| 41796.1 |
01: 032 1" Nailstrip on plywood |
Nominally 0.032" aluminum or thicker 1" nailstrip on 15/32" (min) plywood |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-175 Other: See evaluation report |
Installation Instructions FL41796_R0_II_32Al_nailstrip_100_plywood_a.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL41796_R0_AE_32Al_nailstrip_100_plywood_a.pdf Created by Independent Third Party: Yes |
|
|
| 41796.2 |
02: 032 1" Nailstrip on plywood |
Nominally 0.032" aluminum or thicker 1" nailstrip on 15/32" (min) plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-168.5 Other: See evaluation report |
Installation Instructions FL41796_R0_II_32Al_nailstrip_100_plywood_nonHVHZ_a.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL41796_R0_AE_32Al_nailstrip_100_plywood_nonHVHZ_a.pdf Created by Independent Third Party: Yes |
|
|
| 41796.3 |
03: 032 1" Nailstrip on plywood |
Nominally 0.032" aluminum or thicker 1" nailstrip on 15/32" (min) plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-86 Other: See evaluation report |
Installation Instructions FL41796_R0_II_32Al_nailstrip_100_plywood_nonHVHZ_b.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL41796_R0_AE_32Al_nailstrip_100_plywood_nonHVHZ_b.pdf Created by Independent Third Party: Yes |
|
|
| 41796.4 |
04: 032 1" Nailstrip on plywood |
Nominally 0.032" aluminum or thicker 1" nailstrip on 15/32" (min) plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-153.5 Other: See evaluation report |
Installation Instructions FL41796_R0_II_32Al_nailstrip_100_plywood_nonHVHZ_c.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL41796_R0_AE_32Al_nailstrip_100_plywood_nonHVHZ_c.pdf Created by Independent Third Party: Yes |
|
|
| 41796.5 |
05: 26ga 1" Nailstrip on plywood |
26ga (min) 1" nailstrip on 15/32" (min) plywood |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-116 Other: See evaluation report |
Installation Instructions FL41796_R0_II_26ga_nailstrip_100_plywood_a.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL41796_R0_AE_26ga_nailstrip_100_plywood_a.pdf Created by Independent Third Party: Yes |
|
|
| 41796.6 |
06: 26ga 1" Nailstrip on plywood |
26ga (min) 1" nailstrip on 15/32" (min) plywood |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-176 Other: See evaluation report |
Installation Instructions FL41796_R0_II_26ga_nailstrip_100_plywood_b.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL41796_R0_AE_26ga_nailstrip_100_plywood_b.pdf Created by Independent Third Party: Yes |
|
|
| 41796.7 |
07: 24ga 1" Nailstrip on plywood |
24ga (min) 1" nailstrip on 15/32" (min) plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-206 Other: See evaluation report |
Installation Instructions FL41796_R0_II_24ga_nailstrip_100_plywood_nonHVHZ_a.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL41796_R0_AE_24ga_nailstrip_100_plywood_nonHVHZ_a.pdf Created by Independent Third Party: Yes |
|
|
| 41796.8 |
08: 26ga 1" Nailstrip on plywood |
26ga (min) 1" nailstrip on 15/32" (min) plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-78.5 Other: See evaluation report |
Installation Instructions FL41796_R0_II_26ga_nailstrip_100_plywood_nonHVHZ_a.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL41796_R0_AE_26ga_nailstrip_100_plywood_nonHVHZ_a.pdf Created by Independent Third Party: Yes |
|
|
| 41796.9 |
09: 26ga 1" Nailstrip on plywood |
26ga (min) 1" nailstrip on 15/32" (min) plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-108.5 Other: See evaluation report |
Installation Instructions FL41796_R0_II_26ga_nailstrip_100_plywood_nonHVHZ_b.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL41796_R0_AE_26ga_nailstrip_100_plywood_nonHVHZ_b.pdf Created by Independent Third Party: Yes |
|
|
| 41796.10 |
10: 032 1.5" Nailstrip on plywood |
Nominally 0.032" aluminum or thicker 1.5" nailstrip on 15/32" (min) plywood |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-168.1 Other: See evaluation report |
Installation Instructions FL41796_R0_II_32Al_nailstrip_150_plywood_a.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL41796_R0_AE_32Al_nailstrip_150_plywood_a.pdf Created by Independent Third Party: Yes |
|
|
| 41796.11 |
11: 032 1.5" Nailstrip on plywood |
Nominally 0.032" aluminum or thicker 1.5" nailstrip on 15/32" (min) plywood |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-179.5 Other: See evaluation report |
Installation Instructions FL41796_R0_II_32Al_nailstrip_150_plywood_y.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL41796_R0_AE_32Al_nailstrip_150_plywood_y.pdf Created by Independent Third Party: Yes |
|
|
| 41796.12 |
12: 032 1.5" Nailstrip on plywood |
Nominally 0.032" aluminum or thicker 1.5" nailstrip on 15/32" (min) plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-168.5 Other: See evaluation report |
Installation Instructions FL41796_R0_II_32Al_nailstrip_150_plywood_nonHVHZ_a.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL41796_R0_AE_32Al_nailstrip_150_plywood_nonHVHZ_a.pdf Created by Independent Third Party: Yes |
|
|
| 41796.13 |
13: 24ga 1.5" Nailstrip on plywood |
24ga (min) 1.5" nailstrip on 15/32" (min) plywood |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-112.5 Other: See evaluation report |
Installation Instructions FL41796_R0_II_24ga_nailstrip_150_plywood_a.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL41796_R0_AE_24ga_nailstrip_150_plywood_a.pdf Created by Independent Third Party: Yes |
|
|
| 41796.14 |
14: 24ga 1.5" Nailstrip on plywood |
24ga (min) 1.5" nailstrip on 15/32" (min) plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-153.5 Other: See evaluation report |
Installation Instructions FL41796_R0_II_24ga_nailstrip_150_plywood_nonHVHZ_a.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL41796_R0_AE_24ga_nailstrip_150_plywood_nonHVHZ_a.pdf Created by Independent Third Party: Yes |
|
|
| 41796.15 |
15: 26ga 1.5" Nailstrip on plywood |
26ga (min) 1.5" nailstrip on 15/32" (min) plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-63.5 Other: See evaluation report |
Installation Instructions FL41796_R0_II_26ga_nailstrip_150_19in_plywood_nonHVHZ_a.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL41796_R0_AE_26ga_nailstrip_150_19in_plywood_nonHVHZ_a.pdf Created by Independent Third Party: Yes |