FL # FL18525-R0
Application Type New
Code Version 2014
Application Status Approved
 
Comments Public comment; Products .2, .3 and .4 there is no information regarding underlayment installation, or fire barriers as required by FBC 1518.
Archived
 
Product Manufacturer Mullets Aluminum
Address/Phone/Email 6345 McIntosh Rd
Sarasota, FL 34238
(941) 371-3502
flvalidation@yahoo.com
 
Authorized Signature Jay Coblentz
flvalidation@yahoo.com
 
Technical Representative
Address/Phone/Email
 
Quality Assurance Representative
Address/Phone/Email
 
Category Roofing
Subcategory Metal Roofing
 
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Evaluation Report - Hardcopy Received
 
Florida Engineer or Architect Name who developed the Evaluation Report Locke Bowden
Florida License PE-49704
Quality Assurance Entity Keystone Certifications, Inc.
Quality Assurance Contract Expiration Date 08/14/2026
Validated By Zachary R. Priest, P.E.
  Validation Checklist - Hardcopy Received
 
Certificate of Independence FL18525_R0_COI_MULLETS ALUMINUM.pdf
 
Referenced Standard and Year (of Standard)
StandardYear
TAS 1001995
UL 18972004
UL 5802006
 
Equivalence of Product Standards
Certified By

 
Sections from the Code
 
 
 
Product Approval Method Method 1 Option D
 
Date Submitted 09/01/2015
Date Validated 09/01/2015
Date Pending FBC Approval 09/08/2015
Date Approved 10/16/2015
Date Revised 02/14/2018
 
Summary of Products
FL # Model, Number or Name Description
18525.1 1.5 AL 0.032 MECHANICAL LOCK OVER 15/32" APA Plywood Grade C-D
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +n/a/-123psf
 Other: -123psf@ 6"o.c. -59.75psf@ 24"o.c. Install per manufacturers detail and in compliance w/FBC 2014. NOT FOR USE IN HVHZ.
Installation Instructions
 FL18525_R0_II_FL 18525 replace FL 8660 Mullets Aluminum.pdf
 FL18525_R0_II_MULLETS ALUMINUM.pdf
 Verified By: Locke Bowden, P.E. 49704
 Created by Independent Third Party: Yes
Evaluation Reports
 FL18525_R0_AE_MULLETS ALUMINUM.pdf
 Created by Independent Third Party: Yes
18525.2 1.5 MECHANICAL LOCK 24GA mechanical lock over 15/32" APA Plywood
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +n/a/--123psf
 Other: -123psf@ 6"o.c. -59.75psf@ 24"o.c. Install per manufacturers detail and in compliance w/FBC 2014. 19/32" APA plywood for HVHZ new construction. For use in HVHZ.
Installation Instructions
 FL18525_R0_II_MULLETS ALUMINUM.pdf
 Verified By: Locke Bowden, P.E. 49704
 Created by Independent Third Party: Yes
Evaluation Reports
 FL18525_R0_AE_MULLETS ALUMINUM.pdf
 Created by Independent Third Party: Yes
18525.3 1.5 NAIL STRIP 24GA OVER 15/32" APA PLYWOOD Install per manufacturers detail and in compliance w/FBC 2014. Use 19/32" APA Plywood for HVHZ new construction. For use in HVHZ.
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +n/a/--116psf
 Other: -116psf @ 6-1/2" 12"o.c. in pan spacing. -78.5psf@ 11"o.c. panel slot fastening. Install per manufacturers detail and in compliance with FBC 2014. For use in HVHZ.
Installation Instructions
 FL18525_R0_II_MULLETS ALUMINUM.pdf
 Verified By: Locke Bowden, P.E. 49704
 Created by Independent Third Party: Yes
Evaluation Reports
 FL18525_R0_AE_MULLETS ALUMINUM.pdf
 Created by Independent Third Party: Yes
18525.4 1.5 SNAP LOCK 24GA OVER 15/32" APA PLYWOOD
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +n/a/-116psf
 Other: -116pf @ 6"o.c. clip spacing 12"o.c -108psf fastening at 24"o.c. Install per manufacturers detail and in compliance w/FBC 2014. Use 19/32" APA Plywood for HVHZ new construction. For use in HVHZ.
Installation Instructions
 FL18525_R0_II_MULLETS ALUMINUM.pdf
 Verified By: Locke Bowden, P.E. 49704
 Created by Independent Third Party: Yes