| 26035.1 |
350 Series Outswing Casement |
2-1/2" Frame Depth. The windows are impact resistant but have not been evaluated for use in high velocity hurricane zones. Impact Rating +60/-60 psf. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +60/-60 Other: |
Installation Instructions FL26035_R4_II_350 Series Casement Impact R2 2023 FBC.pdf Verified By: Intertek Testing Services NA, Inc. Created by Independent Third Party: Evaluation Reports FL26035_R4_AE_350 SERIES CASEMENT IMPACT - R1.pdf Created by Independent Third Party: Yes |
|
|
| 26035.2 |
350 Series Outswing Casement |
2-1/2" Frame Depth. The windows are impact resistant but have not been evaluated for use in high velocity hurricane zones. Impact Rating +70/-70 psf. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +70/-70 Other: |
Installation Instructions FL26035_R4_II_350 Series Casement Impact R2 2023 FBC.pdf Verified By: Intertek Testing Services NA, Inc. Created by Independent Third Party: Evaluation Reports FL26035_R4_AE_350 SERIES CASEMENT IMPACT - R1.pdf Created by Independent Third Party: Yes |
|
|
| 26035.3 |
350 Series Outswing Casement |
2-1/2" Frame Depth. The windows are not impact resistant and have not been evaluated for use in high velocity hurricane zones. Rating +70/-70 psf. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +70/-70 Other: |
Installation Instructions FL26035_R4_II_350 Series Casement non-Impact R2 2023 FBC.pdf Verified By: Intertek Testing Services NA, Inc. Created by Independent Third Party: Evaluation Reports FL26035_R4_AE_350 SERIES CASEMENT NON IMPACT.pdf Created by Independent Third Party: Yes |
|
|
| 26035.4 |
350 Series Outswing Casement - Fixed |
2-1/2" Frame Depth. The windows are impact resistant but have not been evaluated for use in high velocity hurricane zones. Impact Rating +60/-60 psf. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +60/-60 Other: |
Installation Instructions FL26035_R4_II_350 Series Casement Impact R2 2023 FBC.pdf Verified By: Intertek Testing Services NA, Inc. Created by Independent Third Party: Evaluation Reports FL26035_R4_AE_350 SERIES CASEMENT IMPACT - R1.pdf Created by Independent Third Party: Yes |
|
|
| 26035.5 |
350 Series Outswing Casement - Fixed |
2-1/2" Frame Depth. The windows are not impact resistant and have not been evaluated for use in high velocity hurricane zones. Rating +70/-70 psf. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +70/-70 Other: |
Installation Instructions FL26035_R4_II_350 Series Casement non-Impact R2 2023 FBC.pdf Verified By: Intertek Testing Services NA, Inc. Created by Independent Third Party: Evaluation Reports FL26035_R4_AE_350 SERIES CASEMENT NON IMPACT.pdf Created by Independent Third Party: Yes |
|
|
| 26035.6 |
350 Series Outswing Casement - Fixed - Outswing Casement |
2-1/2" Frame Depth. The windows are impact resistant but have not been evaluated for use in high velocity hurricane zones. Impact Rating +60/-60 psf. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +60/-60 Other: |
Installation Instructions FL26035_R4_II_350 Series Casement Impact R2 2023 FBC.pdf Verified By: Intertek Testing Services NA, Inc. Created by Independent Third Party: Evaluation Reports FL26035_R4_AE_350 SERIES CASEMENT IMPACT - R1.pdf Created by Independent Third Party: Yes |
|
|
| 26035.7 |
350 Series Twin Outswing Casement |
2-1/2" Frame Depth. The windows are impact resistant but have not been evaluated for use in high velocity hurricane zones. Impact Rating +60/-60 psf. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +60/-60 Other: |
Installation Instructions FL26035_R4_II_350 Series Casement Impact R2 2023 FBC.pdf Verified By: Intertek Testing Services NA, Inc. Created by Independent Third Party: Evaluation Reports FL26035_R4_AE_350 SERIES CASEMENT IMPACT - R1.pdf Created by Independent Third Party: Yes |
|
|
| 26035.8 |
600 Series Outswing Casement |
3-1/2" Frame Depth. The windows are impact resistant but have not been evaluated for use in high velocity hurricane zones. Impact Rating +60/-60 psf. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +60/-60 Other: |
Installation Instructions FL26035_R4_II_600 Series Casement Impact R2 2023 FBC.pdf Verified By: Intertek Testing Services NA, Inc. Created by Independent Third Party: Evaluation Reports FL26035_R4_AE_600 SERIES CASEMENT IMPACT- R1.pdf Created by Independent Third Party: Yes |
|
|
| 26035.9 |
600 Series Outswing Casement |
3-1/2" Frame Depth. The windows are impact resistant but have not been evaluated for use in high velocity hurricane zones. Impact Rating +70/-70 psf. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +70/-70 Other: |
Installation Instructions FL26035_R4_II_600 Series Casement Impact R2 2023 FBC.pdf Verified By: Intertek Testing Services NA, Inc. Created by Independent Third Party: Evaluation Reports FL26035_R4_AE_600 SERIES CASEMENT IMPACT- R1.pdf Created by Independent Third Party: Yes |
|
|
| 26035.10 |
600 Series Outswing Casement |
3-1/2" Frame Depth. The windows are not impact resistant and have not been evaluated for use in high velocity hurricane zones. Rating +70/-70 psf. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +70/-70 Other: |
Installation Instructions FL26035_R4_II_600 Series Casement non-Impact R2 2023 FBC.pdf Verified By: Intertek Testing Services NA, Inc. Created by Independent Third Party: Evaluation Reports FL26035_R4_AE_600 SERIES CASEMENT NON IMPACT - R1.pdf Created by Independent Third Party: Yes |
|
|
| 26035.11 |
600 Series Outswing Casement - Fixed |
3-1/2" Frame Depth. The windows are impact resistant but have not been evaluated for use in high velocity hurricane zones. Impact Rating +60/-60 psf. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +60/-60 Other: |
Installation Instructions FL26035_R4_II_600 Series Casement Impact R2 2023 FBC.pdf Verified By: Intertek Testing Services NA, Inc. Created by Independent Third Party: Evaluation Reports FL26035_R4_AE_600 SERIES CASEMENT IMPACT- R1.pdf Created by Independent Third Party: Yes |
|
|
| 26035.12 |
600 Series Outswing Casement - Fixed |
3-1/2" Frame Depth. The windows are not impact resistant and have not been evaluated for use in high velocity hurricane zones. Rating +70/-70 psf. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +70/-70 Other: |
Installation Instructions FL26035_R4_II_600 Series Casement non-Impact R2 2023 FBC.pdf Verified By: Intertek Testing Services NA, Inc. Created by Independent Third Party: Evaluation Reports FL26035_R4_AE_600 SERIES CASEMENT NON IMPACT - R1.pdf Created by Independent Third Party: Yes |
|
|
| 26035.13 |
600 Series Outswing Casement - Fixed - Outswing Casement |
3-1/2" Frame Depth. The windows are impact resistant but have not been evaluated for use in high velocity hurricane zones. Impact Rating +60/-60 psf. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +60/-60 Other: |
Installation Instructions FL26035_R4_II_600 Series Casement Impact R2 2023 FBC.pdf Verified By: Intertek Testing Services NA, Inc. Created by Independent Third Party: Evaluation Reports FL26035_R4_AE_600 SERIES CASEMENT IMPACT- R1.pdf Created by Independent Third Party: Yes |
|
|
| 26035.14 |
600 Series Twin Outswing Casement |
3-1/2" Frame Depth. The windows are impact resistant but have not been evaluated for use in high velocity hurricane zones. Impact Rating +60/-60 psf. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +60/-60 Other: |
Installation Instructions FL26035_R4_II_600 Series Casement Impact R2 2023 FBC.pdf Verified By: Intertek Testing Services NA, Inc. Created by Independent Third Party: Evaluation Reports FL26035_R4_AE_600 SERIES CASEMENT IMPACT- R1.pdf Created by Independent Third Party: Yes |
|
|
| 26035.15 |
800 Series Outswing Casement |
2" Frame Depth. The windows are impact resistant but have not been evaluated for use in high velocity hurricane zones. Impact Rating +60/-60 psf. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +60/-60 Other: |
Installation Instructions FL26035_R4_II_800 Series Casement Impact R2 2023 FBC.pdf Verified By: Intertek Testing Services NA, Inc. Created by Independent Third Party: Evaluation Reports FL26035_R4_AE_800 SERIES CASEMENT IMPACT.pdf Created by Independent Third Party: Yes |
|
|
| 26035.16 |
800 Series Outswing Casement |
2" Frame Depth. The windows are impact resistant but have not been evaluated for use in high velocity hurricane zones. Impact Rating +70/-70 psf. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +70/-70 Other: |
Installation Instructions FL26035_R4_II_800 Series Casement Impact R2 2023 FBC.pdf Verified By: Intertek Testing Services NA, Inc. Created by Independent Third Party: Evaluation Reports FL26035_R4_AE_800 SERIES CASEMENT IMPACT.pdf Created by Independent Third Party: Yes |
|
|
| 26035.17 |
800 Series Outswing Casement |
2" Frame Depth. The windows are not impact resistant and have not been evaluated for use in high velocity hurricane zones. Rating +70/-70 psf. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +70/-70 Other: |
Installation Instructions FL26035_R4_II_800 Series Casement non-Impact R2 2023 FBC.pdf Verified By: Intertek Testing Services NA, Inc. Created by Independent Third Party: Evaluation Reports FL26035_R4_AE_800 SERIES CASEMENT NON IMPACT.pdf Created by Independent Third Party: Yes |
|
|
| 26035.18 |
800 Series Outswing Casement - Fixed |
2" Frame Depth. The windows are not impact resistant and have not been evaluated for use in high velocity hurricane zones. Rating +70/-70 psf. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +70/-70 Other: |
Installation Instructions FL26035_R4_II_800 Series Casement non-Impact R2 2023 FBC.pdf Verified By: Intertek Testing Services NA, Inc. Created by Independent Third Party: Evaluation Reports FL26035_R4_AE_800 SERIES CASEMENT NON IMPACT.pdf Created by Independent Third Party: Yes |
|
|
| 26035.19 |
800 Series Outswing Casement - Fixed |
2" Frame Depth. The windows are impact resistant but have not been evaluated for use in high velocity hurricane zones. Impact Rating +60/-60 psf. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +60/-60 Other: |
Installation Instructions FL26035_R4_II_800 Series Casement Impact R2 2023 FBC.pdf Verified By: Intertek Testing Services NA, Inc. Created by Independent Third Party: Evaluation Reports FL26035_R4_AE_800 SERIES CASEMENT IMPACT.pdf Created by Independent Third Party: Yes |
|
|
| 26035.20 |
800 Series Outswing Casement - Fixed - Outswing Casement |
2" Frame Depth. The windows are impact resistant but have not been evaluated for use in high velocity hurricane zones. Impact Rating +60/-60 psf. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +60/-60 Other: |
Installation Instructions FL26035_R4_II_800 Series Casement Impact R2 2023 FBC.pdf Verified By: Intertek Testing Services NA, Inc. Created by Independent Third Party: Evaluation Reports FL26035_R4_AE_800 SERIES CASEMENT IMPACT.pdf Created by Independent Third Party: Yes |