: Yes |
|
|
| 16674.2 |
B. Design Pro / Smooth Pro (F-3500) Fiberglass |
Inswing / Outswing Door 1 Panel 37.5" x 97.93" Glazed |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +50/-50 Other: Anchors within 3000 ft of the coast must comply with section 1711 of the current FBC. |
Certification Agency Certificate FL16674_R21_C_CAC_NI011918-R18.pdf Quality Assurance Contract Expiration Date 03/30/2032 Installation Instructions FL16674_R21_II_D1000182 - Design Pro Smooth Pro (F-3500) Fiberglass Swinging Door ISW-OSW 6-8 - 8-0 1P G-WZ3 FBC Installs_5-1-25 DSS.pdf Verified By: Micah Swartz, P.E. 93573 Created by Independent Third Party: Yes Evaluation Reports FL16674_R21_AE_SCE 25-04022 - 16674.2 Calcs R2 DSS.pdf Created by Independent Third Party: Yes |
|
|
| 16674.3 |
C. Design Pro / Smooth Pro (F-3500) Fiberglass |
Inswing / Outswing Door 2 Panel XX 74" x 97.93" Opaque |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +50/-50 Other: Anchors within 3000 ft of the coast must comply with section 1711 of the current FBC. |
Certification Agency Certificate FL16674_R21_C_CAC_NI011916-R19.pdf Quality Assurance Contract Expiration Date 03/30/2032 Installation Instructions FL16674_R21_II_D1000186 - Design Pro Smooth Pro (F-3500) Fiberglass Swinging Door ISW-OSW 6-8 - 8-0 2P O-WZ3 FBC Installs_5-1-25 DSS.pdf Verified By: Micah Swartz, P.E. 93573 Created by Independent Third Party: Yes Evaluation Reports FL16674_R21_AE_SCE 25-04023 - 16674.3 Calcs R2 DSS.pdf Created by Independent Third Party: Yes |
|
|
| 16674.4 |
D. Design Pro / Smooth Pro (F-3500) Fiberglass |
Inswing / Outswing Door 2 Panel XX 74" x 97.93" Glazed |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +50/-50 Other: Anchors within 3000 ft of the coast must comply with section 1711 of the current FBC. |
Certification Agency Certificate FL16674_R21_C_CAC_NI011917.01-R16.pdf Quality Assurance Contract Expiration Date 03/30/2032 Installation Instructions FL16674_R21_II_D1000182 - Design Pro Smooth Pro (F-3500) Fiberglass Swinging Door ISW-OSW 6-8 - 8-0 2P G-WZ3 FBC Installs_5-1-25 DSS.pdf Verified By: Micah Swartz, P.E. 93573 Created by Independent Third Party: Yes Evaluation Reports FL16674_R21_AE_SCE 25-04024 - 16674.4 Calcs R2 DSS.pdf Created by Independent Third Party: Yes |
|
|
| 16674.5 |
E. Design Pro / Smooth Pro (F-3500) Fiberglass |
Inswing / Outswing Door Sidelites 3 Panel OXO 112.12" x 97.93" Opaque |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: 112.12" x 81.93" - DP50
112.12" x 97.93" - DP45.
Anchors within 3000 ft of the coast must comply with section 1711 of the current FBC. |
Certification Agency Certificate FL16674_R21_C_CAC_NI011922-R20.pdf Quality Assurance Contract Expiration Date 03/30/2032 Installation Instructions FL16674_R21_II_D1000186 - Design Pro Smooth Pro (F-3500) Fiberglass Swinging Door ISW-OSW 6-8 - 8-0 3P OXO O-WZ3 FBC Installs_5-1-25 DSS.pdf Verified By: Micah Swartz, P.E. 93573 Created by Independent Third Party: Yes Evaluation Reports FL16674_R21_AE_SCE 25-04025 - 16674.5 Calcs R3 DSS.pdf Created by Independent Third Party: Yes |
|
|
| 16674.6 |
F. Design Pro / Smooth Pro (F-3500) Fiberglass |
Inswing / Outswing Door Sidelites 3 Panel OXO 112.12" x 97.93" Glazed |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: 112.12" x 81.93" - DP50 112.12" x 97.93" - DP45
Anchors within 3000 ft of the coast must comply with section 1711 of the current FBC. |
Certification Agency Certificate FL16674_R21_C_CAC_NI013412-R10.pdf Quality Assurance Contract Expiration Date 03/30/2032 Installation Instructions FL16674_R21_II_D1000182 - Design Pro Smooth Pro (F-3500) Fiberglass Swinging Door ISW-OSW 6-8 - 8-0 3P OXO G-WZ3 FBC Installs_5-1-25 DSS.pdf Verified By: Micah Swartz, P.E. 93573 Created by Independent Third Party: Yes Evaluation Reports FL16674_R21_AE_SCE 25-04026 - 16674.6 Calcs R3 DSS.pdf Created by Independent Third Party: Yes |
|
|
| 16674.7 |
G. Design Pro / Smooth Pro (F-3500) Fiberglass |
Inswing / Outswing Door Sidelites 4 Panel OXXO 148.75" x 97.93" Opaque |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: 148.75" x 81.93" - DP50
148.75" x 97.93" - DP45
Anchors within 3000 ft of the coast must comply with section 1711 of the current FBC. |
Certification Agency Certificate FL16674_R21_C_CAC_NI011914.01-R19.pdf Quality Assurance Contract Expiration Date 03/30/2032 Installation Instructions FL16674_R21_II_D1000186 - Design Pro Smooth Pro (F-3500) Fiberglass Swinging Door ISW-OSW 6-8 - 8-0 4P OXXO O-WZ3 FBC Installs_5-1-25 DSS.pdf Verified By: Micah Swartz, P.E. 93573 Created by Independent Third Party: Yes Evaluation Reports FL16674_R21_AE_SCE 25-04027 - 16674.7 Calcs R3 DSS.pdf Created by Independent Third Party: Yes |
|
|
| 16674.8 |
H. Design Pro / Smooth Pro (F-3500) Fiberglass |
Inswing / Outswing Door Sidelites 4 Panel OXXO 148.75" x 97.93" Glazed |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: 144.75" x 81.93" - DP50
144.75" x 97.93" - DP45
Anchors within 3000 ft of the coast must comply with section 1711 of the current FBC. |
Certification Agency Certificate FL16674_R21_C_CAC_NI011915.01-R17.pdf Quality Assurance Contract Expiration Date 03/30/2032 Installation Instructions FL16674_R21_II_D1000182 - Design Pro Smooth Pro (F-3500) Fiberglass Swinging Door ISW-OSW 6-8 - 8-0 4P OXXO G-WZ3 FBC Installs_5-1-25 DSS.pdf Verified By: Micah Swartz, P.E. 93573 Created by Independent Third Party: Yes Evaluation Reports FL16674_R21_AE_SCE 25-04028 - 16674.8 Calcs R3 DSS.pdf Created by Independent Third Party: Yes |