| 41743.1 |
Master Rib |
29 Ga. (min) Steel Roof Panel, 3/4" Ribbed x 36" Wide, over 1/2" Plywood. Fastened 9" O.C. x 24" O.C. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-63.45 Other: Please see Test Report for Limits of Use. |
Installation Instructions FL41743_R1_II_Master Rib 29 gauge panel test report - plywood decking only - fastener pattern 1.pdf Verified By: Farabaugh Engineering and Testing, LLC Test Reports FL41743_R1_TR_Master Rib 29 gauge panel test report - plywood decking only - fastener pattern 1.pdf |
|
|
| 41743.2 |
Master Rib |
29 Ga. (min) Steel Roof Panel, 3/4" Ribbed x 36" Wide, over 1/2" Plywood. Fastened 9" O.C. typically, with an additional fastener at panel overlap, x 24" O.C. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-76.95 Other: Please see Installation Drawings for Limits of Use. |
Installation Instructions FL41743_R1_II_Master Rib 29 gauge panel test report - plywood decking only - fastener pattern 2.pdf Verified By: Farabaugh Engineering and Testing, LLC Test Reports FL41743_R1_TR_Master Rib 29 gauge panel test report - plywood decking only - fastener pattern 2.pdf |
|
|
| 41743.3 |
Master Rib |
29 Ga. (min) Steel Roof Panel, 3/4" Ribbed x 36" wide, over 1x4 Wood Purlins (spaced 24" O.C. max) over 1/2" Plywood. Fastened 9" O.C. x 24" O.C. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-78.5 Other: Please see Test Report for Limits of Use. |
Installation Instructions FL41743_R1_II_Master Rib 29 gauge panel test report - plywood decking and 1x4 strips - fastener pattern 1-3.pdf Verified By: Farabaugh Engineering and Testing, LLC Test Reports FL41743_R1_TR_Master Rib 29 gauge panel test report - plywood decking and 1x4 strips - fastener pattern 1-3.pdf |
|
|
| 41743.4 |
PBR Panel |
26 Ga. (min) Steel Roof Panel, 1 1/4" Ribbed x 36" Wide, over 16 Ga. (min) Steel Purlins spaced 60" O.C. max. Fastened 12" O.C. x 60" O.C. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +33.75/-32.5 Other: Please see Test Report for Limits of Use |
Installation Instructions FL41743_R1_II_p2827.01-450-44-r0.pdf Verified By: Architectural Testing, Inc. (an Intertek company) - West Palm Beach, FL Test Reports FL41743_R1_TR_p2827.01-450-44-r0.pdf |