| 15998.1 |
7.2 Panel |
Max 36" wide, min 26 ga. through fastened panel |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-52.5 Other: UL Construction No. 244. Design uplift pressure for Class 90 = 52.5 psf and Class 30 = 22.5 psf. The required design wind loads shall be determined for each project. The maximum purlin spacing listed herein shall not be exceeded. All rational analysis computations shall be prepared by a qualified design professional, as required by Florida Building Code. |
Certification Agency Certificate FL15998_R4_C_CAC_UL244.pdf Quality Assurance Contract Expiration Date 12/31/2026 Installation Instructions FL15998_R4_II_UL244.pdf Verified By: UL LLC Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 15998.2 |
R or PBR Panel |
Max 36" wide, min 26 ga. through fastened panel |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-52.5 Other: UL Construction No. 30, 54, 79, 104, 112, 161, 167, 184 and 542. Design uplift pressure for Class 90 = 52.5 psf and Class 60 = 37.5 psf. The required design wind loads shall be determined for each project. The maximum purlin spacing listed herein shall not be exceeded. All rational analysis computations shall be prepared by a qualified design professional, as required by Florida Building Code. |
Certification Agency Certificate FL15998_R4_C_CAC_UL030.pdf FL15998_R4_C_CAC_UL054.pdf FL15998_R4_C_CAC_UL079.pdf FL15998_R4_C_CAC_UL104.pdf FL15998_R4_C_CAC_UL112.pdf FL15998_R4_C_CAC_UL161.pdf FL15998_R4_C_CAC_UL167.pdf FL15998_R4_C_CAC_UL184.pdf FL15998_R4_C_CAC_UL542.pdf Quality Assurance Contract Expiration Date 12/31/2026 Installation Instructions FL15998_R4_II_UL030.pdf FL15998_R4_II_UL054.pdf FL15998_R4_II_UL079.pdf FL15998_R4_II_UL104.pdf FL15998_R4_II_UL112.pdf FL15998_R4_II_UL161.pdf FL15998_R4_II_UL167.pdf FL15998_R4_II_UL184.pdf FL15998_R4_II_UL542.pdf Verified By: UL LLC Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 15998.3 |
U or PBU Panel |
Max 36" wide, min 26 ga. through fastened panel |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-52.5 Other: UL Construction No. 39. Design uplift pressure for Class 90 = 52.5 psf. The required design wind loads shall be determined for each project. The maximum purlin spacing listed herein shall not be exceeded. All rational analysis computations shall be prepared by a qualified design professional, as required by Florida Building Code. |
Certification Agency Certificate FL15998_R4_C_CAC_UL039.pdf Quality Assurance Contract Expiration Date 12/31/2026 Installation Instructions FL15998_R4_II_UL039.pdf Verified By: UL LLC Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |